Search Results

Now showing 1 - 4 of 4
  • Item
    Squalenyl Hydrogen Sulfate Nanoparticles for Simultaneous Delivery of Tobramycin and an Alkylquinolone Quorum Sensing Inhibitor Enable the Eradication of P. aeruginosa Biofilm Infections
    (Weinheim : Wiley-VCH Verlag, 2020) Ho, D.-K.; Murgia, X.; De Rossi, C.; Christmann, R.; Hüfner de Mello Martins, A.G.; Koch, M.; Andreas, A.; Herrmann, J.; Müller, R.; Empting, M.; Hartmann, R.W.; Desmaele, D.; Loretz, B.; Couvreur, P.; Lehr, C.-M.
    Elimination of pulmonary Pseudomonas aeruginosa (PA) infections is challenging to accomplish with antibiotic therapies, mainly due to resistance mechanisms. Quorum sensing inhibitors (QSIs) interfering with biofilm formation can thus complement antibiotics. For simultaneous and improved delivery of both active agents to the infection sites, self-assembling nanoparticles of a newly synthesized squalenyl hydrogen sulfate (SqNPs) were prepared. These nanocarriers allowed for remarkably high loading capacities of hydrophilic antibiotic tobramycin (Tob) and a novel lipophilic QSI at 30 % and circa 10 %, respectively. The drug-loaded SqNPs showed improved biofilm penetration and enhanced efficacy in relevant biological barriers (mucin/human tracheal mucus, biofilm), leading to complete eradication of PA biofilms at circa 16-fold lower Tob concentration than Tob alone. This study offers a viable therapy optimization and invigorates the research and development of QSIs for clinical use.
  • Item
    Towards hybrid one-pot/one-electrode Pd-NPs-based nanoreactors for modular biocatalysis
    (Amsterdam [u.a.] : Elsevier, 2021) Koch, M.; Apushkinskaya, N.; Zolotukhina, E.V.; Silina, Y.E.
    Here, fundamental aspects affecting template-assisted engineering of oxidase-associated peroxide oxidation co-catalysis of the modeled microanalytical system based on the hybrid palladium nanoparticles (Pd-NPs) with tailored functional properties were studied. By an accurate tuning and validation of the experimental setup, a modular Pd-NPs-doped one-pot/one-electrode amperometric nanobiosensor for advanced multiplex analyte detection was constructed. The specific operational conditions (electrochemical read-out mode, pH, regeneration procedure) of the modular one-pot/one-electrode nanobiosensor allowed a reliable sensing of L-lactate (with linear dynamic range, LDR = 500 µM – 2 mM, R2 = 0.977), D-glucose (with LDR = 200 µM – 50 mM, R2 = 0.987), hydrogen peroxide (with LDR = 20 µM – 100 mM, R2 = 0.998) and glutaraldehyde (with LDR = 1 – 100 mM, R2 = 0.971). In addition, mechanistic aspects influencing the performance of Pd-NPs-doped one-pot/one-electrode for multiplex analyte sensing were studied in detail. The designed one-pot/one-electrode amperometric nanobiosensor showed a thin layer electrochemical behavior that greatly enhanced electron transfer between the functional hybrid layer and the electrode. Finally, a specific regeneration procedure of the hybrid one-pot/one-electrode and algorithm towards its usage for modular biocatalysis were developed. The reported strategy can readily be considered as a guideline towards the fabrication of commercialized nanobiosensors with tailored properties for advanced modular biocatalysis.
  • Item
    Strength of bacterial adhesion on nanostructured surfaces quantified by substrate morphometry
    (London : Royal Society of Chemistry, 2019) Spengler, C.; Nolle, F.; Mischo, J.; Faidt, T.; Grandthyll, S.; Thewes, N.; Koch, M.; Müller, F.; Bischoff, M.; Klatt, M.A.; Jacobs, K.
    Microbial adhesion and the subsequent formation of resilient biofilms at surfaces are decisively influenced by substrate properties, such as the topography. To date, studies that quantitatively link surface topography and bacterial adhesion are scarce, as both are not straightforward to quantify. To fill this gap, surface morphometry combined with single-cell force spectroscopy was performed on surfaces with irregular topographies on the nano-scale. As surfaces, hydrophobized silicon wafers were used that were etched to exhibit surface structures in the same size range as the bacterial cell wall molecules. The surface structures were characterized by a detailed morphometric analysis based on Minkowski functionals revealing both qualitatively similar features and quantitatively different extensions. We find that as the size of the nanostructures increases, the adhesion forces decrease in a way that can be quantified by the area of the surface that is available for the tethering of cell wall molecules. In addition, we observe a bactericidal effect, which is more pronounced on substrates with taller structures but does not influence adhesion. Our results can be used for a targeted development of 3D-structured materials for/against bio-adhesion. Moreover, the morphometric analysis can serve as a future gold standard for characterizing a broad spectrum of material structures. © The Royal Society of Chemistry 2019.
  • Item
    A tandem of GC-MS and electroanalysis for a rapid chemical profiling of bacterial extracellular matrix
    (Weinheim : Wiley-VCH-Verl., 2023) Silina, Y. E.; Zolotukhina, E. V.; Koch, M.; Fink‐Straube, C.
    Herein an assay toward a rapid and reliable profiling of extracellular matrix of Escherichia coli (E. coli) utilizing a tandem of GC-MS as a tool for definition of the exact chemical nature of low molecular weight compounds and cyclic voltammetry for their high throughput detection is presented. Briefly, during a set of investigations the formation of glycerol in the extracellular matrix (ECM) of E. coli at physiological relevant conditions of cells was revealed. Based on the obtained knowledge, the electrochemical protocol allowing both qualitative and quantitative analyses of glycerol in E. coli ECMs at palladium ink-modified screen printed electrodes with precision values (RSD) <10 % and recovery rates ranged from 98 % to 102 % was proposed. The provided protocol for a rapid electrochemical profiling of the bacterial ECMs can readily be used as a guideline for the controlled electroanalysis of target electroactive signaling analytes in complex biological samples.