Search Results

Now showing 1 - 10 of 13
  • Item
    Evaluating arbitrary strain configurations and doping in graphene with Raman spectroscopy
    (Bristol : IOP Publ., 2017-11-6) Mueller, Niclas S.; Heeg, Sebastian; Peña Alvarez, Miriam; Kusch, Patryk; Wasserroth, Sören; Clark, Nick; Schedin, Fredrik; Parthenios, John; Papagelis, Konstantinos; Galiotis, Costas; Kalbáč, Martin; Vijayaraghavan, Aravind; Huebner, Uwe; Gorbachev, Roman; Frank, Otakar; Reich, Stephanie
    The properties of graphene depend sensitively on strain and doping affecting its behavior in devices and allowing an advanced tailoring of this material. A knowledge of the strain configuration, i.e. the relative magnitude of the components of the strain tensor, is particularly crucial, because it governs effects like band-gap opening, pseudo-magnetic fields, and induced superconductivity. It also enters critically in the analysis of the doping level. We propose a method for evaluating unknown strain configurations and simultaneous doping in graphene using Raman spectroscopy. In our analysis we first extract the bare peak shift of the G and 2D modes by eliminating their splitting due to shear strain. The shifts from hydrostatic strain and doping are separated by a correlation analysis of the 2D and G frequencies, where we find Delta omega(2D)/Delta omega(G) = 2.21 +/- 0.05 for pure hydrostatic strain. We obtain the local hydrostatic strain, shear strain and doping without any assumption on the strain configuration prior to the analysis, as we demonstrate for two model cases: Graphene under uniaxial stress and graphene suspended on nanostructures that induce strain. Raman scattering with circular corotating polarization is ideal for analyzing frequency shifts, especially for weak strain when the peak splitting by shear strain cannot be resolved.
  • Item
    Hollow square core fiber sensor for physical parameters measurement
    (Bristol : IOP Publ., 2022) Pereira, Diana; Bierlich, Jörg; Kobelke, Jens; Ferreira, Marta S.
    The measurement of physical parameters is important in many current applications, since they often rely on these measurands to operate with the due quality and the necessary safety. In this work, a simple and robust optical fiber sensor based on an antiresonant hollow square core fiber (HSCF) is proposed to measure simultaneously temperature, strain, and curvature. The proposed sensor was designed in a transmission configuration where a segment of HSCF, with a 10 mm length, was spliced between two single mode fibers. In this sensor, a cladding modal interference (CMI) and a Mach-Zehnder interference (MZI) are enhanced along with the antiresonance (AR) guidance. All the present mechanisms exhibit different responses towards the physical parameters. For the temperature, sensitivities of 32.8 pm/°C, 18.9 pm/°C, and 15.7 pm/°C were respectively attained for the MZI, AR, and CMI. As for the strain, sensitivities of 0.45 pm/μϵ, -0.93 pm/μϵ, and -2.72 pm/μϵ were acquired for the MZI, AR and CMI respectively. Meanwhile, for the curvature measurements, two regions of analysis were considered. In the first region (0 m-1 - 0.7 m-1) sensitivities of 0.033 nm/m-1, -0.27 nm/m-1, and -2.21 nm/m-1 were achieved, whilst for the second region (0.7 m-1 - 1.5 m-1) sensitivities of 0.067 nm/m-1, -0.63 nm/m-1, and -0.49 nm/m-1 were acquired for the MZI, AR and CMI, respectively.
  • Item
    Correlations between the structure and superconducting properties of MT-YBaCuO
    (Bristol : IOP Publ., 2020) Prikhna, T.A.; Moshchill, V.E.; Rabier, J.; Chaud, X.; Joulain, A.; Pan, A.V.; Litskendorf, D.; Habisreuther, T.
    Comprehensive experimental results of fully oxidized (up to YBa2Cu3O6,9-7) melt-Textured YBaCuO materials with different microstructures are presented. These microstructures are built respectively: (1) with a high dislocations density but almost without twins (after high temperature treatment at 2 GPa) and (2) with a high twin density, but practically free from dislocations and stacking faults (after high temperature oxygenation at 10-16 MPa). It is shown that for attaining high critical current densities and fields of irreversibility (jc(H-c, 0 T)=9•104 A/cm2, H irr=9.7 T at 77 K), a high twin density in YBa2Cu3O6.9-7 matrix of MT-YBCO is required. The density of twins in fully oxidized materials depends on the distances between Y2BaCuO5 inclusions, larger twin densities are related to shorter distances between inclusions. The influence of phase composition of the initial powder mixtures on the distances between Y2BaCuO5 inclusions have been characterized and discussed. © Published under licence by IOP Publishing Ltd.
  • Item
    Advances in bioimaging - Challenges and potentials
    (Bristol : IOP Publ., 2018) Eggeling, Christian
    [No abstract available]
  • Item
    Complementary studies of lipid membrane dynamics using iSCAT and super-resolved fluorescence correlation spectroscopy
    (Bristol : IOP Publ., 2018) Reina, Francesco; Galiani, Silvia; Shrestha, Dilip; Sezgin, Erdinc; de Wit, Gabrielle; Cole, Daniel; Christoffer Lagerholm, B.; Kukura, Philipp; Eggeling, Christian
    Observation techniques with high spatial and temporal resolution, such as single-particle tracking based on interferometric scattering (iSCAT) microscopy, and fluorescence correlation spectroscopy applied on a super-resolution STED microscope (STED-FCS), have revealed new insights of the molecular organization of membranes. While delivering complementary information, there are still distinct differences between these techniques, most prominently the use of fluorescent dye tagged probes for STED-FCS and a need for larger scattering gold nanoparticle tags for iSCAT. In this work, we have used lipid analogues tagged with a hybrid fluorescent tag–gold nanoparticle construct, to directly compare the results from STED-FCS and iSCAT measurements of phospholipid diffusion on a homogeneous supported lipid bilayer (SLB). These comparative measurements showed that while the mode of diffusion remained free, at least at the spatial (>40 nm) and temporal (50  ⩽  t  ⩽  100 ms) scales probed, the diffussion coefficient was reduced by 20- to 60-fold when tagging with 20 and 40 nm large gold particles as compared to when using dye tagged lipid analogues. These FCS measurements of hybrid fluorescent tag–gold nanoparticle labeled lipids also revealed that commercially supplied streptavidin-coated gold nanoparticles contain large quantities of free streptavidin. Finally, the values of apparent diffusion coefficients obtained by STED-FCS and iSCAT differed by a factor of 2–3 across the techniques, while relative differences in mobility between different species of lipid analogues considered were identical in both approaches. In conclusion, our experiments reveal that large and potentially cross-linking scattering tags introduce a significant slow-down in diffusion on SLBs but no additional bias, and our labeling approach creates a new way of exploiting complementary information from STED-FCS and iSCAT measurements.
  • Item
    Process flow to integrate nanostructures on silicon grass in surface micromachined systems
    (Bristol : IOP Publ., 2016) Mehner, H.; Müller, L.; Biermann, S.; Hänschke, F.; Hoffmann, M.
    The process flow to integrate metallic nanostructures in surface micromachining processes is presented. The nanostructures are generated by evaporation of microstructured silicon grass with metal. The process flow is based on the lift-off of a thin amorphous silicon layer deposited using a CVD process. All steps feature a low temperature load beneath 120 °C and high compatibility with many materials as only well-established chemicals are used. As a result metallic nanostructures usable for optical applications can be generated as part of multilayered microsystems fabricated in surface micromachining.
  • Item
    Capillary based hybrid fiber sensor in a balloon-like shape for simultaneous measurement of displacement and temperature
    (Bristol : IOP Publ., 2022) Santos, João P.; Bierlich, Jörg; Kobelke, Jens; Ferreira, Marta S.
    In this work, a hybrid sensor based on a silica capillary in a balloon-like shape for simultaneous measurement of displacement and temperature is proposed for the first time, to the best of our knowledge. The sensor is fabricated by splicing a segment of a hollow core fiber between two single mode fibers (SMF) and by bending the fiber in a balloon shape with the capillary at the top-center position. In a transmission scheme, the SMF-capillary-SMF configuration excites an antiresonant (AR) guidance and the balloon shape enhances a Mach-Zehnder interferometer (MZI). The different responses of the interferometers to external displacement and temperature variations are conducive to a hybrid application of the sensor for simultaneous measurement of these parameters. Experimental results show that, for a capillary length of 1.2 cm and a balloon length of 4 cm, AR is insensitive to displacement and its sensitivity to temperature is 14.3 pm/°C, while the MZI has a sensitivity to displacement of 1.68 nm/mm and twice the sensitivity of AR to temperature, of 28.6 pm/°C. The proposed fiber sensor consists of only one sensing element in one configuration exciting two interferometers at the same time, which makes it of simple fabrication as well as low cost.
  • Item
    Magnetooptical response of permalloy multilayer structures on different substrate in the IR-VIS-UV spectral range
    (Bristol : IOP Publ., 2019) Patra, Rajkumar; Mattheis, Roland; Stöcker, Hartmut; Monecke, Manuel; Salvan, Georgeta; Schäfer, Rudolf; Schmidt, Oliver G.; Schmidt, Heidemarie
    The magnetooptical (MO) response of Ru/Py/Ta thin film stacks with 4, 8, and 17 nm thick Ni81Fe19 permalloy (Py) films on a SiO2/Si and a ZnO substrate was measured by vector magnetooptical generalized ellipsometry. The MO response from VMOGE was modelled using a 4  ×  4 Mueller matrix algorithm. The wavelength-dependent, substrate-independent and thickness-independent complex MO coupling constant (Q) of Py in the Ru/Py/Ta thin film stacks was extracted by fitting Mueller matrix difference spectra in the spectral range from 300 nm to 1000 nm. Although the composition-dependent saturation magnetization of NixFe1−x alloys (x  =  0.0...1.0), e.g. of Ni81Fe19, is predictable from the two saturation magnetization end points, the MO coupling constant of NixFe1−x is not predictable from the two Q end points. However, in a small alloy range (0.0  <  x  <  0.2 and 0.8  <  x  <  1.0) the composition-dependent Q of NixFe1−x can be interpolated from a sufficiently high number of analyzed NixFe1−x alloys. The available complex MO coupling constants of six different NixFe1−x (x  =  1.0 to 0.0) alloys were used to interpolate MO response of binary NixFe1−x alloys in the range from x  =  0.0 to x  =  1.0.
  • Item
    Charged domains in ferroelectric, polycrystalline yttrium manganite thin films resolved with scanning electron microscopy
    (Bristol : IOP Publ., 2020) Rayapati, Venkata Rao; Bürger, Danilo; Du, Nan; Kowol, Cornelia; Blaschke, Daniel; Stöcker, Hartmut; Matthes, Patrick; Patra, Rajkumar; Skorupa, Ilona; Schulz, Stefan E.; Schmidt, Heidemarie
    We have investigated ferroelectric charged domains in polycrystalline hexagonal yttrium manganite thin films (Y1Mn1O3, Y0.95Mn1.05O3, Y1Mn0.99Ti0.01O3, and Y0.94Mn1.05Ti0.01O3) by scanning electron microscopy (SEM) in secondary electron emission mode with a small acceleration voltage. Using SEM at an acceleration voltage of 1.0 kV otherwise homogenous surface charging effects are reduced, polarization charges can be observed and polarization directions (±Pz) of the ferroelectric domains in the polycrystalline thin films can be identified. Thin films of different chemical composition have been deposited by pulsed laser deposition on Pt/SiO2/Si structures under otherwise same growth conditions. Using SEM it has been shown that different charged domain density networks are existing in polycrystalline yttrium manganite thin films. © 2020 IOP Publishing Ltd.
  • Item
    High photon count rates improve the quality of super-resolution fluorescence fluctuation spectroscopy
    (Bristol : IOP Publ., 2020) Schneider, Falk; Hernandez-Varas, Pablo; Lagerholm, B. Christoffer; Shrestha, Dilip; Sezgin, Erdinc; Roberti, M. Julia; Ossato, Giulia; Hecht, Frank; Eggeling, Christian; Urbančič, Iztok
    Probing the diffusion of molecules has become a routine measurement across the life sciences, chemistry and physics. It provides valuable insights into reaction dynamics, oligomerisation, molecular (re-)organisation or cellular heterogeneities. Fluorescence correlation spectroscopy (FCS) is one of the widely applied techniques to determine diffusion dynamics in two and three dimensions. This technique relies on the temporal autocorrelation of intensity fluctuations but recording these fluctuations has thus far been limited by the detection electronics, which could not efficiently and accurately time-tag photons at high count rates. This has until now restricted the range of measurable dye concentrations, as well as the data quality of the FCS recordings, especially in combination with super-resolution stimulated emission depletion (STED) nanoscopy. Here, we investigate the applicability and reliability of (STED-)FCS at high photon count rates (average intensities of more than 1 MHz) using novel detection equipment, namely hybrid detectors and real-time gigahertz sampling of the photon streams implemented on a commercial microscope. By measuring the diffusion of fluorophores in solution and cytoplasm of live cells, as well as in model and cellular membranes, we show that accurate diffusion and concentration measurements are possible in these previously inaccessible high photon count regimes. Specifically, it offers much greater flexibility of experiments with biological samples with highly variable intensity, e.g. due to a wide range of expression levels of fluorescent proteins. In this context, we highlight the independence of diffusion properties of cytosolic GFP in a concentration range of approx. 0.01-1 µm. We further show that higher photon count rates also allow for much shorter acquisition times, and improved data quality. Finally, this approach also pronouncedly increases the robustness of challenging live cell STED-FCS measurements of nanoscale diffusion dynamics, which we testify by confirming a free diffusion pattern for a fluorescent lipid analogue on the apical membrane of adherent cells. © The Author(s). Published by IOP Publishing Ltd.