Nickel sulphide: supplementary statistical data of the heat soak test
Loading...
Date
Authors
Editor
Advisor
Volume
73
Issue
Journal
Glass Science and Technology
Series Titel
Book Title
Publisher
Offenbach : Verlag der Deutschen Glastechnischen Gesellschaft
Supplementary Material
Other Versions
Link to publishers' Version
Abstract
Supplementary heat soak test (HST) breakage data completing those recently published are in good agreement with the latter. The overall evaluation of the whole data set for one type of HST oven with a big number of recorded break events shows that a holding time of 2 h at (290 ± 10) °C is enough to ensure sufficient reliability of the test.