    A customizable microfluidic platform for medium-throughput modeling of neuromuscular circuits
    (Amsterdam [u.a.] : Elsevier Science, 2019) Bellmann, Jessica; Goswami, Ruchi Y.; Girardo, Salvatore; Rein, Nelly; Hosseinzadeh, Zohreh; Hicks, Michael R.; Busskamp, Volker; Pyle, April D.; Werner, Carsten; Sterneckert, Jared
    Neuromuscular circuits (NMCs) are vital for voluntary movement, and effective models of NMCs are needed to understand the pathogenesis of, as well as to identify effective treatments for, multiple diseases, including Duchenne's muscular dystrophy and amyotrophic lateral sclerosis. Microfluidics are ideal for recapitulating the central and peripheral compartments of NMCs, but myotubes often detach before functional NMCs are formed. In addition, microfluidic systems are often limited to a single experimental unit, which significantly limits their application in disease modeling and drug discovery. Here, we developed a microfluidic platform (MFP) containing over 100 experimental units, making it suitable for medium-throughput applications. To overcome detachment, we incorporated a reactive polymer surface allowing customization of the environment to culture different cell types. Using this approach, we identified conditions that enable long-term co-culture of human motor neurons and myotubes differentiated from human induced pluripotent stem cells inside our MFP. Optogenetics demonstrated the formation of functional NMCs. Furthermore, we developed a novel application of the rabies tracing assay to efficiently identify NMCs in our MFP. Therefore, our MFP enables large-scale generation and quantification of functional NMCs for disease modeling and pharmacological drug targeting. © 2019 The Authors
  • Item
    A new method to measure real-world respiratory tract deposition of inhaled ambient black carbon
    (Amsterdam [u.a.] : Elsevier Science, 2019) Madueño, Leizel; Kecorius, Simonas; Löndahl, Jakob; Müller, Thomas; Pfeifer, Sascha; Haudek, Andrea; Mardoñez, Valeria; Wiedensohler, Alfred
    In this study, we present the development of a mobile system to measure real-world total respiratory tract deposition of inhaled ambient black carbon (BC). Such information can be used to supplement the existing knowledge on air pollution-related health effects, especially in the regions where the use of standard methods and intricate instrumentation is limited. The study is divided in two parts. Firstly, we present the design of portable system and methodology to evaluate the exhaled air BC content. We demonstrate that under real-world conditions, the proposed system exhibit negligible particle losses, and can additionally be used to determine the minute ventilation. Secondly, exemplary experimental data from the system is presented. A feasibility study was conducted in the city of La Paz, Bolivia. In a pilot experiment, we found that the cumulative total respiratory tract deposition dose over 1-h commuting trip would result in approximately 2.6 μg of BC. This is up to 5 times lower than the values obtained from conjectural approach (e.g. using physical parameters from previously reported worksheets). Measured total respiratory tract deposited BC fraction varied from 39% to 48% during walking and commuting inside a micro-bus, respectively. To the best of our knowledge, no studies focusing on experimental determination of real-world deposition dose of BC have been performed in developing regions. This can be especially important because the BC mass concentration is significant and determines a large fraction of particle mass concentration. In this work, we propose a potential method, recommendations, as well as the limitations in establishing an easy and relatively cheap way to estimate the respiratory tract deposition of BC. In this study we present a novel method to measure real-world respiratory tract deposition dose of Black Carbon. Results from a pilot study in La Paz, Bolivia, are presented. © 2019 The Authors
  • Item
    A novel multidrug-resistant PVL-negative CC1-MRSA-IV clone emerging in Ireland and Germany likely originated in South-Eastern Europe
    (Amsterdam [u.a.] : Elsevier Science, 2019) Earls, Megan R.; Shore, Anna C.; Brennan, Gráinne I.; Simbeck, Alexandra; Schneider-Brachert, Wulf; Vremerǎ, Teodora; Dorneanu, Olivia S.; Slickers, Peter; Ehricht, Ralf; Monecke, Stefan; Coleman, David C.
    This study investigated the recent emergence of multidrug-resistant Panton-Valentine leukocidin (PVL)-negative CC1-MRSA-IV in Ireland and Germany. Ten CC1-MSSA and 139 CC1-MRSA isolates recovered in Ireland between 2004 and 2017 were investigated. These were compared to 21 German CC1-MRSA, 10 Romanian CC1-MSSA, five Romanian CC1-MRSA and two UAE CC1-MRSA, which were selected from an extensive global database, based on similar DNA microarray profiles to the Irish isolates. All isolates subsequently underwent whole-genome sequencing, core-genome single nucleotide polymorphism (cgSNP) analysis and enhanced SCCmec subtyping. Two PVL-negative clades (A and B1) were identified among four main clades. Clade A included 20 German isolates, 119 Irish isolates, and all Romanian MRSA and MSSA isolates, the latter of which differed from clade A MRSA by 47–130 cgSNPs. Eighty-six Irish clade A isolates formed a tight subclade (A1) exhibiting 0–49 pairwise cgSNPs, 80 of which harboured a 46 kb conjugative plasmid carrying both ileS2, encoding high-level mupirocin resistance, and qacA, encoding chlorhexidine resistance. The resistance genes aadE, aphA3 and sat were detected in all clade A MRSA and the majority (8/10) of clade A MSSA isolates. None of the clade A isolates harboured any enterotoxin genes other than seh, which is universally present in CC1. Clade B1 included the remaining German isolate, 17 Irish isolates and the two UAE isolates, all of which corresponded to the Western Australia MRSA-1 (WA MRSA-1) clone based on genotypic characteristics. MRSA within clades A and B1 differed by 188 cgSNPs and clade-specific SCCmec characteristics were identified, indicating independent acquisition of the SCCmec element. This study demonstrated the existence of a European PVL-negative CC1-MRSA-IV clone that is distinctly different from the well-defined PVL-negative CC1-MRSA-IV clone, WA MRSA-1. Furthermore, cgSNP analysis revealed that this newly defined clone may have originated in South-Eastern Europe, before spreading to both Ireland and Germany. © 2019 The Authors
  • Item
    Available and missing data to model impact of climate change on European forests
    (Amsterdam [u.a.] : Elsevier Science, 2019) Ruiz-Benito, Paloma; Vacchiano, Giorgio; Lines, Emily R.; Reyer, Christopher P.O.; Ratcliffe, Sophia; Morin, Xavier; Hartig, Florian; Mäkelä, Annikki; Yousefpour, Rasoul; Chaves, Jimena E.; Palacios-Orueta, Alicia; Benito-Garzón, Marta; Morales-Molino, Cesar; Camarero, J. Julio; Jump, Alistair S.; Kattge, Jens; Lehtonen, Aleksi; Ibrom, Andreas; Owen, Harry J.F.; Zavala, Miguel A.
    Climate change is expected to cause major changes in forest ecosystems during the 21st century and beyond. To assess forest impacts from climate change, the existing empirical information must be structured, harmonised and assimilated into a form suitable to develop and test state-of-the-art forest and ecosystem models. The combination of empirical data collected at large spatial and long temporal scales with suitable modelling approaches is key to understand forest dynamics under climate change. To facilitate data and model integration, we identified major climate change impacts observed on European forest functioning and summarised the data available for monitoring and predicting such impacts. Our analysis of c. 120 forest-related databases (including information from remote sensing, vegetation inventories, dendroecology, palaeoecology, eddy-flux sites, common garden experiments and genetic techniques) and 50 databases of environmental drivers highlights a substantial degree of data availability and accessibility. However, some critical variables relevant to predicting European forest responses to climate change are only available at relatively short time frames (up to 10-20 years), including intra-specific trait variability, defoliation patterns, tree mortality and recruitment. Moreover, we identified data gaps or lack of data integration particularly in variables related to local adaptation and phenotypic plasticity, dispersal capabilities and physiological responses. Overall, we conclude that forest data availability across Europe is improving, but further efforts are needed to integrate, harmonise and interpret this data (i.e. making data useable for non-experts). Continuation of existing monitoring and networks schemes together with the establishments of new networks to address data gaps is crucial to rigorously predict climate change impacts on European forests. © 2019 The Author(s)
  • Item
    Discovery of hemocompatible bacterial biofilm-resistant copolymers
    (Amsterdam [u.a.] : Elsevier Science, 2020) Singh, Taranjit; Hook, Andrew L.; Luckett, Jeni; Maitz, Manfred F.; Sperling, Claudia; Werner, Carsten; Davies, Martyn C.; Irvine, Derek J.; Williams, Paul; Alexander, R.
    Blood-contacting medical devices play an important role within healthcare and are required to be biocompatible, hemocompatible and resistant to microbial colonization. Here we describe a high throughput screen for copolymers with these specific properties. A series of weakly amphiphilic monomers are combinatorially polymerized with acrylate glycol monomers of varying chain lengths to create a library of 645 multi-functional candidate materials containing multiple chemical moieties that impart anti-biofilm, hemo- and immuno-compatible properties. These materials are screened in over 15,000 individual biological assays, targeting two bacterial species, one Gram negative (Pseudomonas aeruginosa) and one Gram positive (Staphylococcus aureus) commonly associated with central venous catheter infections, using 5 different measures of hemocompatibility and 6 measures of immunocompatibililty. Selected copolymers reduce platelet activation, platelet loss and leukocyte activation compared with the standard comparator PTFE as well as reducing bacterial biofilm formation in vitro by more than 82% compared with silicone. Poly(isobornyl acrylate-co-triethylene glycol methacrylate) (75:25) is identified as the optimal material across all these measures reducing P. aeruginosa biofilm formation by up to 86% in vivo in a murine foreign body infection model compared with uncoated silicone. © 2020 The Authors
  • Item
    Cylindrospermopsin is effectively degraded in water by pulsed corona-like and dielectric barrier discharges
    (Amsterdam [u.a.] : Elsevier Science, 2020) Schneider, Marcel; Rataj, Raphael; Kolb, Juergen F.; Bláha, Luděk
    Cylindrospermopsin (CYN) is an important cyanobacterial toxin posing a major threat to surface waters during cyanobacterial blooms. Hence, methods for cyanotoxin removal are required to confront seasonal or local incidences to sustain the safety of potable water reservoirs. Non-thermal plasmas provide the possibility for an environmentally benign treatment which can be adapted to specific concentrations and environmental conditions without the need of additional chemicals. We therefore investigated the potential of two different non-thermal plasma approaches for CYN degradation, operated either in a water mist, i.e. in air, or submerged in water. A degradation efficacy of 0.03 ± 0.00 g kWh−1 L−1 was found for a dielectric barrier discharge (DBD) operated in air, while a submerged pulsed corona-like discharge resulted in an efficacy of 0.24 ± 0.02 g kWh−1 L−1. CYN degradation followed a pseudo zeroth order or pseudo first order reaction kinetic, respectively. Treatment efficacy of the corona-like discharge submerged in water increased with pH values of the initial solution changing from 5.0 to 7.5. Notably, a pH-depending residual oxidative effect was observed for the submerged discharge, resulting in ongoing CYN degradation, even without further plasma treatment. In this case hydroxyl radicals were identified as the dominant oxidants of CYN at acidic pH values. In comparison, degradation by the DBD could be related primarily to the generation of ozone. © 2020 The AuthorsThe degradation of cylindrospermopsin by a pulsed corona-like discharge in water was more effective compared with a pulsed dielectric barrier discharge in air around a water mist. © 2020 The Authors
  • Item
    Validation study for measuring absorption and reduced scattering coefficients by means of laser-induced backscattering imaging
    (Amsterdam [u.a.] : Elsevier Science, 2019) Zude-Sasse, Manuela; Hashim, Norhashila; Hass, Roland; Polley, Nabarun; Regen, Christian
    Decoupling of optical properties appears challenging, but vital to get better insight of the relationship between light and fruit attributes. In this study, nine solid phantoms capturing the ranges of absorption (μa) and reduced scattering (μs’) coefficients in fruit were analysed non-destructively using laser-induced backscattering imaging (LLBI) at 1060 nm. Data analysis of LLBI was carried out on the diffuse reflectance, attenuation profile obtained by means of Farrell's diffusion theory either calculating μa [cm−1] and μs’ [cm−1] in one fitting step or fitting only one optical variable and providing the other one from a destructive analysis. The nondestructive approach was approved when calculating one unknown coefficient non-destructively, while no ability of the method was found to analysis both, μa and μs’, non-destructively. Setting μs’ according to destructive photon density wave (PDW) spectroscopy and fitting μa resulted in root mean square error (rmse) of 18.7% in comparison to fitting μs’ resulting in rmse of 2.6%, pointing to decreased measuring uncertainty, when the highly variable μa was known. The approach was tested on European pear, utilizing destructive PDW spectroscopy for setting one variable, while LLBI was applied for calculating the remaining coefficient. Results indicated that the optical properties of pear obtained from PDW spectroscopy as well as LLBI changed concurrently in correspondence to water content mainly. A destructive batch-wise analysis of μs’ and online analysis of μa may be considered in future developments for improved fruit sorting results, when considering fruit with high variability of μs’. © 2019 The Authors
  • Item
    Visible-NIR ‘point’ spectroscopy in postharvest fruit and vegetable assessment: The science behind three decades of commercial use
    (Amsterdam [u.a.] : Elsevier Science, 2020) Walsh, Kerry B.; Blasco, José; Zude-Sasse, Manuela; Sun, Xudong
    The application of visible (Vis; 400–750 nm) and near infrared red (NIR; 750–2500 nm) region spectroscopy to assess fruit and vegetables is reviewed in context of ‘point’ spectroscopy, as opposed to multi- or hyperspectral imaging. Vis spectroscopy targets colour assessment and pigment analysis, while NIR spectroscopy has been applied to assessment of macro constituents (principally water) in fresh produce in commercial practice, and a wide range of attributes in the scientific literature. This review focusses to key issues relevant to the widespread implementation of Vis-NIR technology in the fruit sector. A background to the concepts and technology involved in the use of Vis-NIR spectroscopy is provided and instrumentation for in-field and in-line applications, which has been available for two and three decades, respectively, is described. A review of scientific effort is made for the period 2015 - February 2020, in terms of the application areas, instrumentation, chemometric methods and validation procedures, and this work is critiqued through comparison to techniques in commercial use, with focus to wavelength region, optical geometry, experimental design, and validation procedures. Recommendations for future research activity in this area are made, e.g., application development with consideration of the distribution of the attribute of interest in the product and the matching of optically sampled and reference method sampled volume; instrumentation comparisons with consideration of repeatability, optimum optical geometry and wavelength range). Recommendations are also made for reporting requirements, viz. description of the application, the reference method, the composition of calibration and test populations, chemometric reporting and benchmarking to a known instrument/method, with the aim of maximising useful conclusions from the extensive work being done around the world.