Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project

dc.bibliographicCitation.firstPageP02009eng
dc.bibliographicCitation.issue2eng
dc.bibliographicCitation.journalTitleJournal of Instrumentationeng
dc.bibliographicCitation.volume14eng
dc.contributor.authorPaolozzi, L.
dc.contributor.authorBandi, Y.
dc.contributor.authorCardarelli, R.
dc.contributor.authorDébieux, S.
dc.contributor.authorFavre, Y.
dc.contributor.authorFerrère, D.
dc.contributor.authorForshaw, D.
dc.contributor.authorHayakawa, D.
dc.contributor.authorIacobucci, G.
dc.contributor.authorKaynak, M.
dc.contributor.authorMiucci, A.
dc.contributor.authorNessi, M.
dc.contributor.authorRipiccini, E.
dc.contributor.authorRücker, H.
dc.contributor.authorValerio, P.
dc.contributor.authorWeber, M.
dc.date.accessioned2021-11-16T10:54:52Z
dc.date.available2021-11-16T10:54:52Z
dc.date.issued2019
dc.description.abstractThe TT-PET collaboration is developing a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 03 × 1 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 µm and backside metallized, was operated at a voltage of 180 V. The tests on a beam line of minimum ionizing particles show a detection efficiency greater than 99.9% and a time resolution down to 110 ps. © 2019 CERN.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/7305
dc.identifier.urihttps://doi.org/10.34657/6352
dc.language.isoengeng
dc.publisherLondon : Inst. of Physicseng
dc.relation.doihttps://doi.org/10.1088/1748-0221/14/02/P02009
dc.relation.essn1748-0221
dc.rights.licenseCC BY 3.0 Unportedeng
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/eng
dc.subject.ddc610eng
dc.subject.otherGamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA)eng
dc.subject.otherPixelated detectors and associated VLSI electronicseng
dc.subject.otherSolid state detectorseng
dc.subject.otherTiming detectorseng
dc.titleCharacterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET projecteng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorIHPeng
wgl.subjectMedizin, Gesundheiteng
wgl.typeZeitschriftenartikeleng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project.pdf
Size:
3.79 MB
Format:
Adobe Portable Document Format
Description:
Collections