Development of a control system for the teat-end vacuum in individual quarter milking systems

dc.bibliographicCitation.firstPage7633eng
dc.bibliographicCitation.issue6eng
dc.bibliographicCitation.journalTitleSensorseng
dc.bibliographicCitation.lastPage7651eng
dc.bibliographicCitation.volume13
dc.contributor.authorStröbel, Ulrich
dc.contributor.authorRose-Meierhöfer, Sandra
dc.contributor.authorÖz, Hülya
dc.contributor.authorBrunsch, Reiner
dc.date.accessioned2017-08-02T00:25:09Z
dc.date.available2019-06-28T13:38:27Z
dc.date.issued2013
dc.description.abstractProgress in sensor technique and electronics has led to a decrease in the costs of electronic and sensor components. In modern dairy farms, having udders in good condition, a lower frequency of udder disease and an extended service life of dairy cows will help ensure competitiveness. The objective of this study was to develop a teat-end vacuum control system with individual quarter actor reaction. Based on a review of the literature, this system is assumed to protect the teat tissue. It reduces the mean teat-end vacuum in the maximum vacuum phase (b) to a level of 20 kPa at a flow rate of 0.25 L/min per quarter. At flow rates higher than 1.50 L/min per quarter, the teat-end vacuum can be controlled to a level of 30 kPa, because in this case it is desirable to have a higher vacuum for the transportation of the milk to the receiver. With this system it is possible for the first time to supply the teat end with low vacuum at low flow rates and with higher vacuum at increasing flow rates in a continuous process with a three second reaction-rate on individual quarter level. This system is completely automated.eng
dc.description.versionpublishedVersioneng
dc.formatapplication/pdf
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/4586
dc.identifier.urihttps://doi.org/10.34657/225
dc.language.isoengeng
dc.publisherBasel : MDPIeng
dc.relation.doihttps://doi.org/10.3390/s130607633
dc.rights.licenseCC BY-NC-SA 3.0 Unportedeng
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/eng
dc.subject.ddc630eng
dc.subject.othervacuum control valveeng
dc.subject.otherpressure sensoreng
dc.subject.othervacuum control systemeng
dc.subject.otherfluctuationeng
dc.subject.otherreductioneng
dc.subject.othermilk flow rateeng
dc.subject.otherteat-endeng
dc.titleDevelopment of a control system for the teat-end vacuum in individual quarter milking systemseng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorATBeng
wgl.subjectLandwirtschafteng
wgl.typeZeitschriftenartikeleng