Search Results

Now showing 1 - 10 of 18
  • Item
    Rapid isolation and identification of pneumonia associated pathogens from sputum samples combining an innovative sample preparation strategy and array-based detection
    (Washington : American Chemical Society, 2019) Pahlow, Susanne; Lehniger, Lydia; Hentschel, Stefanie; Seise, Barbara; Braun, Sascha D.; Ehricht, Ralf; Berg, Albrecht; Popp, Jürgen; Weber, Karina
    With this study, an innovative and convenient enrichment and detection strategy for eight clinically relevant pneumonia pathogens, namely, Acinetobacter baumannii, Escherichia coli, Haemophilus influenzae, Klebsiella pneumoniae, Moraxella catarrhalis, Pseudomonas aeruginosa, Staphylococcus aureus, and Streptococcus pneumoniae is introduced. Bacteria were isolated from sputum samples with amine-modified particles exploiting pH-dependent electrostatic interactions between bacteria and the functionalized particle surface. Following this, an asymmetric polymerase chain reaction as well as subsequent stringent array-based hybridization with specific complementary capture probes were performed. Finally, results were visualized by an enzyme-induced silver nanoparticle deposition, providing stable endpoint signals and consequently an easy detection possibility. The assay was optimized using spiked samples of artificial sputum with different strains of the abovementioned bacterial species. Furthermore, actual patient sputum samples with S. pneumoniae were successfully analyzed. The presented approach offers great potential for the urgent need of a fast, specific, and reliable isolation and identification platform for important pneumonia pathogens, covering the complete process chain from sample preparation up to array-based detection within only 4 h.With this study, an innovative and convenient enrichment and detection strategy for eight clinically relevant pneumonia pathogens, namely, Acinetobacter baumannii, Escherichia coli, Haemophilus influenzae, Klebsiella pneumoniae, Moraxella catarrhalis, Pseudomonas aeruginosa, Staphylococcus aureus, and Streptococcus pneumoniae is introduced. Bacteria were isolated from sputum samples with amine-modified particles exploiting pH-dependent electrostatic interactions between bacteria and the functionalized particle surface. Following this, an asymmetric polymerase chain reaction as well as subsequent stringent array-based hybridization with specific complementary capture probes were performed. Finally, results were visualized by an enzyme-induced silver nanoparticle deposition, providing stable endpoint signals and consequently an easy detection possibility. The assay was optimized using spiked samples of artificial sputum with different strains of the abovementioned bacterial species. Furthermore, actual patient sputum samples with S. pneumoniae were successfully analyzed. The presented approach offers great potential for the urgent need of a fast, specific, and reliable isolation and identification platform for important pneumonia pathogens, covering the complete process chain from sample preparation up to array-based detection within only 4 h.
  • Item
    Rapid Colorimetric Detection of Pseudomonas aeruginosa in Clinical Isolates Using a Magnetic Nanoparticle Biosensor
    (Washington, DC : ACS Publications, 2019) Alhogail, Sahar; Suaifan, Ghadeer A.R.Y; Bikker, Floris J.; Kaman, Wendy E.; Weber, Karina; Cialla-May, Dana; Popp, Jürgen; Zourob, Mohammed M.
    A rapid, sensitive, and specific colorimetric biosensor based on the use of magnetic nanoparticles (MNPs) was designed for the detection of Pseudomonas aeruginosa in clinical samples. The biosensing platform was based on the measurement of P. aeruginosa proteolytic activity using a specific protease substrate. At the N-terminus, this substrate was covalently bound to MNPs and was linked to a gold sensor surface via cystine at the C-terminus of the substrates. The golden sensor appears black to naked eyes because of the coverage of the MNPs. However, upon proteolysis, the cleaved peptide–MNP moieties will be attracted by an external magnet, revealing the golden color of the sensor surface, which can be observed by the naked eye. In vitro, the biosensor was able to detect specifically and quantitatively the presence of P. aeruginosa with a detection limit of 102 cfu/mL in less than 1 min. The colorimetric biosensor was used to test its ability to detect in situ P. aeruginosa in clinical isolates from patients. This biochip is anticipated to be useful as a rapid point-of-care device for the diagnosis of P. aeruginosa-related infections.
  • Item
    A Machine Learning-Based Raman Spectroscopic Assay for the Identification of Burkholderia mallei and Related Species
    (Basel : MDPI, 2019) Silge, Anja; Moawad, Amira A.; Bocklitz, Thomas; Fischer, Katja; Rösch, Petra; Roesler, Uwe; Elschner, Mandy C.; Popp, Jürgen; Neubauer, Heinrich
    Burkholderia (B.) mallei, the causative agent of glanders, and B. pseudomallei, the causative agent of melioidosis in humans and animals, are genetically closely related. The high infectious potential of both organisms, their serological cross-reactivity, and similar clinical symptoms in human and animals make the differentiation from each other and other Burkholderia species challenging. The increased resistance against many antibiotics implies the need for fast and robust identification methods. The use of Raman microspectroscopy in microbial diagnostic has the potential for rapid and reliable identification. Single bacterial cells are directly probed and a broad range of phenotypic information is recorded, which is subsequently analyzed by machine learning methods. Burkholderia were handled under biosafety level 1 (BSL 1) conditions after heat inactivation. The clusters of the spectral phenotypes and the diagnostic relevance of the Burkholderia spp. were considered for an advanced hierarchical machine learning approach. The strain panel for training involved 12 B. mallei, 13 B. pseudomallei and 11 other Burkholderia spp. type strains. The combination of top- and sub-level classifier identified the mallei-complex with high sensitivities (>95%). The reliable identification of unknown B. mallei and B. pseudomallei strains highlighted the robustness of the machine learning-based Raman spectroscopic assay. © 2019 by the authors
  • Item
    Counterfeit and substandard test of the antimalarial tablet Riamet® by means of Raman hyperspectral multicomponent analysis
    (Basel : MDPI, 2019) Frosch, Timea; Wyrwich, Elisabeth; Yan, Di; Domes, Christian; Domes, Robert; Popp, Jürgen; Frosch, Torsten
    The fight against counterfeit pharmaceuticals is a global issue of utmost importance, as failed medication results in millions of deaths every year. Particularly affected are antimalarial tablets. A very important issue is the identification of substandard tablets that do not contain the nominal amounts of the active pharmaceutical ingredient (API), and the differentiation between genuine products and products without any active ingredient or with a false active ingredient. This work presents a novel approach based on fiber-array based Raman hyperspectral imaging to qualify and quantify the antimalarial APIs lumefantrine and artemether directly and non-invasively in a tablet in a time-efficient way. The investigations were carried out with the antimalarial tablet Riamet® and self-made model tablets, which were used as examples of counterfeits and substandard. Partial least-squares regression modeling and density functional theory calculations were carried out for quantification of lumefantrine and artemether and for spectral band assignment. The most prominent differentiating vibrational signatures of the APIs were presented.
  • Item
    Fiber-array-based Raman hyperspectral imaging for simultaneous chemical selective monitoring of particle size and shape of active ingredients in analgesic tablets
    (Basel : MDPI, 2019) Frosch, Timea; Wyrwich, Elisabeth; Yan, Di; Popp, Jürgen; Frosch, Torsten
    The particle shape, size and distribution of active pharmaceutical ingredients (API) are relevant quality indicators of pharmaceutical tablets due to their high impact on the manufacturing process. Furthermore, the bioavailability of the APIs from the dosage form depends largely on these characteristics. Routinely, particle size and shape are only analyzed in the powder form, without regard to the effect of the formulation procedure on the particle characteristics. The monitoring of these parameters improves the understanding of the process; therefore, higher quality and better control over the biopharmaceutical profile can be ensured. A new fiber-array-based Raman hyperspectral imaging technique is presented for direct simultaneous in-situ monitoring of three different active pharmaceutical ingredients- acetylsalicylic acid, acetaminophen and caffeine- in analgesic tablets. This novel method enables a chemically selective, noninvasive assessment of the distribution of the active ingredients down to 1 µm spatial resolution. The occurrence of spherical and needle-like particles, as well as agglomerations and the respective particle size ranges, were rapidly determined for two commercially available analgesic tablet types. Subtle differences were observed in comparison between these two tablets. Higher amounts of acetaminophen were visible, more needle-shaped and bigger acetylsalicylic acid particles, and a higher incidence of bigger agglomerations were found in one of the analgesic tablets.
  • Item
    corr2D: Implementation of Two-Dimensional Correlation Analysis in R
    (Los Angeles : UCLA, 2019) Geitner, Robert; Fritzsch, Robby; Bocklitz, Thomas W.; Popp, Jürgen
    In the package corr2D two-dimensional correlation analysis is implemented in R. This paper describes how two-dimensional correlation analysis is done in the package and how the mathematical equations are translated into R code. The paper features a simple tutorial with executable code for beginners, insight into the calculations done before the correlation analysis, a detailed look at the parallelization of the fast Fourier transformation based correlation analysis and a speed test of the calculation. The package corr2D offers the possibility to preprocess, correlate and postprocess spectroscopic data using exclusively the R language. Thus, corr2D is a welcome addition to the toolbox of spectroscopists and makes two-dimensional correlation analysis more accessible and transparent.
  • Item
    Nonresonant Raman spectroscopy of isolated human retina samples complying with laser safety regulations for in vivo measurements
    (Bellingham, Wash. : SPIE, 2019) Stiebing, Clara; Schie, Iwan W.; Knorr, Florian; Schmitt, Michael; Keijzer, Nanda; Kleemann, Robert; Jahn, Izabella J.; Jahn, Martin; Kiliaan, Amanda J.; Ginner, Laurin; Lichtenegger, Antonia; Drexler, Wolfgang; Leitgeb, Rainer A.; Popp, Jürgen
    Retinal diseases, such as age-related macular degeneration, are leading causes of vision impairment, increasing in incidence worldwide due to an aging society. If diagnosed early, most cases could be prevented. In contrast to standard ophthalmic diagnostic tools, Raman spectroscopy can provide a comprehensive overview of the biochemical composition of the retina in a label-free manner. A proof of concept study of the applicability of nonresonant Raman spectroscopy for retinal investigations is presented. Raman imaging provides valuable insights into the molecular composition of an isolated ex vivo human retina sample by probing the entire molecular fingerprint, i.e., the lipid, protein, carotenoid, and nucleic acid content. The results are compared to morphological information obtained by optical coherence tomography of the sample. The challenges of in vivo Raman studies due to laser safety limitations and predefined optical parameters given by the eye itself are explored. An in-house built setup simulating the optical pathway in the human eye was developed and used to demonstrate that even under laser safety regulations and the above-mentioned optical restrictions, Raman spectra of isolated ex vivo human retinas can be recorded. The results strongly support that in vivo studies using nonresonant Raman spectroscopy are feasible and that these studies provide comprehensive molecular information of the human retina. © The Authors. Published by SPIE.
  • Item
    Molecular Specific and Sensitive Detection of Pyrazinamide and Its Metabolite Pyrazinoic Acid by Means of Surface Enhanced Raman Spectroscopy Employing In Situ Prepared Colloids
    (Basel : MDPI, 2019) Mühlig, Anna; Jahn, Izabella-Jolan; Heidler, Jan; Weber, Karina; Jahn, Martin; Sheen, Patricia; Zimic, Mirko; Cialla-May, Dana; Popp, Jürgen
    The prodrug pyrazinamide (PZA) is metabolized by the mycobacteria to pyrazinoic acid (POA), which is expelled into the extracellular environment. PZA resistance is highly associated to a lack of POA efflux. Thus, by detecting a reduction of the concentration of POA in the extracellular environment, by means of lab-on-a-chip (LoC)-SERS (surface-enhanced Raman spectroscopy), an alternative approach for the discrimination of PZA resistant mycobacteria is introduced. A droplet-based microfluidic SERS device has been employed to illustrate the potential of the LoC-SERS method for the discrimination of PZA resistant mycobacteria. The two analytes were detected discretely in aqueous solution with a limit of detection of 27 µm for PZA and 21 µm for POA. The simultaneous detection of PZA and POA in aqueous mixtures could be realized within a concentration range from 20 μm to 50 μm for PZA and from 50 μm to 80 μm for POA.
  • Item
    Raman spectroscopy follows time-dependent changes in T lymphocytes isolated from spleen of endotoxemic mice
    (Rockville : American Association of Immunologists, 2019) Ramoji, Anuradha; Ryabchykov, Oleg; Galler, Kerstin; Tannert, Astrid; Markwart, Robby; Requardt, Robert Pascal; Rubio, Ignacio; Bauer, Michael; Bocklitz, Thomas W.; Popp, Jürgen; Neugebauer, Ute
    T lymphocytes (T cells) are highly specialized members of the adaptive immune system and hold the key to the understanding the hosts’ response toward invading pathogen or pathogen-associated molecular patterns such as LPS. In this study, noninvasive Raman spectroscopy is presented as a label-free method to follow LPS-induced changes in splenic T cells during acute and postacute inflammatory phases (1, 4, 10, and 30 d) with a special focus on CD4+ and CD8+ T cells of endotoxemic C57BL/6 mice. Raman spectral analysis reveals highest chemical differences between CD4+ and CD8+ T cells originating from the control and LPS-treated mice during acute inflammation, and the differences are visible up to 10 d after the LPS insult. In the postacute phase, CD4+ and CD8+ T cells from treated and untreated mice could not be differentiated anymore, suggesting that T cells largely regained their original status. In sum, the biological information obtained from Raman spectra agrees with immunological readouts demonstrating that Raman spectroscopy is a well-suited, label-free method for following splenic T cell activation in systemic inflammation from acute to postacute phases. The method can also be applied to directly study tissue sections as is demonstrated for spleen tissue one day after LPS insult.T lymphocytes (T cells) are highly specialized members of the adaptive immune system and hold the key to the understanding the hosts’ response toward invading pathogen or pathogen-associated molecular patterns such as LPS. In this study, noninvasive Raman spectroscopy is presented as a label-free method to follow LPS-induced changes in splenic T cells during acute and postacute inflammatory phases (1, 4, 10, and 30 d) with a special focus on CD4+ and CD8+ T cells of endotoxemic C57BL/6 mice. Raman spectral analysis reveals highest chemical differences between CD4+ and CD8+ T cells originating from the control and LPS-treated mice during acute inflammation, and the differences are visible up to 10 d after the LPS insult. In the postacute phase, CD4+ and CD8+ T cells from treated and untreated mice could not be differentiated anymore, suggesting that T cells largely regained their original status. In sum, the biological information obtained from Raman spectra agrees with immunological readouts demonstrating that Raman spectroscopy is a well-suited, label-free method for following splenic T cell activation in systemic inflammation from acute to postacute phases. The method can also be applied to directly study tissue sections as is demonstrated for spleen tissue one day after LPS insult.
  • Item
    Beer's Law-Why Integrated Absorbance Depends Linearly on Concentration
    (Weinheim : Wiley-VCH Verl., 2019) Mayerhöfer, Thomas G.; Pipa, Andrei V.; Popp, Jürgen
    As derived by Max Planck in 1903 from dispersion theory, Beer's law has a fundamental limitation. The concentration dependence of absorbance can deviate from linearity, even in the absence of any interactions or instrumental nonlinearities. Integrated absorbance, not peak absorbance, depends linearly on concentration. The numerical integration of the absorbance leads to maximum deviations from linearity of less than 0.1 %. This deviation is a consequence of a sum rule that was derived from the Kramers-Kronig relations at a time when the fundamental limitation of Beer's law was no longer mentioned in the literature. This sum rule also links concentration to (classical) oscillator strengths and thereby enables the use of dispersion analysis to determine the concentration directly from transmittance and reflectance measurements. Thus, concentration analysis of complex samples, such as layered and/or anisotropic materials, in which Beer's law cannot be applied, can be achieved using dispersion analysis. ©2019 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.