Search Results

Now showing 1 - 3 of 3
  • Item
    The chemistry of OH and HO2 radicals in the boundary layer over the tropical Atlantic Ocean
    (München : European Geopyhsical Union, 2010) Whalley, L.K.; Furneaux, K.L.; Goddard, A.; Lee, J.D.; Mahajan, A.; Oetjen, H.; Read, K.A.; Kaaden, N.; Carpenter, L.J.; Lewis, A.C.; Plane, J.M.C.; Saltzman, E.S.; Wiedensohler, A.; Heard, D.E.
    Fluorescence Assay by Gas Expansion (FAGE) has been used to detect ambient levels of OH and HO2 radicals at the Cape Verde Atmospheric Observatory, located in the tropical Atlantic marine boundary layer, during May and June 2007. Midday radical concentrations were high, with maximum concentrations of 9 ×106 molecule cm−3 and 6×108 molecule cm−3 observed for OH and HO2, respectively. A box model incorporating the detailed Master Chemical Mechanism, extended to include halogen chemistry, heterogeneous loss processes and constrained by all available measurements including halogen and nitrogen oxides, has been used to assess the chemical and physical parameters controlling the radical chemistry. The model was able to reproduce the daytime radical concentrations to within the 1 σ measurement uncertainty of 20% during the latter half of the measurement period but significantly under-predicted [HO2] by 39% during the first half of the project. Sensitivity analyses demonstrate that elevated [HCHO] (~2 ppbv) on specific days during the early part of the project, which were much greater than the mean [HCHO] (328 pptv) used to constrain the model, could account for a large portion of the discrepancy between modelled and measured [HO2] at this time. IO and BrO, although present only at a few pptv, constituted ~19% of the instantaneous sinks for HO2, whilst aerosol uptake and surface deposition to the ocean accounted for a further 23% of the HO2 loss at noon. Photolysis of HOI and HOBr accounted for ~13% of the instantaneous OH formation. Taking into account that halogen oxides increase the oxidation of NOx (NO → NO2), and in turn reduce the rate of formation of OH from the reaction of HO2 with NO, OH concentrations were estimated to be 9% higher overall due to the presence of halogens. The increase in modelled OH from halogen chemistry gives an estimated 9% shorter lifetime for methane in this region, and the inclusion of halogen chemistry is necessary to model the observed daily cycle of O3 destruction that is observed at the surface. Due to surface losses, we hypothesise that HO2 concentrations increase with height and therefore contribute a larger fraction of the O3 destruction than at the surface.
  • Item
    Mobility particle size spectrometers: Harmonization of technical standards and data structure to facilitate high quality long-term observations of atmospheric particle number size distributions
    (München : European Geopyhsical Union, 2012) Wiedensohler, A.; Birmili, W.; Nowak, A.; Sonntag, A.; Weinhold, K.; Merkel, M.; Wehner, B.; Tuch, T.; Pfeifer, S.; Fiebig, M.; Fjäraa, A.M.; Asmi, E.; Sellegri, K.; Depuy, R.; Venzac, H.; Villani, P.; Laj, P.; Aalto, P.; Ogren, J.A.; Swietlick, E.; Williams, P.; Roldin, P.; Quincey, P.; Hüglin, C.; Fierz-Schmidhauser, R.; Gysel, M.; Weingartner, E.; Riccobono, F.; Santos, S.; Grüning, C.; Faloon, K.; Beddows, D.; Harrison, R.; Monahan, C.; Jennings, S.G.; O'Dowd, C.D.; Marinoni, A.; Horn, H.-G.; Keck, L.; Jiang, J.; Scheckman, J.; McMurry, P.H.; Deng, Z.; Zhao, C.S.; Moerman, M.; Henzing, B.; de Leeuw, G.; Löschau, G.; Bastian, S.
    Mobility particle size spectrometers often referred to as DMPS (Differential Mobility Particle Sizers) or SMPS (Scanning Mobility Particle Sizers) have found a wide range of applications in atmospheric aerosol research. However, comparability of measurements conducted world-wide is hampered by lack of generally accepted technical standards and guidelines with respect to the instrumental set-up, measurement mode, data evaluation as well as quality control. Technical standards were developed for a minimum requirement of mobility size spectrometry to perform long-term atmospheric aerosol measurements. Technical recommendations include continuous monitoring of flow rates, temperature, pressure, and relative humidity for the sheath and sample air in the differential mobility analyzer. We compared commercial and custom-made inversion routines to calculate the particle number size distributions from the measured electrical mobility distribution. All inversion routines are comparable within few per cent uncertainty for a given set of raw data. Furthermore, this work summarizes the results from several instrument intercomparison workshops conducted within the European infrastructure project EUSAAR (European Supersites for Atmospheric Aerosol Research) and ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) to determine present uncertainties especially of custom-built mobility particle size spectrometers. Under controlled laboratory conditions, the particle number size distributions from 20 to 200 nm determined by mobility particle size spectrometers of different design are within an uncertainty range of around ±10% after correcting internal particle losses, while below and above this size range the discrepancies increased. For particles larger than 200 nm, the uncertainty range increased to 30%, which could not be explained. The network reference mobility spectrometers with identical design agreed within ±4% in the peak particle number concentration when all settings were done carefully. The consistency of these reference instruments to the total particle number concentration was demonstrated to be less than 5%. Additionally, a new data structure for particle number size distributions was introduced to store and disseminate the data at EMEP (European Monitoring and Evaluation Program). This structure contains three levels: raw data, processed data, and final particle size distributions. Importantly, we recommend reporting raw measurements including all relevant instrument parameters as well as a complete documentation on all data transformation and correction steps. These technical and data structure standards aim to enhance the quality of long-term size distribution measurements, their comparability between different networks and sites, and their transparency and traceability back to raw data.
  • Item
    Submicrometer aerosol particle distributions in the upper troposphere over the mid-latitude North Atlantic - Results from the third route of 'CARIBIC'
    (Milton Park : Taylor & Francis, 2017) Hermann, M.; Brenninkmeijer, C.A.M.; Slemr, F.; Heintzenberg, J.; Martinsson, B.G.; Schlager, H.; Van Velthoven, P.F.J.; Wiedensohler, A.; Zahn, A.; Ziereis, H.
    Particle number and mass concentrations of submicrometer aerosol particles were determined for the upper troposphere over the mid-latitude North Atlantic within the Civil Aircraft for Regular Investigation of the Atmosphere Based on an Instrument Container project (CARIBIC, http://www.caribic-atmospheric.com). Between May 2001 and April 2002, 22 flights from Germany to the Caribbean were conducted using an automated measurement container on a B767 passenger aircraft. Spatial and seasonal probability distributions for ultrafine and Aitken mode particles as well as mass concentrations of particulate sulphur in 8–12 km altitude are presented. High particle number concentrations (mostly 2500–15 000 particles cm-3 STP) are particularly found in summer over the western North Atlantic Ocean close to the North American continent. The distributions together with an analysis of particle source processes show that deep vertical transport is the dominant process leading to most of the events with high particle number concentrations (8000 particles cm-3 STP) for ultrafine particles as well as for Aitken mode particles. This study emphasizes the importance of deep vertical transport and cloud processing for the concentration of aerosol particles in the upper troposphere.