Search Results

Now showing 1 - 3 of 3
  • Item
    Semi-Interpenetrating Polymer Networks Based on N-isopropylacrylamide and 2-acrylamido-2-methylpropane Sulfonic Acid for Intramolecular Force-Compensated Sensors
    (Bristol : IOP Publishing, 2021) Binder, Simon; Zschoche, Stefan; Voit, Brigitte; Gerlach, Gerald
    Stimulus-responsive hydrogels are swellable polymers that take up a specific volume depending on a measured variable present in solution. Hydrogel-based chemical sensors make use of this ability by converting the resulting swelling pressure, which depends on the measured variable, into an electrical value. Due to the tedious swelling processes, the measuring method of intramolecular force compensation is used to suppress these swelling processes and, thus, significantly increase the sensor's response time. However, intramolecular force compensation requires a bisensitive hydrogel. In addition to the sensitivity of the measured variable the gel has to provide a second sensitivity for intrinsic compensation of the swelling pressure. At the same time, this hydrogel has to meet further requirements, e.g. high compressive strength. Until now, interpenetrating polymer networks (IPN) have been used for such a force-compensatory effective hydrogel, which are complex to manufacture. In order to significantly simplify the sensor design and production, a simpler synthesis of the bisensitive hydrogel is desirable. This paper presents a new bisensitive hydrogel based on semi-interpenetrating polymer networks. It is based on a copolymer network consisting of N-isopropylacrylamide (NiPAAm) and 2-acrylamido-2-methylpropane sulfonic acid (AMPS) and long PAMPS strands that permeate it. Measurements show, that this hydrogel meets all essential requirements for intramolecular force compensation and is at the same time much easier to synthesize than previously used IPN hydrogels. © 2021 The Author(s).
  • Item
    Employing electro-mechanical analogies for co-resonantly coupled cantilever sensors
    (München : European Geopyhsical Union, 2016) Körner, Julia; Reiche, Christopher F.; Büchner, Bernd; Mühl, Thomas; Gerlach, Gerald
    Understanding the behaviour of mechanical systems can be facilitated and improved by employing electro-mechanical analogies. These analogies enable the use of network analysis tools as well as purely analytical treatment of the mechanical system translated into an electric circuit. Recently, we developed a novel kind of sensor set-up based on two coupled cantilever beams with matched resonance frequencies (co-resonant coupling) and possible applications in magnetic force microscopy and cantilever magnetometry. In order to analyse the sensor's behaviour in detail, we describe it as an electric circuit model. Starting from a simplified coupled harmonic oscillator model with neglected damping, we gradually increase the complexity of the system by adding damping and interaction elements. For each stage, various features of the coupled system are discussed and compared to measured data obtained with a co-resonant sensor. Furthermore, we show that the circuit model can be used to derive sensor parameters which are essential for the evaluation of measured data. Finally, the much more complex circuit representation of a bending beam is discussed, revealing that the simplified circuit model of a coupled harmonic oscillator is a very good representation of the sensor system.
  • Item
    Signal enhancement in cantilever magnetometry based on a co-resonantly coupled sensor
    (Frankfurt, M. : Beilstein-Institut zur Förderung der Chemischen Wissenschaften, 2016) Körner, Julia; Reiche, Christopher F.; Gemming, Thomas; Büchner, Bernd; Gerlach, Gerald; Mühl, Thomas
    Cantilever magnetometry is a measurement technique used to study magnetic nanoparticles. With decreasing sample size, the signal strength is significantly reduced, requiring advances of the technique. Ultrathin and slender cantilevers can address this challenge but lead to increased complexity of detection. We present an approach based on the co-resonant coupling of a micro- and a nanometer-sized cantilever. Via matching of the resonance frequencies of the two subsystems we induce a strong interplay between the oscillations of the two cantilevers, allowing for a detection of interactions between the sensitive nanocantilever and external influences in the amplitude response curve of the microcantilever. In our magnetometry experiment we used an iron-filled carbon nanotube acting simultaneously as nanocantilever and magnetic sample. Measurements revealed an enhancement of the commonly used frequency shift signal by five orders of magnitude compared to conventional cantilever magnetometry experiments with similar nanomagnets. With this experiment we do not only demonstrate the functionality of our sensor design but also its potential for very sensitive magnetometry measurements while maintaining a facile oscillation detection with a conventional microcantilever setup.