Browsing by Author "Winkler, A."
Now showing 1 - 4 of 4
Results Per Page
Sort Options
- ItemCompact SAW aerosol generator(Heidelberg : Springer, 2017) Winkler, A.; Harazim, S.; Collins, D.J.; Brünig, R.; Schmidt, H.; Menzel, S.B.In this work, we discuss and demonstrate the principle features of surface acoustic wave (SAW) aerosol generation, based on the properties of the fluid supply, the acoustic wave field and the acoustowetting phenomena. Furthermore, we demonstrate a compact SAW-based aerosol generator amenable to mass production fabricated using simple techniques including photolithography, computerized numerical control (CNC) milling and printed circuit board (PCB) manufacturing. Using this device, we present comprehensive experimental results exploring the complexity of the acoustic atomization process and the influence of fluid supply position and geometry, SAW power and fluid flow rate on the device functionality. These factors in turn influence the droplet size distribution, measured here, that is important for applications including liquid chromatography, pulmonary therapies, thin film deposition and olfactory displays.
- ItemThe complexity of surface acoustic wave fields used for microfluidic applications(Amsterdam [u.a.] : Elsevier, 2020) Weser, R.; Winkler, A.; Weihnacht, M.; Menzel, S.; Schmidt, H.Using surface acoustic waves (SAW) for the agitation and manipulation of fluids and immersed particles or cells in lab-on-a-chip systems has been state of the art for several years. Basic tasks comprise fluid mixing, atomization of liquids as well as sorting and separation (or trapping) of particles and cells, e.g. in so-called acoustic tweezers. Even though the fundamental principles governing SAW excitation and propagation on anisotropic, piezoelectric substrates are well-investigated, the complexity of wave field effects including SAW diffraction, refraction and interference cannot be comprehensively simulated at this point of time with sufficient accuracy. However, the design of microfluidic actuators relies on a profound knowledge of SAW propagation, including superposition of multiple SAWs, to achieve the predestined functionality of the devices. Here, we present extensive experimental results of high-resolution analysis of the lateral distribution of the complex displacement amplitude, i.e. the wave field, alongside with the electrical S-parameters of the generating transducers. These measurements were carried out and are compared in setups utilizing travelling SAW (tSAW) excited by single interdigital transducer (IDT), standing SAW generated between two IDTs (1DsSAW, 1D acoustic tweezers) and between two pairs of IDTs (2DsSAW, 2D acoustic tweezers) with different angular alignment in respect to pure Rayleigh mode propagation directions and other practically relevant orientations. For these basic configurations, typically used to drive SAW-based microfluidics, the influence of common SAW phenomena including beam steering, coupling coefficient dispersion and diffraction on the resultant wave field is investigated. The results show how tailoring of the acoustic conditions, based on profound knowledge of the physical effects, can be achieved to finally realize a desired behavior of a SAW-based microacoustic-fluidic system. © 2020 Elsevier B.V.
- ItemConverse Magnetoelectric Composite Resonator for Sensing Small Magnetic Fields(London : Nature Publishing Group, 2019) Hayes, P.; Jovičević Klug, M.; Toxværd, S.; Durdaut, P.; Schell, V.; Teplyuk, A.; Burdin, D.; Winkler, A.; Weser, R.; Fetisov, Y.; Höft, M.; Knöchel, R.; McCord, J.; Quandt, E.Magnetoelectric (ME) thin film composites consisting of sputtered piezoelectric (PE) and magnetostrictive (MS) layers enable for measurements of magnetic fields passively, i.e. an AC magnetic field directly generates an ME voltage by mechanical coupling of the MS deformation to the PE phase. In order to achieve high field sensitivities a magnetic bias field is necessary to operate at the maximum piezomagnetic coefficient of the MS phase, harnessing mechanical resonances further enhances this direct ME effect size. Despite being able to detect very small AC field amplitudes, exploiting mechanical resonances directly, implies a limitation to available signal bandwidth along with the inherent inability to detect DC or very low frequency magnetic fields. The presented work demonstrates converse ME modulation of thin film Si cantilever composites of mesoscopic dimensions (25 mm × 2.45 mm × 0.35 mm), employing piezoelectric AlN and magnetostrictive FeCoSiB films of 2 µm thickness each. A high frequency mechanical resonance at about 515 kHz leads to strong induced voltages in a surrounding pickup coil with matched self-resonance, leading to field sensitivities up to 64 kV/T. A DC limit of detection of 210 pT/Hz1/2 as well as about 70 pT/Hz1/2 at 10 Hz, without the need for a magnetic bias field, pave the way towards biomagnetic applications.
- ItemSlowness curve surface acoustic wave transducers for optimized acoustic streaming(Cambridge : Royal Society of Chemistry, 2020) O'Rorke, R.; Winkler, A.; Collins, D.; Ai, Y.Surface acoustic waves can induce force gradients on the length scales of micro- and nanoparticles, allowing precise manipulation for particle capture, alignment and sorting activities. These waves typically occupy a spatial region much larger than a single particle, resulting in batch manipulation. Circular arc transducers can focus a SAW into a narrow beam on the order of the particle diameter for highly localised, single-particle manipulation by exciting wavelets which propagate to a common focal point. The anisotropic nature of SAW substrates, however, elongates and shifts the focal region. Acousto-microfluidic applications are highly dependent on the morphology of the underlying substrate displacement and, thus, become dependent on the microchannel position relative to the circular arc transducer. This requires either direct measurement or computational modelling of the SAW displacement field. We show that the directly measured elongation and shift in the focal region are recapitulated by an analytical model of beam steering, derived from a simulated slowness curve for 128° Y-cut lithium niobate. We show how the negative effects of beam steering can be negated by adjusting the curvature of arced transducers according to the slowness curve of the substrate, for which we present a simple function for convenient implementation in computational design software. Slowness-curve adjusted transducers do not require direct measurement of the SAW displacement field for microchannel placement and can capture smaller particles within the streaming vortices than can circular arc IDTs.