Plasmonic Hepatitis B Biosensor for the Analysis of Clinical Saliva

dc.bibliographicCitation.firstPage2972eng
dc.bibliographicCitation.issue5eng
dc.bibliographicCitation.lastPage2977eng
dc.bibliographicCitation.volume89eng
dc.contributor.authorRiedel, Tomáš
dc.contributor.authorHageneder, Simone
dc.contributor.authorSurman, František
dc.contributor.authorPop-Georgievski, Ognen
dc.contributor.authorNoehammer, Christa
dc.contributor.authorHofner, Manuela
dc.contributor.authorBrynda, Eduard
dc.contributor.authorRodriguez-Emmenegger, Cesar
dc.contributor.authorDostálek, Jakub
dc.date.accessioned2022-01-28T07:20:49Z
dc.date.available2022-01-28T07:20:49Z
dc.date.issued2017
dc.description.abstractA biosensor for the detection of hepatitis B antibodies in clinical saliva was developed. Compared to conventional analysis of blood serum, it offers the advantage of noninvasive collection of samples. Detection of biomarkers in saliva imposes two major challenges associated with the low analyte concentration and increased surface fouling. The detection of minute amounts of hepatitis B antibodies was performed by plasmonically amplified fluorescence sandwich immunoassay. To have access to specific detection, we prevented the nonspecific adsorption of biomolecules present in saliva by brushes of poly[(N-(2-hydroxypropyl) methacrylamide)-co-(carboxybetaine methacrylamide)] grafted from the gold sensor surface and post modified with hepatitis B surface antigen. Obtained results were validated against the response measured with ELISA at a certified laboratory using serum from the same patients. © 2017eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/7942
dc.identifier.urihttps://doi.org/10.34657/6983
dc.language.isoengeng
dc.publisherColumbus, Ohio : American Chemical Societyeng
dc.relation.doihttps://doi.org/10.1021/acs.analchem.6b04432
dc.relation.essn1520-6882
dc.relation.ispartofseriesAnalytical Chemistry 89 (2017), Nr. 5eng
dc.rights.licenseCC BY 4.0 Unportedeng
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/eng
dc.subjectAntibodieseng
dc.subjectAntigenseng
dc.subjectBiosensorseng
dc.subjectHepatitis B surface antigeneng
dc.subjectMethacrylamideseng
dc.subjectNonspecific adsorptioneng
dc.subjectSandwich immunoassayeng
dc.subjectSensor surfaceseng
dc.subjectSurface Plasmon Resonanceeng
dc.subjectSpecific detectioneng
dc.subjectBody fluidseng
dc.subjectbiological markereng
dc.subjecthepatitis B antibodyeng
dc.subjectimmobilized proteineng
dc.subjectgenetic procedureseng
dc.subjectimmunologyeng
dc.subjectspectrofluorometryeng
dc.subjectBiomarkerseng
dc.subject.ddc540eng
dc.titlePlasmonic Hepatitis B Biosensor for the Analysis of Clinical Salivaeng
dc.typearticleeng
dc.typeTexteng
dcterms.bibliographicCitation.journalTitleAnalytical chemistryeng
tib.accessRightsopenAccesseng
wgl.contributorDWIeng
wgl.subjectChemieeng
wgl.typeZeitschriftenartikeleng