Search Results

Now showing 1 - 2 of 2
  • Item
    Application of adiabatic pulses for magnetic Resonance Sounding – Pulse shapes and resolution
    (Amsterdam [u.a.] : Elsevier Science, 2020) Dlugosch, Raphael; Müller-Petke, Mike
    Magnetic Resonance Sounding (MRS) can image the spatial distribution of hydrologically relevant parameters in in the subsurface. However, the application of MRS is often limited by its low signal-to-noise ratio. The use of adiabatic excitation pulses show promising features to overcome this limitation. In this work, we study practical considerations when applying adiabatic pulses for MRS, i.e. calculation of the sensitivity kernel for varying pulse shapes and vertical resolution. The pulse shape is crucial for the performance of adiabatic pulses. We investigate the shapes of adiabatic pulses recorded during a MRS and observe small systematic deviations from the theoretical predicted pulse shape and variations between different pulse strengths. We show that the overall impact on the obtained sounding curve and inversion result was small. This enables to limit the time consuming modelling of the spin dynamic to one representative pulse shape, which significantly speeds up the calculation of the sensitivity kernel, necessary for the interpretation of MRS. Additionally, we show that on-resonance excitation generally outperforms adiabatic excitation concerning vertical resolution and depth of investigation (both up to a factor of two). This is true for a wide range of noise conditions. For a very shallow depth interval compared to the loop size, however, adiabatic excitation features improved imaging capabilities. © 2020 The Authors
  • Item
    Evaluation of single-sided nuclear magnetic resonance technology for usage in geosciences
    (Bristol : IOP Publ. Ltd., 2022) Costabel, Stephan; Hiller, Thomas; Dlugosch, Raphael; Kruschwitz, Sabine; Müller-Petke, Mike
    Because of its mobility and ability to investigate exposed surfaces, single-sided (SiS) nuclear magnetic resonance (NMR) technology enables new application fields in geosciences. To test and assess its corresponding potential, we compare longitudinal (T 1) and transverse (T 2) data measured by SiS NMR with those of conventional geoscientific laboratory NMR. We use reference sandstone samples covering a broad range of pore sizes. Our study demonstrates that the lower signal-to-noise ratio of SiS NMR data generally tends to slightly overestimated widths of relaxation time distributions and consequently pore size distributions. While SiS and conventional NMR produce very similar T 1 relaxation data, unbiased SiS NMR results for T 2 measurements can only be expected for fine material, i.e. clayey or silty sediments and soils with main relaxation times below 0.05s . This limit is given by the diffusion relaxation rate due to the gradient in the primary magnetic field associated with the SiS NMR. Above that limit, i.e. for coarse material, the relaxation data is strongly attenuated. If considering the diffusion relaxation time of 0.2 s in the numerical data inversion process, the information content >0.2s is blurred over a range larger than that of conventional NMR. However, our results show that principle range and magnitudes of the relaxation time distributions are reconstructed to some extent. Regarding these findings, SiS NMR can be helpful to solve geoscientific issues, e.g. to assess the hydro-mechanical properties of the walls of underground facilities or to provide local soil moisture data sets for calibrating indirect remote techniques on the regional scale. The greatest opportunity provided by the SiS NMR technology is the acquisition of profile relaxation data for rocks with significant bedding structures at the μm scale. With this unique feature, SiS NMR can support the understanding and modeling of hydraulic and diffusional anisotropy behavior of sedimentary rocks.