Accuracy of linear depolarisation ratios in clean air ranges measured with POLIS-6 at 355 and 532 NM
Loading...
Date
Editor
Advisor
Volume
119
Issue
Journal
EPJ Web of Conferences
Series Titel
Book Title
Publisher
Les Ulis : EDP Sciences
Supplementary Material
Other Versions
Link to publishers' Version
Abstract
Linear depolarization ratios in clean air ranges were measured with POLIS-6 at 355 and 532 nm. The mean deviation from the theoretical values, including the rotational Raman lines within the filter bandwidths, amounts to 0.0005 at 355 nm and to 0.0012 at 532 nm. The mean uncertainty of the measured linear depolarization ratio of clean air is about 0.0005 at 355 nm and about 0.0006 at 532 nm.
Description
Keywords
Keywords GND
Conference
Publication Type
ConferenceObject
Version
publishedVersion
Collections
License
CC BY 4.0 Unported
