Search Results

Now showing 1 - 2 of 2
  • Item
    Improved accuracy in high-frequency AC transport measurements in pulsed high magnetic fields
    ([S.l.] : American Institute of Physics, 2020) Mitamura, Hiroyuki; Watanuki, Ryuta; Kampert, Erik; Förster, Tobias; Matsuo, Akira; Onimaru, Takahiro; Onozaki, Norimichi; Amou, Yuta; Wakiya, Kazuhei; Yamamoto, Isao; Matsumoto, Keisuke T.; Suzuki, Kazuya; Zherlitsyn, Sergei; Wosnitza, Joachim; Tokunaga, Masashi; Kindo, Koichi; Sakakibara, Toshiro
    We show theoretically and experimentally that accurate transport measurements are possible even within the short time provided by pulsed magnetic fields. For this purpose, a new method has been devised, which removes the noise component of a specific frequency from the signal by taking a linear combination of the results of numerical phase detection using multiple integer periods. We also established a method to unambiguously determine the phase rotation angle in AC transport measurements using a frequency range of tens of kilohertz. We revealed that the dominant noise in low-frequency transport measurements in pulsed magnetic fields is the electromagnetic induction caused by mechanical vibrations of wire loops in inhomogeneous magnetic fields. These results strongly suggest that accurate transport measurements in short-pulsed magnets are possible when mechanical vibrations are well suppressed. © 2020 Author(s).
  • Item
    Piezoelectric-driven uniaxial pressure cell for muon spin relaxation and neutron scattering experiments
    ([S.l.] : American Institute of Physics, 2020) Ghosh, Shreenanda; Brückner, Felix; Nikitin, Artem; Grinenko, Vadim; Elender, Matthias; Mackenzie, Andrew P.; Luetkens, Hubertus; Klauss, Hans-Henning; Hicks, Clifford W.
    We present a piezoelectric-driven uniaxial pressure cell that is optimized for muon spin relaxation and neutron scattering experiments and that is operable over a wide temperature range including cryogenic temperatures. To accommodate the large samples required for these measurement techniques, the cell is designed to generate forces up to ∼1000 N. To minimize the background signal, the space around the sample is kept as open as possible. We demonstrate here that by mounting plate-like samples with epoxy, a uniaxial stress exceeding 1 GPa can be achieved in an active volume of at least 5 mm3. We show that for practical operation, it is important to monitor both the force and displacement applied to the sample. In addition, because time is critical during facility experiments, samples are mounted in detachable holders that can be rapidly exchanged. The piezoelectric actuators are likewise contained in an exchangeable cartridge. © 2020 Author(s).