Search Results

Now showing 1 - 4 of 4
  • Item
    Wet-Spun PEDOT/CNT Composite Hollow Fibers as Flexible Electrodes for H2O2 Production
    (Weinheim : Wiley-VCH, 2021) Cui, Qing; Bell, Daniel Josef; Wang, Siqi; Mohseni, Mojtaba; Felder, Daniel; Lölsberg, Jonas; Wessling, Matthias
    The electrochemical synthesis of hydrogen peroxide (H2O2) using the oxygen reduction reaction (ORR) requires highly catalytic active, selective, and stable electrode materials to realize a green and efficient process. The present publication shows for the first time the application of a facile one-step bottom-up wet-spinning approach for the continuous fabrication of stable and flexible tubular poly(3,4-ethylene dioxythiophene) (PEDOT : PSS) and PEDOT : PSS/carbon nanotube (CNT) hollow fibers. Additionally, electrochemical experiments reveal the catalytic activity of acid-treated PEDOT : PSS and its composites in the ORR forming hydrogen peroxide for the first time. Under optimized conditions, the composite electrodes with 40 wt % CNT loading could achieve a high production rate of 0.01 mg/min/cm2 and a current efficiency of up to 54 %. In addition to the high production rate, the composite hollow fiber has proven its long-term stability with 95 % current retention after 20 h of hydrogen peroxide production. © 2021 The Authors. ChemElectroChem published by Wiley-VCH GmbH
  • Item
    High-Throughput Production of Micrometer Sized Double Emulsions and Microgel Capsules in Parallelized 3D Printed Microfluidic Devices
    (Basel : MDPI, 2019) Jans, Alexander; Lölsberg, Jonas; Omidinia-Anarkoli, Abdolrahman; Viermann, Robin; Möller, Martin; De Laporte, Laura; Wessling, Matthias; Kuehne, Alexander J. C.
    Double emulsions are useful geometries as templates for core-shell particles, hollow sphere capsules, and for the production of biomedical delivery vehicles. In microfluidics, two approaches are currently being pursued for the preparation of microfluidic double emulsion devices. The first approach utilizes soft lithography, where many identical double-flow-focusing channel geometries are produced in a hydrophobic silicone matrix. This technique requires selective surface modification of the respective channel sections to facilitate alternating wetting conditions of the channel walls to obtain monodisperse double emulsion droplets. The second technique relies on tapered glass capillaries, which are coaxially aligned, so that double emulsions are produced after flow focusing of two co-flowing streams. This technique does not require surface modification of the capillaries, as only the continuous phase is in contact with the emulsifying orifice; however, these devices cannot be fabricated in a reproducible manner, which results in polydisperse double emulsion droplets, if these capillary devices were to be parallelized. Here, we present 3D printing as a means to generate four identical and parallelized capillary device architectures, which produce monodisperse double emulsions with droplet diameters in the range of 500 µm. We demonstrate high throughput synthesis of W/O/W and O/W/O double emulsions, without the need for time-consuming surface treatment of the 3D printed microfluidic device architecture. Finally, we show that we can apply this device platform to generate hollow sphere microgels.
  • Item
    Microfluidic cell sorting: Towards improved biocompatibility of extracorporeal lung assist devices
    ([London] : Macmillan Publishers Limited, part of Springer Nature, 2018) Bleilevens, Christian; Lölsberg, Jonas; Cinar, Arne; Knoben, Maren; Grottke, Oliver; Rossaint, Rolf; Wessling, Matthias
    Extracorporeal lung assist technology is one of the last options in critical care medicine to treat patients suffering from severe oxygenation and decarboxylation disorders. Platelet activation along with the consequent thrombus formation is a potentially life-threatening complication of this technique. To avoid platelet-dependent clot formation, this study aims at developing a microfluidic cell sorting chip that can bypass platelets prior to the membrane oxygenator of the extracorporeal lung assist device. The cell sorting chips were produced by maskless dip-in laser lithography, followed by soft lithography replication using PDMS. Citrated porcine whole blood with a clinically relevant haematocrit of 17% was used for the cell sorting experiments involving three different blood flow rates. The joint effects of flow focusing and hydrodynamic lifting forces within the cell sorting chip resulted in a reduction of up to 57% of the baseline platelet count. This cell sorting strategy is suitable for the continuous and label-free separation of red blood cells and platelets and is potentially applicable for increasing the biocompatibility and lifetime of current extracorporeal lung assist devices.
  • Item
    Templating the morphology of soft microgel assemblies using a nanolithographic 3D-printed membrane
    ([London] : Macmillan Publishers Limited, part of Springer Nature, 2021) Linkhorst, John; Lölsberg, Jonas; Thill, Sebastian; Lohaus, Johannes; Lüken, Arne; Naegele, Gerhard; Wessling, Matthias
    Filter cake formation is the predominant phenomenon limiting the filtration performance of membrane separation processes. However, the filter cake’s behavior at the particle scale, which determines its overall cake behavior, has only recently come into the focus of scientists, leaving open questions about its formation and filtration behavior. The present study contributes to the fundamental understanding of soft filter cakes by analyzing the influence of the porous membrane’s morphology on crystal formation and the compaction behavior of soft filter cakes under filtration conditions. Microfluidic chips with nanolithographic imprinted filter templates were used to trigger the formation of crystalline colloidal filter cakes formed by soft microgels. The soft filter cakes were observed via confocal laser scanning microscopy (CLSM) under dead-end filtration conditions. Colloidal crystal formation in the cake, as well as their compaction behavior, were analyzed by optical visualization and pressure data. For the first time, we show that exposing the soft cake to a crystalline filter template promotes the formation of colloidal crystallites and that soft cakes experience gradient compression during filtration.