Using Viral Aerosol Fluorescence for Detection of Virus Infectivity Change Induced by Non-thermal Plasma

dc.bibliographicCitation.articleNumber27
dc.bibliographicCitation.issue3
dc.bibliographicCitation.journalTitlePlasma Chemistry and Plasma Processing
dc.bibliographicCitation.volume46
dc.contributor.authorMa, Zhenyu
dc.contributor.authorClack, Herek L.
dc.date.accessioned2026-07-08T07:44:49Z
dc.date.available2026-07-08T07:44:49Z
dc.date.issued2026
dc.description.abstractAirborne transmission of infectious diseases poses a great threat to public health and the global economy, prompting increased interest in the detection and mitigation of infectious airborne pathogens. Development of air disinfection technologies – those that rely on pathogen neutralization or inactivation rather than particle filtration, such as non-thermal plasma (NTP) – can require extensive tests to determine how the degree of disinfection is affected by operational settings, environmental conditions, aerosol composition, pathogen type, among other factors. Such parametric evaluation is made much more tedious by the need to physically extract pre- and post-treatment aerosol samples for comparative microbiological assays in order to measure change in pathogen viability and the efficacy of the neutralization/inactivation process. UV aerosol fluorescence has been used to detect and characterize aerosols of biological origin, such as pollen. In this study, UV fluorescence of MS2 bacteriophage aerosol is studied for its potential to serve as an indicator of changing viral aerosol infectivity, one that can provide a quicker indication of a change in viral aerosol infectivity than conventional bioaerosol collection followed by microbiological assay. In the present study, infectivity assays and fluorescence measurements of viral aerosols are taken before and after non-thermal plasma treatment. Results indicate that NTP treatment induces infectivity loss and diminished fluorescence intensity. Diminished fluorescence intensity and reduced infectivity are positively correlated, both becoming more pronounced with increased intensity of non-thermal plasma treatment. These findings suggest UV aerosol fluorescence could serve as a fast indicator of airborne virus infectivity change during test, evaluation, and optimization of air disinfection processes like NTP.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/40260
dc.identifier.urihttps://doi.org/10.34657/39328
dc.language.isoeng
dc.publisherDordrecht : Springer Science + Business Media B.V.
dc.relation.doihttps://doi.org/10.1007/s11090-026-10648-6
dc.relation.essn1572-8986
dc.relation.issn0272-4324
dc.rights.licenseCC BY 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0
dc.subject.ddc540
dc.subject.otherAerosoleng
dc.subject.otherFluorescenceeng
dc.subject.otherInfectivityeng
dc.subject.otherNon-thermal plasmaeng
dc.subject.otherViruseng
dc.subject.otherLTP researcheng
dc.titleUsing Viral Aerosol Fluorescence for Detection of Virus Infectivity Change Induced by Non-thermal Plasmaeng
dc.typeArticle
tib.accessRightsopenAccess

Files

Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
s11090-026-10648-6-1.pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
s11090-026-10648-6-1-jats.xml
Size:
74.89 KB
Format:
Extensible Markup Language
Description:

Collections