From In Vitro to Perioperative Vascular Tissue Engineering: Shortening Production Time by Traceable Textile-Reinforcement

dc.bibliographicCitation.firstPage1169
dc.bibliographicCitation.issue6
dc.bibliographicCitation.journalTitleTissue Engineering and Regenerative Medicineeng
dc.bibliographicCitation.lastPage1184
dc.bibliographicCitation.volume19
dc.contributor.authorMohapatra, Saurav Ranjan
dc.contributor.authorRama, Elena
dc.contributor.authorMelcher, Christoph
dc.contributor.authorCall, Tobias
dc.contributor.authorAl Enezy-Ulbrich, Miriam Aischa
dc.contributor.authorPich, Andrij
dc.contributor.authorApel, Christian
dc.contributor.authorKiessling, Fabian
dc.contributor.authorJockenhoevel, Stefan
dc.date.accessioned2023-02-06T10:22:45Z
dc.date.available2023-02-06T10:22:45Z
dc.date.issued2022
dc.description.abstractBackground: The production of tissue-engineered vascular graft (TEVG) usually involves a prolonged bioreactor cultivation period of up to several weeks to achieve maturation of extracellular matrix and sufficient mechanical strength. Therefore, we aimed to substantially shorten this conditioning time by combining a TEVG textile scaffold with a recently developed copolymer reinforced fibrin gel as a cell carrier. We further implemented our grafts with magnetic resonance imaging (MRI) contrast agents to allow the in-vitro monitoring of the TEVG’s remodeling process. Methods: Biodegradable polylactic-co-glycolic acid (PLGA) was electrospun onto a non-degradable polyvinylidene fluoride scaffold and molded along with copolymer-reinforced fibrin hydrogel and human arterial cells. Mechanical tests on the TEVGs were performed both instantly after molding and 4 days of bioreactor conditioning. The non-invasive in vitro monitoring of the PLGA degradation and the novel imaging of fluorinated thermoplastic polyurethane (19F-TPU) were performed using 7T MRI. Results: After 4 days of close loop bioreactor conditioning, 617 ± 85 mmHg of burst pressure was achieved, and advanced maturation of extracellular matrix (ECM) was observed by immunohistology, especially in regards to collagen and smooth muscle actin. The suture retention strength (2.24 ± 0.3 N) and axial tensile strength (2.45 ± 0.58 MPa) of the TEVGs achieved higher values than the native arteries used as control. The contrast agents labeling of the TEVGs allowed the monitorability of the PLGA degradation and enabled the visibility of the non-degradable textile component. Conclusion: Here, we present a concept for a novel textile-reinforced TEVG, which is successfully produced in 4 days of bioreactor conditioning, characterized by increased ECM maturation and sufficient mechanical strength. Additionally, the combination of our approach with non-invasive imaging provides further insights into TEVG’s clinical application.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/11283
dc.identifier.urihttp://dx.doi.org/10.34657/10319
dc.language.isoeng
dc.publisherHeidelberg : Springer
dc.relation.doihttps://doi.org/10.1007/s13770-022-00482-0
dc.relation.essn2212-5469
dc.relation.issn1738-2696
dc.rights.licenseCC BY 4.0 Unported
dc.rights.urihttps://creativecommons.org/licenses/by/4.0
dc.subject.ddc570
dc.subject.otherElectrospun scaffoldseng
dc.subject.otherNon-invasive monitoringeng
dc.subject.otherTissue-engineered vascular graftseng
dc.titleFrom In Vitro to Perioperative Vascular Tissue Engineering: Shortening Production Time by Traceable Textile-Reinforcementeng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccess
wgl.contributorDWI
wgl.subjectBiowissenschaften/Biologieger
wgl.typeZeitschriftenartikelger
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
s13770-022-00482-0.pdf
Size:
2.27 MB
Format:
Adobe Portable Document Format
Description: