Search Results

Now showing 1 - 4 of 4
  • Item
    Integrating Biophysics in Toxicology
    (Basel : MDPI, 2020) Del Favero, G.; Kraegeloh, A.
    Integration of biophysical stimulation in test systems is established in diverse branches of biomedical sciences including toxicology. This is largely motivated by the need to create novel experimental setups capable of reproducing more closely in vivo physiological conditions. Indeed, we face the need to increase predictive power and experimental output, albeit reducing the use of animals in toxicity testing. In vivo, mechanical stimulation is essential for cellular homeostasis. In vitro, diverse strategies can be used to model this crucial component. The compliance of the extracellular matrix can be tuned by modifying the stiffness or through the deformation of substrates hosting the cells via static or dynamic strain. Moreover, cells can be cultivated under shear stress deriving from the movement of the extracellular fluids. In turn, introduction of physical cues in the cell culture environment modulates differentiation, functional properties, and metabolic competence, thus influencing cellular capability to cope with toxic insults. This review summarizes the state of the art of integration of biophysical stimuli in model systems for toxicity testing, discusses future challenges, and provides perspectives for the further advancement of in vitro cytotoxicity studies.
  • Item
    In vitro entero-capillary barrier exhibits altered inflammatory and exosomal communication pattern after exposure to silica nanoparticles
    (Basel : MDPI, 2019) Kasper, J.Y.; Iris, Hermanns, M.; Kraegeloh, A.; Roth, W.; James, Kirkpatrick, C.; Unger, R.E.
    The intestinal microvasculature (iMV) plays multiple pathogenic roles during chronic inflammatory bowel disease (IBD). The iMV acts as a second line of defense and is, among other factors, crucial for the innate immunity in the gut. It is also the therapeutic location in IBD targeting aggravated leukocyte adhesion processes involving ICAM-1 and E-selectin. Specific targeting is stressed via nanoparticulate drug vehicles. Evaluating the iMV in enterocyte barrier models in vitro could shed light on inflammation and barrier-integrity processes during IBD. Therefore, we generated a barrier model by combining the enterocyte cell line Caco-2 with the microvascular endothelial cell line ISO-HAS-1 on opposite sides of a transwell filter-membrane under culture conditions which mimicked the physiological and inflamed conditions of IBD. The IBD model achieved a significant barrier-disruption, demonstrated via transepithelial-electrical resistance (TER), permeability-coefficient (Papp) and increase of sICAM sE-selectin and IL-8. In addition, the impact of a prospective model drug-vehicle (silica nanoparticles, aSNP) on ongoing inflammation was examined. A decrease of sICAM/sE-selectin was observed after aSNP-exposure to the inflamed endothelium. These findings correlated with a decreased secretion of ICAM/E-selectin bearing exosomes/microvesicles, as evaluated via ELISA. Our findings indicate that aSNP treatment of the inflamed endothelium during IBD may hamper exosomal/microvesicular systemic communication. © 2019 by the authors. Licensee MDPI, Basel, Switzerland.
  • Item
    Safe-by-Design part I: Proposal for nanospecific human health safety aspects needed along the innovation process
    (Amsterdam : Elsevier, 2020) Dekkers, S.; Wijnhoven, S.W.P.; Braakhuis, H.M.; Soeteman-Hernandez, L.G.; Sips, A.J.A.M.; Tavernaro, I.; Kraegeloh, A.; Noorlander, C.W.
    Safe-by-Design aims to reduce uncertainties and/or increase the human health and environmental safety from already early in the innovation process onwards and will thereby contribute to increased innovation efficiency, economic viability, interdisciplinary collaboration, consumers trust and improve sustainability. Since most innovators or designers are neither toxicologists nor risk assessors, considering human health safety aspects within their innovation process may be challenging. This paper provides sets of questions that can help innovators to assess nanospecific human health safety aspects of their product or material along the various stages of the innovation process. Addressing these questions will facilitate innovators to identify which type of information may support decisions on how to address potential human health risks in the innovation process. The identified information on the human health safety aspects can help innovators to decide if further investments in the product or material are beneficial. It may allow them to rank, prioritize and choose safer alternatives early in the innovation process. This may enable innovators to better anticipate on potential safety issues in an early stage, preventing these safety issues to become an innovation killer in a later stage of the innovation process. This approach to identify potential nanospecific human health risks should be considered as complementary to current regulations. The applicability of this approach was evaluated using a few industrial case studies. To determine if the approach is applicable to the innovation of a broader group of nanomaterials and nano-enabled products, more experience within various industrial sectors is needed.
  • Item
    Kinetic and spectroscopic responses of pH-sensitive nanoparticles: Influence of the silica matrix
    (London : Royal Society of Chemistry, 2019) Clasen, A.; Wenderoth, S.; Tavernaro, I.; Fleddermann, J.; Kraegeloh, A.; Jung, G.
    Intracellular pH sensing with fluorescent nanoparticles is an emerging topic as pH plays several roles in physiology and pathologic processes. Here, nanoparticle-sized pH sensors (diameter far below 50 nm) for fluorescence imaging have been described. Consequently, a fluorescent derivative of pH-sensitive hydroxypyrene with pKa = 6.1 was synthesized and subsequently embedded in core and core-shell silica nanoparticles via a modified Stöber process. The detailed fluorescence spectroscopic characterization of the produced nanoparticles was carried out for retrieving information about the environment within the nanoparticle core. Several steady-state and time-resolved fluorescence spectroscopic methods hint to the screening of the probe molecule from the solvent, but it sustained interactions with hydrogen bonds similar to that of water. The incorporation of the indicator dye in the water-rich silica matrix neither changes the acidity constant nor dramatically slows down the protonation kinetics. However, cladding by another SiO2 shell leads to the partial substitution of water and decelerating the response of the probe molecule toward pH. The sensor is capable of monitoring pH changes in a physiological range by using ratiometric fluorescence excitation with λex = 405 nm and λex = 488 nm, as confirmed by the confocal fluorescence imaging of intracellular nanoparticle uptake.