Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project

dc.bibliographicCitation.firstPageP04015
dc.bibliographicCitation.issue4
dc.bibliographicCitation.journalTitleJournal of Instrumentationeng
dc.bibliographicCitation.volume13
dc.contributor.authorPaolozzi, L.
dc.contributor.authorBandi, Y.
dc.contributor.authorBenoit, M.
dc.contributor.authorCardarelli, R.
dc.contributor.authorDébieux, S.
dc.contributor.authorForshaw, D.
dc.contributor.authorHayakawa, D.
dc.contributor.authorIacobucci, G.
dc.contributor.authorKaynak, M.
dc.contributor.authorMiucci, A.
dc.contributor.authorNessi, M.
dc.contributor.authorRatib, O.
dc.contributor.authorRipiccini, E.
dc.contributor.authorRücker, H.
dc.contributor.authorValerio, P.
dc.contributor.authorWeber, M.
dc.date.accessioned2023-01-24T08:05:52Z
dc.date.available2023-01-24T08:05:52Z
dc.date.issued2018
dc.description.abstractThe TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e− RMS and a pulse rise time of less than 2 ns , in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps .eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/10984
dc.identifier.urihttp://dx.doi.org/10.34657/10010
dc.language.isoeng
dc.publisherLondon : Inst. of Physics
dc.relation.doihttps://doi.org/10.1088/1748-0221/13/04/p04015
dc.relation.essn1748-0221
dc.rights.licenseCC BY 3.0 Unported
dc.rights.urihttps://creativecommons.org/licenses/by/3.0
dc.subject.ddc610
dc.subject.otherFront-end electronics for detector readouteng
dc.subject.otherGamma camera SPECT PET PET/CT coronary CT angiography (CTA)eng
dc.subject.otherSi microstrip and pad detectorseng
dc.subject.otherTiming detectorseng
dc.titleTest beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET projecteng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccess
wgl.contributorIHP
wgl.subjectMedizin, Gesundheitger
wgl.typeZeitschriftenartikelger