Search Results

Now showing 1 - 10 of 19
  • Item
    Terahertz quantum-cascade lasers for high-resolution absorption spectroscopy of atoms and ions in plasmas
    (Bristol : IOP Publ., 2023) Lü, X.; Röben, B.; Biermann, K.; Wubs, J.R.; Macherius, U.; Weltmann, K.-D.; van Helden, J.H.; Schrottke, L.; Grahn, H.T.
    We report on terahertz (THz) quantum-cascade lasers (QCLs) based on GaAs/AlAs heterostructures, which exhibit single-mode emission at 3.360, 3.921, and 4.745 THz. These frequencies are in close correspondence to fine-structure transitions of Al atoms, N+ ions, and O atoms, respectively. Due to the low electrical pump power of these THz QCLs, they can be operated in a mechanical cryocooler in continuous-wave mode, while a sufficient intrinsic tuning range of more than 5 GHz is maintained. The single-mode operation and the intrinsic tuning range of these THz QCLs allow for the application of these lasers as radiation sources for high-resolution absorption spectroscopy to determine the absolute densities of Al atoms, N+ ions, and O atoms in plasmas.
  • Item
    Ecological and functional optimization of the pretreatment process for plasma based coatings of cutting tools
    (2019) Uhlmann, E.; Riemer, H.; An, S.; Fröhlich, M.; Paschke, H.; Petersen, M.
    Increasing demands in machining of high-tech materials and dry machining lead to higher thermal and mechanical loads on cutting tools. In response to these challenges, enhanced coating solutions are applied to increase performance and life of cutting tools. However, during the production process the cemented carbide substrates are contaminated with grinding oils and residues of organic material. For the subsequent physical vapor deposition (PVD) coating process an intensive and high-quality cleaning process is necessary. In this contribution, plasma electrolytic polishing (PEP) is used as a novel alternative to conventional ecologically harmful cleaning baths. Apart from the ecological advantage, the surface of the substrate can be optimized with regard to the coating adhesion. To examine the performance of the different cleaning processes, machining tests were performed at the IWF to evaluate the layer adhesion and tool life of the tools.
  • Item
    Cathode fall voltage of TIG arcs from a non-equilibrium arc model
    (Heidelberg : Springer, 2014) Uhrlandt, D.; Baeva, M.; Pipa, A.V.; Kozakov, R.; Gött, G.
    This work presents modelling results concerning a tungsten inert gas (TIG) welding arc. The model provides a consistent description of the free burning arc, the arc attachment and the electrodes. Thermal and chemical non-equilibrium is considered in the whole arc area, and a detailed model of the cathode space-charge sheath is included. The mechanisms in the cathode pre-sheath are treated in the framework of a non-equilibrium approach which is based on a two-fluid description of electrons and heavy particles and a simplified plasma chemistry of argon. A consistent determination of the electrode fall voltages and temperature distributions is achieved. The model is applied to arcs in pure argon at currents up to 250 A, whereby welding of a workpiece made of mild steel with a fixed burner is considered. Arc voltages in the range from 12 to 17 V are obtained at 50 at 250 A, respectively. The space-charge sheath voltage is found to be about 7 V and almost independent of the current. The corresponding temperatures of the cathode tip are in the range from 3,000 K to about 3,800 K. The results obtained are in a good agreement with measurements.
  • Item
    Thermal protection implementation of the contact overheadline based on bay controllers of electric transport traction substations in the mining industry
    (Sankt-Peterburg : Inst., 2021) Lantsev, Dmitry; Frolov, Vladimir; Zverev, Sergej; Uhrlandt, Dirk; Valenta, Jiří
    The article presents the principle of thermal protection of the contact overheadlineand substantiates the possibility of practical implementation of this principle for rail electric transport in the mining industry. The algorithm for the implementation of modern digital protection of the contact overhead line as one of the functions of the controller is described. A mathematical model of thermal protection is proposed, which follows from the solution of the heat balance equation. The model takes into account the coefficient of the electrical networktopology, as well as the coefficient of consumption of the current-carrying core of the cable, which determines the reduction in the conducting section from contact erosion and the growth of oxide films. Corrections for air flows are introduced when receiving data from an external anemometer, via telemechanics protocol. The mathematical model was tested by writing a real thermal protection program in the C programming language for the bay controller, based on the circuitry of which is the STM32F407IGT6 microcontroller for the microcontroller unit. Verification tests were carried out on a serial bay controller in 2020. The graphs for comparing the calculated and actual values of temperatures, with different flow rates of the current-carrying conductor of the DC cable, are given. To obtain data, telemechanics protocols IEC 60870-104 and Modbus TCP, PLC Segnetics SMH4 were used.
  • Item
    Interaction of a free burning arc with regenerative protective layers
    (Bristol : Institute of Physics Publishing, 2014) Uhrlandt, D.; Gorchakov, S.; Brueser, V.; Franke, S.; Khakpour, A.; Lisnyak, M.; Methling, R.; Schoenemann, T.
    The possible use of protective layers made of ceramic powders for walls in thermal plasma applications is studied. A stable free burning arc of currents up to 5 kA between copper- tungsten electrodes is used to analyse the arc interaction with samples coated by mixtures of CaCO3, MgCO3, and Mg(OH)2 with plaster. By means of optical emission spectroscopy the maximum arc temperature and the radiation impact on the surfaces are estimated to be around 15000 K and 20 MWm-2, respectively. Thermographic measurements confirm the efficient protection of substrates by all layer materials. Layers containing CaCO3 lead to the lowest heating of ceramic samples which may be caused by a strong evaporation of the layer material.
  • Item
    Atmospheric pressure plasma: A high-performance tool for the efficient removal of biofilms
    (San Francisco, CA : Public Library of Science, 2012) Fricke, K.; Koban, I.; Tresp, H.; Jablonowski, L.; Schröder, K.; Kramer, A.; Weltmann, K.-D.; von Woedtke, T.; Kocher, T.
    Introduction: The medical use of non-thermal physical plasmas is intensively investigated for sterilization and surface modification of biomedical materials. A further promising application is the removal or etching of organic substances, e.g., biofilms, from surfaces, because remnants of biofilms after conventional cleaning procedures are capable to entertain inflammatory processes in the adjacent tissues. In general, contamination of surfaces by micro-organisms is a major source of problems in health care. Especially biofilms are the most common type of microbial growth in the human body and therefore, the complete removal of pathogens is mandatory for the prevention of inflammatory infiltrate. Physical plasmas offer a huge potential to inactivate micro-organisms and to remove organic materials through plasma-generated highly reactive agents. Method: In this study a Candida albicans biofilm, formed on polystyrene (PS) wafers, as a prototypic biofilm was used to verify the etching capability of the atmospheric pressure plasma jet operating with two different process gases (argon and argon/oxygen mixture). The capability of plasma-assisted biofilm removal was assessed by microscopic imaging. Results: The Candida albicans biofilm, with a thickness of 10 to 20 μm, was removed within 300 s plasma treatment when oxygen was added to the argon gas discharge, whereas argon plasma alone was practically not sufficient in biofilm removal. The impact of plasma etching on biofilms is localized due to the limited presence of reactive plasma species validated by optical emission spectroscopy.
  • Item
    Optimizing the application of plasma functionalised water (PFW) for microbial safety in fresh-cut endive processing
    (New York, NY [u.a.] : Elsevier Science, 2021) Schnabel, Uta; Balazinski, Martina; Wagner, Robert; Stachowiak, Jörg; Boehm, Daniela; Andrasch, Mathias; Bourke, Paula; Ehlbeck, Jörg
    The microbiological profiles and responses of native microflora of endive were investigated using a model process line, to establish where a defined PFW should be optimally applied to retain or improve produce microbiological quality. The PFW processes were compared with tap water and ClO2. The antimicrobial efficacy of PFW was quantified by determining the reduction in microbial load, the microbial viability and vitality. Depending on the stage of application of PFW, up to 5 log10-cycles reduction was achieved, accompanied by a reduction of metabolic activity, but not necessarily with a decrease in metabolic vitality. Multiple application (3-step-PFW-application) was more effective than single application (1-step-PFW-application) and PFW showed stronger antimicrobial effect in pre-cleaned endive. High concentrations of nitrite (315 mg l−1) and nitrate (472 mg l−1) in PFW were the main factors for the antimicrobial efficacy of PFW against bacteria. Furthermore, H2O2 and an acidic pH supported the mechanism of action against the endive microflora. These results identify the pathway to scale up successful industrial application of PFW targeting microbiological quality and safety of fresh leafy products.Industrial relevance The safety, quality and shelf life of freshly cut vegetables, e.g. lettuce, are strongly influenced by the microbial load. In addition, the hygienic design of production line, and a good handling/ production practice are indispensable. This study shows that the application of PFW, as a promising non-thermal sanitation technology, enables the inactivation of native microbial contamination on fresh-cut endive depending on the process stage of application. It further describes the impact of PFW on the metabolic activity and metabolic vitality of the lettuce-associated microflora. For higher acceptance, the mechanism of action of PFW was assumed based on previous chemical analyses and compared to the industrial standard of ClO2. The results contribute to the understanding and product-specificity of PFW-induced effects on safety, quality and shelf life of fresh cut lettuce and could be a basis for a possible industrial implementation and complement of common technologies.
  • Item
    Development of an electrochemical sensor for in-situ monitoring of reactive species produced by cold physical plasma
    (Amsterdam [u.a.] : Elsevier Science, 2021) Nasri, Zahra; Bruno, Giuliana; Bekeschus, Sander; Weltmann, Klaus-Dieter; von Woedtke, Thomas; Wende, Kristian
    The extent of clinical applications of oxidative stress-based therapies such as photodynamic therapy (PDT) or respiratory chain disruptors are increasing rapidly, with cold physical plasma (CPP) emerging as a further option. According to the current knowledge, the biological effects of CPP base on reactive oxygen and nitrogen species (RONS) relevant in cell signaling. To monitor the safety and the biological impact of the CPP, determining the local generation of RONS in the same environment in which they are going to be applied is desirable. Here, for the first time, the development of an electrochemical sensor for the simple, quick, and parallel determination of plasma-generated reactive species is described. The proposed sensor consists of a toluidine blue redox system that is covalently attached to a gold electrode surface. By recording chronoamperometry at different potentials, it is possible to follow the in-situ production of the main long-lived reactive oxygen and nitrogen species like hydrogen peroxide, nitrite, hypochlorite, and chloramine with time. The applicability of this electrochemical sensor for the in-situ assessment of reactive species in redox-based therapies is demonstrated by the precise analysis of hydrogen peroxide dynamics in the presence of blood cancer cells.
  • Item
    Terahertz quantum-cascade lasers for high-resolution absorption spectroscopy of atoms and ions in plasmas
    (Bristol : IOP Publ., 2023) Lü, X.; Röben, B.; Biermann, K.; Wubs, J.R.; Macherius, U.; Weltmann, K.-D.; van Helden, J.H.; Schrottke, L.; Grahn, H.T.
    We report on terahertz (THz) quantum-cascade lasers (QCLs) based on GaAs/AlAs heterostructures, which exhibit single-mode emission at 3.360, 3.921, and 4.745 THz. These frequencies are in close correspondence to fine-structure transitions of Al atoms, N+ ions, and O atoms, respectively. Due to the low electrical pump power of these THz QCLs, they can be operated in a mechanical cryocooler in continuous-wave mode, while a sufficient intrinsic tuning range of more than 5 GHz is maintained. The single-mode operation and the intrinsic tuning range of these THz QCLs allow for the application of these lasers as radiation sources for high-resolution absorption spectroscopy to determine the absolute densities of Al atoms, N+ ions, and O atoms in plasmas.
  • Item
    RES-Q-Trace: A Mobile CEAS-Based Demonstrator for Multi-Component Trace Gas Detection in the MIR
    (Basel : MDPI, 2018-6-27) Lang, Norbert; Macherius, Uwe; Zimmermann, Henrik; Glitsch, Sven; Wiese, Mathias; Röpcke, Jürgen; van Helden, Jean-Pierre H.
    Sensitive trace gas detection plays an important role in current challenges occurring in areas such as industrial process control and environmental monitoring. In particular, for medical breath analysis and for the detection of illegal substances, e.g., drugs and explosives, a selective and sensitive detection of trace gases in real-time is required. We report on a compact and transportable multi-component system (RES-Q-Trace) for molecular trace gas detection based on cavity-enhanced techniques in the mid-infrared (MIR). The RES-Q-Trace system can operate four independent continuous wave quantum or interband cascade lasers each combined with an optical cavity. Twice the method of off-axis cavity-enhanced absorption spectroscopy (OA-CEAS) was used, twice the method of optical feedback cavity-enhanced absorption spectroscopy (OF-CEAS), respectively. Multi-functional software has been implemented (i) for the general system control; (ii) to drive the four different laser sources and (iii) to analyze the detector signals for concentration determination of several molecular species. For the validation of the versatility and the performance of the RES-Q-Trace instrument the species NO, N2O, CH4, C2H4 and C3H6O, with relevance in the fields of breath gas analysis and the detection of explosives have been monitored in the MIR with detection limits at atmospheric pressure in the ppb and ppt range.