A Micro-Cavity Plasma Array Reactor for Fundamental Studies on Plasma-Catalytic Conversion of n-Butane

Loading...
Thumbnail Image

Date

Editor

Advisor

Volume

23

Issue

9

Journal

Plasma Processes and Polymers

Series Titel

Book Title

Publisher

Weinheim : Wiley VCH

Supplementary Material

Other Versions

Link to publishers' Version

Abstract

Using the MCPA, we exemplarily investigate the plasma catalytic conversion of n-butane (C4H10), employing ex-situ Fourier transform infrared spectroscopy at the gas outlet to evaluate conversion efficiency and product selectivity. Systematic examination of gas composition, catalyst material, and temperature reveals that under high helium dilution conditions, varying the specific energy input by voltage from 0.05 to 0.49 eV/molecule yields a maximum conversion of 34%. Surprisingly, the presence of the catalyst at room temperature reduces conversion to a maximum of 20%, demonstrating an anti-synergistic effect under the applied discharge conditions. These findings highlight the need for more efficient plasma catalyst systems to enhance conversion and improve product selectivity.

Description

Keywords GND

Conference

Publication Type

Article

Version

publishedVersion

Collections

License

CC BY 4.0 International