Search Results

Now showing 1 - 3 of 3
  • Item
    Opinion paper : Measuring livestock robustness and resilience : are we on the right track?
    (Amsterdam : Elsevier, 2019) Llonch, P.; Hoffmann, G.; Bodas, R.; Mirbach, D.; Verwer, C.; Haskell, M.J.
    [No abstract available]
  • Item
    The suitability of infrared temperature measurements for continuous temperature monitoring in gilts
    (Göttingen : Copernicus, 2014) Schmidt, M.; Ammon, C.; Schön, P.C.; Manteuffel, C.; Hoffmann, G.
    The aim of this study was to evaluate whether an infrared thermometer, a pyrometer, could detect the body surface temperature in the orbital area of gilts without contacting them. Furthermore, it was tested whether an increase in the gilts' temperatures could be detected. Therefore, fever was induced. During 11 trials, 43 German Landrace gilts were injected with either a Porcilis AR-T DF (Intervet International B.V., Boxmeer, Netherlands) vaccine or 2 ml of 0.9 % NaCl. A commercial temperature logger (TRIX-8, LogTag Recorders, Auckland, New Zealand) was placed in the vagina to record temperature data every 3 min. The pyrometer (optris cs, Optris, Berlin, Germany) was aimed at where the orbital area of the gilts would be. While they were drinking, temperature measurements were done in that site by the pyrometer. Time periods from 0.25 to 6 h were analysed. Considering the 0.25-h period, a positive correlation (ρ=0.473) between temperatures of the logger and the pyrometer was found for 15 of 39 gilts. The longer the chosen measuring period was, the fewer animals showed a significant correlation between the two temperatures. In contrast to the vaginal logger, the pyrometer cannot detect an increase in the body temperature in all fever-induced gilts. In conclusion, a pyrometer cannot detect the body surface temperature reliably. An increase in the body surface temperature over a short time period (on average 5 h) could not be detected by the pyrometer. The temperature increase measured using the pyrometer was too low and time-delayed compared to the temperature detected by the vaginal logger.
  • Item
    Sensor-based detection of the severity of hyperkeratosis in the teats of dairy cows
    (Basel : MDPI AG, 2018) Demba, S.; Hoffmann, G.; Ammon, C.; Rose-Meierhöfer, S.
    The aim of this study was to evaluate whether the severity of hyperkeratosis (HK) in the teats of dairy cows can be assessed by a dielectric measurement. The study focused on surveying the occurrence of hyperkeratosis in a total of 241 teats of lactating dairy cows. A scoring system consisting of four categories was used to macroscopically assess the severity of HK. Additionally, the dielectric constant (DC) of all teats with milkability was measured in a double iteration with the MoistureMeterD (Delfin Technologies, Kuopio, Finland) on four different days. The Spearman rank correlation coefficient revealed a negative correlation between the DC and HK score (rs = −0.55 to −0.36). The results of the regression analysis showed that the DC values differed significantly between healthy teat ends (≤2) and teat ends with HK (≥3). Thus, the non-invasive measurement of DC provides a promising method of objectively assessing the occurrence and severity of HK.