Search Results

Now showing 1 - 4 of 4
  • Item
    Attosecond investigation of extreme-ultraviolet multi-photon multi-electron ionization
    (Washington, DC : OSA, 2022) Kretschmar, M.; Hadjipittas, A.; Major, B.; Tümmler, J.; Will, I.; Nagy, T.; Vrakking, M. J. J.; Emmanouilidou, A.; Schütte, B.
    Multi-electron dynamics in atoms and molecules very often occur on sub- to few-femtosecond time scales. The available intensities of extreme-ultraviolet (XUV) attosecond pulses have previously allowed the time-resolved investigation of two-photon, two-electron interactions. Here we study double and triple ionization of argon atoms involving the absorption of up to five XUV photons using a pair of intense attosecond pulse trains (APTs). By varying the time delay between the two APTs with attosecond precision and the spatial overlap with nanometer precision, we obtain information on complex nonlinear multi-photon ionization pathways. Our experimental and numerical results show that Ar2+ is predominantly formed by a sequential two-photon process, whereas the delay dependence of the Ar3+ ion yield exhibits clear signatures of the involvement of a simultaneous two-photon absorption process. Our experiment suggests that it is possible to investigate multi-electron dynamics using attosecond pulses for both pumping and probing the dynamics.
  • Item
    Compact intense extreme-ultraviolet source
    (Washington, DC : OSA, 2021) Major, Balázs; Ghafur, Omair; Kovács, Katalin; Varjú, Katalin; Tosa, Valer; Vrakking, Marc J. J.; Schütte, B.
    High-intensity laser pulses covering the ultraviolet to terahertz spectral regions are nowadays routinely generated in a large number of laboratories. In contrast, intense extreme-ultraviolet (XUV) pulses have only been demonstrated using a small number of sources including free-electron laser facilities [1-3] and long high-harmonic generation (HHG) beamlines [4-9]. Here we demonstrate a concept for a compact intense XUV source based on HHG that is focused to an intensity of $2 \times 10^{14}$ W/cm$^2$, with a potential increase up to $10^{17}$ W/cm$^2$ in the future. Our approach uses tight focusing of the near-infrared (NIR) driving laser and minimizes the XUV virtual source size by generating harmonics several Rayleigh lengths away from the NIR focus. Accordingly, the XUV pulses can be refocused to a small beam waist radius of 600 nm, enabling the absorption of up to four XUV photons by a single Ar atom in a setup that fits on a modest (2 m) laser table. Our concept represents a straightforward approach for the generation of intense XUV pulses in many laboratories, providing novel opportunities for XUV strong-field and nonlinear optics experiments, for XUV-pump XUV-probe spectroscopy and for the coherent diffractive imaging of nanoscale structures.
  • Item
    Linear chirped slope profile for spatial calibration in slope measuring deflectometry
    (Melville, NY : American Institute of Physics, 2016) Siewert, F.; Zeschke, T.; Arnold, T.; Paetzelt, H; Yashchuk, V.V.
    Slope measuring deflectometry is commonly used by the X-ray optics community to measure the long-spatial-wavelength surface figure error of optical components dedicated to guide and focus X-rays under grazing incidence condition at synchrotron and free electron laser beamlines. The best performing instruments of this kind are capable of absolute accuracy on the level of 30-50 nrad. However, the exact bandwidth of the measurements, determined at the higher spatial frequencies by the instrument’s spatial resolution, or more generally by the instrument’s modulation transfer function (MTF) is hard to determine. An MTF calibration method based on application of a test surface with a one-dimensional (1D) chirped height profile of constant amplitude was suggested in the past. In this work, we propose a new approach to designing the test surfaces with a 2D-chirped topography, specially optimized for MTF characterization of slope measuring instruments. The design of the developed MTF test samples based on the proposed linear chirped slope profiles (LCSPs) is free of the major drawback of the 1D chirped height profiles, where in the slope domain, the amplitude strongly increases with the local spatial frequency of the profile. We provide the details of fabrication of the LCSP samples. The results of first application of the developed test samples to measure the spatial resolution of the BESSY-NOM at different experimental arrangements are also presented and discussed.
  • Item
    Photon-electron coincidence experiments at synchrotron radiation facilities with arbitrary bunch modes
    ([S.l.] : American Institute of Physics, 2021) Ozga, C.; Honisch, C.; Schmidt, P.; Holzapfel, X.; Zindel, C.; Küstner-Wetekam, C.; Richter, C.; Hergenhahn, U.; Ehresmann, A.; Knie, A.; Hans, A.
    We report the adaptation of an electron–photon coincidence detection scheme to the multibunch hybrid mode of the synchrotron radiation source BESSY II (Helmholtz-Zentrum Berlin). Single-event-based data acquisition and evaluation, combined with the use of relative detection times between the coincident particles, enable the acquisition of proper coincidence signals from a quasi-continuous excitation pattern. The background signal produced by accidental coincidences in the time difference representation is modeled using the non-coincident electron and photon spectra. We validate the method by reproducing previously published results, which were obtained in the single bunch mode, and illustrate its usability for the multibunch hybrid mode by investigating the photoionization of CO2 into CO+2 B satellite states, followed by subsequent photon emission. The radiative lifetime obtained and the electron binding energy are in good agreement with earlier publications. We expect this method to be a useful tool to extend the versatility of coincident particle detection to arbitrary operation modes of synchrotron radiation facilities and other excitation sources without the need for additional experimental adjustments.