Experience with an SCR DeNOx plant for container glass furnaces
dc.bibliographicCitation.firstPage | 354 | |
dc.bibliographicCitation.journalTitle | Glass Science and Technology | eng |
dc.bibliographicCitation.lastPage | 358 | |
dc.bibliographicCitation.volume | 70 | |
dc.contributor.author | Schmalhorst, Ekhard | |
dc.contributor.author | Ernas, Teomann | |
dc.contributor.author | Jeschke, Ralph | |
dc.date.accessioned | 2024-01-08T07:53:11Z | |
dc.date.available | 2024-01-08T07:53:11Z | |
dc.date.issued | 1997 | |
dc.description.abstract | From 1991 to 1994, P LM Münder installed an integrated flue gas treatment system designed to meet the latest environmental Standards and reduce the overall energy consumption. The system consists of four components: a) A batch preheater was installed on one furnace reducing the energy consumption by 15%. b) A calcium hydroxide absorption tower and electrostatic precipitator unit reduce acid contaminants as well as particulate emissions for all furnaces well below legal limits. c) A selective catalytic reduction (SCR) DeNOx plant reduces nitrogen oxide emissions below the legal limit of 500 mg/m^. d) A waste heat utilization plant generates about 700 kW electricity from the residual heat. The results of the Operation of the SCR DeNOx plant for the years 1995 and 1996 show - there are no operational problems for the DeNOx plant with flue gas of container glass furnaces, - dust problems can be overcome by using dust blowers on a regular basis and additional manual cleaning about once a year, - the deterioration of the catalytic elements is according to the layout calculations, allowing for a life expectancy of about five years and - the overall costs for Installation and operadon of this plant are about D M 3.18/t glass produced. | eng |
dc.description.version | publishedVersion | |
dc.identifier.uri | https://oa.tib.eu/renate/handle/123456789/14242 | |
dc.identifier.uri | https://doi.org/10.34657/13272 | |
dc.language.iso | eng | |
dc.publisher | Offenbach : Verlag der Deutschen Glastechnischen Gesellschaft | |
dc.relation.issn | 0946-7475 | |
dc.rights.license | CC BY 3.0 DE | |
dc.rights.uri | https://creativecommons.org/licenses/by/3.0/de/ | |
dc.subject.ddc | 660 | |
dc.title | Experience with an SCR DeNOx plant for container glass furnaces | eng |
dc.type | Article | eng |
dc.type | Text | eng |
tib.accessRights | openAccess |
Files