Ultrafast intermodal third harmonic generation in a liquid core step-index fiber filled with C2Cl4: erratum

2021, Schaarschmidt, Kay, Kobelke, Jens, Nolte, Stefan, Meyer, Tobias, Schmidt, Markus A.

We provide a correction due to an erroneous repetition rate of one of the laser systems (90 fs pulse duration) in our previously published paper [Opt. Express28, 25037 (2020)10.1364/OE.399771].

Loading...
Thumbnail Image
Item

(INVITED)Tm:YAG crystal-derived double-clad fibers – A hybrid approach towards high gain and high efficiency Tm lasers

2022, Leich, Martin, Müller, Robert, Unger, Sonja, Schwuchow, Anka, Dellith, Jan, Lorenz, Adrian, Kobelke, Jens, Jäger, Matthias

The hybrid approach of combining a Tm:YAG laser crystal with an amorphous fused silica tube is investigated to evaluate the suitability of the resulting crystal-derived fibers for efficient double-clad fiber lasers. The fabrication process and fiber properties of these Tm fibers are investigated, focusing on the dependence of the active fiber properties on the incorporated Tm3+ concentration. Crystal rods with different doping concentrations (TmxY1-x)3Al5O12 (x = 0.02, 0.05 and 0.08) were used as starting core material for fiber drawing. The investigated fibers are mechanically stable and result in a fairly homogenous and amorphous core glass with optical absorption and emission spectra that are similar to conventional Tm:Al doped silica fibers. Regarding laser properties with 790 nm cladding pumping, we could achieve a maximum slope efficiency of 47% with an output power of 4 W. The fiber laser results are compared to a conventionally fabricated double-clad Tm fiber prepared by Modified Chemical Vapor Deposition and solution doping. To the best of our knowledge, we demonstrate the highest laser output and the highest efficiency obtained from a Tm:YAG crystal-derived fiber.

Loading...
Thumbnail Image
Item

Negative curvature hollow core fiber sensor for the measurement of strain and temperature

2021, Ferreira, Marta S., Bierlich, Jörg, Kobelke, Jens, Pinto, João L., Wondraczek, Katrin

Three different types of strain and temperature sensors based on negative curvature hollow core fiber (NCHCF) are proposed. Each sensor is produced by splicing a small section of the NCHCF between two sections of single mode fiber. Different types of interferometers are obtained simply by changing the splicing conditions. The first sensor consists on a single Fabry-Perot interferometer (FPI). The remaining two configurations are attained with the same sensing structure, depending on its position in relation to the interrogation setup. Thus, a double FPI or a hybrid sensor, the latter being composed by an FPI and a Michelson interferometer, are formed. The inline sensors are of submillimeter size, thus enabling nearly punctual measurements.

Loading...
Thumbnail Image
Item

Fiber Fabry-Perot interferometer for curvature sensing

2016, Monteiro, Catarina S., Ferreira, Marta S., Silva, Susana O., Kobelke, Jens, Schuster, Kay, Bierlich, Jörg, Frazão, Orlando

A curvature sensor based on an Fabry-Perot (FP) interferometer was proposed. A capillary silica tube was fusion spliced between two single mode fibers, producing an FP cavity. Two FP sensors with different cavity lengths were developed and subjected to curvature and temperature. The FP sensor with longer cavity showed three distinct operating regions for the curvature measurement. Namely, a linear response was shown for an intermediate curvature radius range, presenting a maximum sensitivity of 68.52 pm/m-1. When subjected to temperature, the sensing head produced a similar response for different curvature radii, with a sensitivity varying from 0.84 pm/°C to 0.89 pm/°C, which resulted in a small cross-sensitivity to temperature when the FP sensor was subjected to curvature. The FP cavity with shorter length presented low sensitivity to curvature.

Loading...
Thumbnail Image
Item

Ultrafast intermodal third harmonic generation in a liquid core step-index fiber filled with C2Cl4

2020, Schaarschmidt, Kay, Kobelke, Jens, Nolte, Stefan, Meyer, Tobias, Schmidt, Markus A.

Third harmonic generation in a circular liquid core step-index fiber filled with a highly transparent inorganic solvent is demonstrated experimentally using ultrafast pump pulses of different durations in the telecom domain for the first time. Specifically we achieve intermodal phase matching to the HE13 higher order mode at the harmonic wavelength and found clear indications of a non-instantaneous molecular contribution to the total nonlinearity in the spectral broadening of the pump. Spectral power evolution and efficiency of the conversion process is studied for all pulse parameters, while we found the greatest photon yield for the longest pulses as well as an unexpected blue-shift of the third harmonic wavelength with increasing pump power. Our results provide the basis for future studies aiming at using this tunable fiber platform with a sophisticated nonlinear response in the context of harmonic generation. © 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Loading...
Thumbnail Image
Item

Three-dimensional spatiotemporal tracking of nano-objects diffusing in water-filled optofluidic microstructured fiber

2020, Jiang, Shiqi, Förster, Ronny, Plidschun, Malte, Kobelke, Jens, Ando, Ron Fatobene, Schmidt, Markus A.

Three-dimensional (3D) tracking of nano-objects represents a novel pathway for understanding dynamic nanoscale processes within bioanalytics and life science. Here we demonstrate 3D tracking of diffusing 100 nm gold nanosphere within a water-filled optofluidic fiber via elastic light scattering-based position retrieval. Specifically, the correlation between intensity and position inside a region of a fiber-integrated microchannel has been used to decode the axial position from the scattered intensity, while image processing-based tracking was used in the image plane. The 3D trajectory of a diffusing gold nanosphere has been experimentally determined, while the determined diameter analysis matches expectations. Beside key advantages such as homogenous light-line illumination, low-background scattering, long observation time, large number of frames, high temporal and spatial resolution and compatibility with standard microscope, the particular properties of operating with water defines a new bioanalytical platform that is highly relevant for medical and life science applications. © 2020 Shiqi Jiang et al., published by De Gruyter. 2020.