Search Results

Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Item

Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project

2018, Paolozzi, L., Bandi, Y., Benoit, M., Cardarelli, R., Débieux, S., Forshaw, D., Hayakawa, D., Iacobucci, G., Kaynak, M., Miucci, A., Nessi, M., Ratib, O., Ripiccini, E., Rücker, H., Valerio, P., Weber, M.

The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e− RMS and a pulse rise time of less than 2 ns , in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps .

Loading...
Thumbnail Image
Item

Radio Frequency CMOS Chem-bio Viscosity Sensors based on Dielectric Spectroscopy

2017, Guha, Subhajit, Wenger, Christian, Peixoto, Nathalia, Fred, Ana, Gamboa, Hugo, Vaz, Mário

This paper presents a CMOS Radio frequency dielectric sensor platform for the detection of relative viscosity changes in a fluid sample. The operating frequency of the sensor is 12.28 GHz. This frequency range has been chosen for high signal to noise ratio and also to avoid other low frequency dispersion mechanisms for future lab on chip applications. The sensor chip has been fabricated in 250 nm BiCMOS technology of IHP. The measurements conducted to show the relative viscosity variation detection capability of the sensor chip, were based on mixtures of glycerol and water as well as glycerol and organic alcohol. The detection limit of viscosity is dependent on the permittivity contrast of the sample constituent. Therefore, it is also shown the choice of frequency inherently aids in the permittivity contrast of the sample constituents.

Loading...
Thumbnail Image
Item

Verbundvorhaben: MATRIX - Middleware für die Realisierung internetbasierter telemedizinischer Dienste : Schlussbericht ; BMBF-Forschungsvorhaben ; Laufzeit des Vorhabens: 01.04.2009 - 31.12.2011, kostenneutral verlängert bis 31.03.2012

2012, Ortmann, Steffen, Maaser, Michael, Maye, Oliver

[no abstract available]