Search Results

Now showing 1 - 3 of 3
  • Item
    Chemical mass balance of 300 °c non-volatile particles at the tropospheric research site Melpitz, Germany
    (München : European Geopyhsical Union, 2014) Poulain, L.; Birmili, W.; Canonaco, F.; Crippa, M.; Wu, Z.J.; Nordmann, S.; Wiedensohler, A.; Held, A.; Spindler, G.; Prévôt, A.S.H.; Wiedensohler, A.; Herrmann, H.
    In the fine-particle mode (aerodynamic diameter < 1 μm) non-volatile material has been associated with black carbon (BC) and low-volatile organics and, to a lesser extent, with sea salt and mineral dust. This work analyzes non-volatile particles at the tropospheric research station Melpitz (Germany), combining experimental methods such as a mobility particle-size spectrometer (3–800 nm), a thermodenuder operating at 300 °C, a multi-angle absorption photometer (MAAP), and an aerosol mass spectrometer (AMS). The data were collected during two atmospheric field experiments in May–June 2008 as well as February–March 2009. As a basic result, we detected average non-volatile particle–volume fractions of 11 ± 3% (2008) and 17 ± 8% (2009). In both periods, BC was in close linear correlation with the non-volatile fraction, but not sufficient to quantitatively explain the non-volatile particle mass concentration. Based on the assumption that BC is not altered by the heating process, the non-volatile particle mass fraction could be explained by the sum of black carbon (47% in summer, 59% in winter) and a non-volatile organic contribution estimated as part of the low-volatility oxygenated organic aerosol (LV-OOA) (53% in summer, 41% in winter); the latter was identified from AMS data by factor analysis. Our results suggest that LV-OOA was more volatile in summer (May–June 2008) than in winter (February–March 2009) which was linked to a difference in oxidation levels (lower in summer). Although carbonaceous compounds dominated the sub-μm non-volatile particle mass fraction most of the time, a cross-sensitivity to partially volatile aerosol particles of maritime origin could be seen. These marine particles could be distinguished, however from the carbonaceous particles by a characteristic particle volume–size distribution. The paper discusses the uncertainty of the volatility measurements and outlines the possible merits of volatility analysis as part of continuous atmospheric aerosol measurements.
  • Item
    Atmospheric black carbon and warming effects influenced by the source and absorption enhancement in central Europe
    (München : European Geopyhsical Union, 2014) Nordmann, S.; Cheng, Y.F.; Carmichael, G.R.; Yu, M.; van der Gon, H.A.C.Denier; Zhang, Q.; Saide, P.E.; Pöschl, U.; Su, H.; Birmili, W.; Wiedensohler, A.
    Particles containing black carbon (BC), a strong absorbing substance, exert a rather uncertain direct and indirect radiative forcing in the atmosphere. To investigate the mass concentration and absorption properties of BC particles over central Europe, the model WRF-Chem was used at a resolution of 12 km in conjunction with a high-resolution BC emission inventory (EUCAARI 42-Pan-European Carbonaceous Aerosol Inventory; 1/8° × 1/16°). The model simulation was evaluated using measurements of equivalent soot carbon, absorption coefficients and particle number concentrations at seven sites within the German Ultrafine Aerosol Network, PM mass concentrations from the dense measurement network of the German Federal Environmental Agency at 392 monitoring stations, and aerosol optical depth from MODIS and AERONET. A distinct time period (25 March to 10 April 2009) was chosen, during which the clean marine air mass prevailed in the first week and afterwards the polluted continental air mass mainly from the southeast dominated with elevated daily average BC concentration of up to 4 μ g m−3. The simulated PM mass concentration, aerosol number concentration and optical depth were in good agreement with the observations, while the modelled BC mass concentrations were found to be a factor of 2 lower than the observations. Together with back trajectories, detailed model bias analyses suggested that the current BC emission in countries to the east and south of Germany might be underestimated by a factor of 5, at least for the simulation period. Running the model with upscaled BC emissions in these regions led to a smaller model bias and a better correlation between model and measurement. In contrast, the particle absorption coefficient was positively biased by about 20% even when the BC mass concentration was underestimated by around 50%. This indicates that the internal mixture treatment of BC in the WRF-Chem optical calculation is unrealistic in our case, which overamplifies the light absorption by BC-containing particles. By adjusting the modelled mass absorption cross-section towards the measured values, the simulation of particle light absorption of BC was improved as well. Finally, the positive direct radiative forcing of BC particles at the top of the atmosphere was estimated to be in the range of 0 to +4 W m−2 over Germany for the model run with improved BC mass concentration and adjusted BC light absorption cross-section. This adjustment lowered the positive forcing of BC by up to 70%, compared with the internal mixing treatment of BC in the model simulation.
  • Item
    Variability of black carbon mass concentrations, sub-micrometer particle number concentrations and size distributions: results of the German Ultrafine Aerosol Network ranging from city street to High Alpine locations
    (Amsterdam [u.a.] : Elsevier Science, 2018) Sun, J.; Birmili, W.; Hermann, M.; Tuch, T.; Weinhold, K.; Spindler, G.; Schladitz, A.; Bastian, S.; Löschau, G.; Cyrys, J.; Gu, J.; Flentje, H.; Briel, B.; Asbac, C.; Kaminski, H.; Ries, L.; Sohme, R.; Gerwig, H.; Wirtz, K.; Meinhardt, F.; Schwerin, A.; Bath, O.; Ma, N.; Wiedensohler, A.
    This work reports the first statistical analysis of multi-annual data on tropospheric aerosols from the German Ultrafine Aerosol Network (GUAN). Compared to other networks worldwide, GUAN with 17 measurement locations has the most sites equipped with particle number size distribution (PNSD) and equivalent black carbon (eBC) instruments and the most site categories in Germany ranging from city street/roadside to High Alpine. As we know, the variations of eBC and particle number concentration (PNC) are influenced by several factors such as source, transformation, transport and deposition. The dominant controlling factor for different pollutant parameters might be varied, leading to the different spatio-temporal variations among the measured parameters. Currently, a study of spatio-temporal variations of PNSD and eBC considering the influences of both site categories and spatial scale is still missing. Based on the multi-site dataset of GUAN, the goal of this study is to investigate how pollutant parameters may interfere with spatial characteristics and site categories. © 2019 The Authors