Browsing by Author "Finke, Birgit"
Now showing 1 - 8 of 8
Results Per Page
Sort Options
- ItemAnalyse und Modellierung der Einwirkung gepulster Plasmen mit Oberflächen, Teilvorhaben: Grundlegende Gasphasen- und Oberflächenprozesse bei der Wechselwirkung gepulster stickstoffhaltiger Plasmen mit Oberflächen : Schlussbericht(Hannover : Technische Informationsbibliothek (TIB), 2004) Ohl, Andreas; Finke, Birgit; Schröder, Karsten[no abstract available]
- ItemEnhanced calcium ion mobilization in osteoblasts on amino group containing plasma polymer nanolayer(London : BioMed Central, 2018-3-21) Staehlke, Susanne; Rebl, Henrike; Finke, Birgit; Mueller, Petra; Gruening, Martina; Nebe, J. BarbaraBackground: Biomaterial modifications—chemical and topographical—are of particular importance for the integration of materials in biosystems. Cells are known to sense these biomaterial characteristics, but it has remained unclear which physiological processes bio modifications trigger. Hence, the question arises of whether the dynamic of intracellular calcium ions is important for the characterization of the cell–material interaction. In our prior research we could demonstrate that a defined geometrical surface topography affects the cell physiology; this was finally detectable in a reduced intracellular calcium mobilization after the addition of adenosine triphosphate (ATP). Results: This new contribution examines the cell physiology of human osteoblasts concerning the relative cell viability and the calcium ion dynamic on different chemical modifications of silicon–titanium (Ti) substrates. Chemical modifications comprising the coating of Ti surfaces with a plasma polymerized allylamine (PPAAm)-layer or with a thin layer of collagen type-I were compared with a bare Ti substrate as well as tissue culture plastic. For this purpose, the human osteoblasts (MG-63 and primary osteoblasts) were seeded onto the surfaces for 24 h. The relative cell viability was determined by colorimetric measurements of the cell metabolism and relativized to the density of cells quantified using crystal violet staining. The calcium ion dynamic of osteoblasts was evaluated by the calcium imaging analysis of fluo-3 stained vital cells using a confocal laser scanning microscope. The positively charged nano PPAAm-layer resulted in enhanced intracellular calcium ion mobilization after ATP-stimulus and cell viability. This study underlines the importance of the calcium signaling for the manifestation of the cell physiology. Conclusions: Our current work provides new insights into the intracellular calcium dynamic caused by diverse chemical surface compositions. The calcium ion dynamic appears to be a sensitive parameter for the cell physiology and, thus, may represent a useful approach for evaluating a new biomaterial. In this regard, reliable in vitro-tests of cell behavior at the interface to a material are crucial steps in securing the success of a new biomaterial in medicine.
- ItemGas-discharge plasma-assisted functionalization of titanium implant surfaces(Baech : Trans Tech Publications Ltd., 2010) Schröder, Karsten; Finke, Birgit; Polak, Martin; Lüthen, Frank; Nebe, Barbara; Rychly, Joachim; Bader, Rainer; Lukowski, Gerold; Walschus, Uwe; Schlosser, Michael; Ohl, Andreas; Weltmann, Klaus DieterA crucial factor for in-growth of metallic implants in the bone stock is the rapid cellular acceptance whilst prevention of bacterial adhesion on the surface. Such contradictorily adhesion events could be triggered by surface properties. There already exists fundamental knowledge about the influence of physicochemical surface properties like roughness, titanium dioxide modifications, cleanness, and (mainly ceramic) coatings on cell and microbial behavior in vitro and in vivo. The titanium surface can be equipped with antimicrobial properties by plasma-based copper implantation, which allows the release and generation of small concentrations of copper ions during contact with water-based biological liquids. Additionally, the titanium surface was equipped with amino groups by the deposition of an ultrathin plasma polymer. This coating on the one hand does not significantly reduce the generation of copper ions, and on the other hand improves the adhesion and spreading of osteoblast cells. The process development was accompanied by physicochemical surface analyses like XPS, FTIR, contact angle, SEM, and AFM. Very thin modified layers were created, which are resistant to hydrolysis and delamination. These titanium surface functionalizations were found to have either an antimicrobial activity or cell-adhesive properties. Intramuscular implantation of titanium samples coated with the cell-adhesive plasma polymer in rats revealed a reduced inflammation reaction compared to uncoated titanium. © (2010) Trans Tech Publications.
- ItemLocal Inflammatory Response after Intramuscularly Implantation of Anti-Adhesive Plasma-Fluorocarbon-Polymer Coated Ti6AI4V Discs in Rats(Basel : MDPI, 2021) Koppe, Charlotte; Hoene, Andreas; Walschus, Uwe; Finke, Birgit; Testrich, Holger; Pohl, Christopher; Brandt, Nico; Patrzyk, Maciej; Meichsner, Jürgen; Nebe, Barbara; Schlosser, MichaelOrthopaedic implants and temporary osteosynthesis devices are commonly based on Titanium (Ti). For short-term devices, cell-material contact should be restricted for easy removal after bone healing. This could be achieved with anti-adhesive plasma-fluorocarbon-polymer (PFP) films created by low-temperature plasma processes. Two different PFP thin film deposition techniques, microwave (MW) and radiofrequency (RF) discharge plasma, were applied to receive smooth, hydrophobic surfaces with octafluoropropane (C3F8) or hexafluorohexane (C6F6) as precursors. This study aimed at examining the immunological local tissue reactions after simultaneous intramuscular implantation of four different Ti samples, designated as MW-C3F8, MW-C6F6, RF-C3F8 and Ti-controls, in rats. A differentiated morphometric evaluation of the inflammatory reaction was conducted by immunohistochemical staining of CD68+ macrophages, CD163+ macrophages, MHC class II-positive cells, T lymphocytes, CD25+ regulatory T lymphocytes, NK cells and nestin-positive cells in cryosections of surrounding peri-implant tissue. Tissue samples were obtained on days 7, 14 and 56 for investigating the acute and chronical inflammation (n = 8 rats/group). Implants with a radiofrequency discharge plasma (RF-C3F8) coating exhibited a favorable short- and long-term immune/inflammatory response comparable to Ti-controls. This was also demonstrated by the significant decrease in pro-inflammatory CD68+ macrophages, possibly downregulated by significantly increasing regulatory T lymphocytes.
- ItemPlasma polymerized allylamine-the unique cell-attractive nanolayer for dental implant materials(Basel : MDPI, 2019) Nebe, J. Barbara; Rebl, Henrike; Schlosser, Michael; Staehlke, Susanne; Gruening, Martina; Weltmann, Klaus-Dieter; Walschus, Uwe; Finke, BirgitBiomaterials should be bioactive in stimulating the surrounding tissue to accelerate the ingrowth of permanent implants. Chemical and topographical features of the biomaterial surface affect cell physiology at the interface. A frequently asked question is whether the chemistry or the topography dominates the cell-material interaction. Recently, we demonstrated that a plasma-chemical modification using allylamine as a precursor was able to boost not only cell attachment and cell migration, but also intracellular signaling in vital cells. This microwave plasma process generated a homogenous nanolayer with randomly distributed, positively charged amino groups. In contrast, the surface of the human osteoblast is negatively charged at −15 mV due to its hyaluronan coat. As a consequence, we assumed that positive charges at the material surface—provoking electrostatic interaction forces—are attractive for the first cell encounter. This plasma-chemical nanocoating can be used for several biomaterials in orthopedic and dental implantology like titanium, titanium alloys, calcium phosphate scaffolds, and polylactide fiber meshes produced by electrospinning. In this regard, we wanted to ascertain whether plasma polymerized allylamine (PPAAm) is also suitable for increasing the attractiveness of a ceramic surface for dental implants using Yttria-stabilized tetragonal zirconia.
- ItemPoly (hexamethylene biguanide), adsorbed onto Ti-Al-V alloys, kills slime-producing Staphylococci and Pseudomonas aeruginosa without inhibiting SaOs-2 cell differentiation(Hoboken, NJ : Wiley, 2020) Hornschuh, Melanie; Zwicker, Paula; Schmidt, Thomas; Finke, Birgit; Kramer, Axel; Müller, GeraldAntimicrobial coating of implant material with poly(hexamethylene biguanide) hydrochloride (PHMB) may be an eligible method for preventing implant-associated infections. In the present study, an antibacterial effective amount of PHMB is adsorbed on the surface of titanium alloy after simple chemical pretreatment. Either oxidation with 5% H2O2 for 24 hr or processing for 2 hr in 5 M NaOH provides the base for the subsequent formation of a relatively stable self-assembled PHMB layer. Compared with an untreated control group, adsorbed PHMB produces no adverse effects on SaOs-2 cells within 48 hr cell culture, but promotes the initial attachment and spreading of the osteoblasts within 15 min. Specimens were inoculated with slime-producing bacteria to simulate a perioperative infection. Adsorbed PHMB reacts bactericidally against Staphylococcus aureus, Staphylococcus epidermidis, and Pseudomonas aeruginosa after surface contact. Adhered SaOs-2 cells differentiate and produce alkaline phosphatase and deposit calcium within 4 days in a mineralization medium on PHMB-coated Ti6Al4V surfaces, which have been precontaminated with S. epidermidis. The presented procedures provide a simple method for generating biocompatibly and antimicrobially effective implant surfaces that may be clinically important. © 2019 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials published by Wiley Periodicals, Inc.
- ItemQuantification of osseointegration of plasma-polymer coated titanium alloyed implants by means of microcomputed tomography versus histomorphometry(New York [u.a.] : Hindawi, 2015) Gabler, Carolin; Zietz, Carmen; Bieck, Richard; Göhler, Rebecca; Lindner, Tobias; Haenle, Maximilian; Finke, Birgit; Meichsner, Jürgen; Testrich, Holger; Nowottnick, Mathias; Frerich, Bernhard; Bader, RainerA common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined by µCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% and µCT: 51.8% and 62.0%, resp.). Mean BIC calculated by µCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 () was found between 3D and 2D quantification of BIC. The μCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface.
- ItemRestricted cell functions on micropillars are alleviated by surface-nanocoating with amino groups(Cambridge : Company of Biologists Limited, 2018) Moerke, Caroline; Staehlke, Susanne; Rebl, Henrike; Finke, Birgit; Nebe, J. BarbaraThe topographical and chemical surface features of biomaterials are sensed by the cells, affecting their physiology at the interface. When placed on titanium, we recently discovered osteoblasts attempted caveolae-mediated phagocytosis of the sharp-edged microstructures. This active, energy-consuming process resulted in decreased osteoblastic cell functions (e.g. secretion of extracellular matrix proteins). However, chemical modification with plasma polymerized allylamine (PPAAm) was able to amplify osteoblast adhesion and spreading, resulting in better implant osseointegration in vivo. In the present in vitro study, we analyzed whether this plasma polymer nanocoating is able to attenuate the microtopography-induced changes of osteoblast physiology. On PPAAm, we found cells showed a higher cell interaction with the geometrical micropillars by 30 min, and a less distinct reduction in the mRNA expression of collagen type I, osteocalcin and fibronectin after 24 h of cell growth. Interestingly, the cells were more active and sensitive on PPAAm-coated micropillars, and react with a substantial Ca2+ ion mobilization after stimulation with ATP. These results highlight that it is important for osteoblasts to establish cell surface contact for them to perform their functions.