Search Results

Now showing 1 - 10 of 92
  • Item
    Strain Engineered Electrically Pumped SiGeSn Microring Lasers on Si
    (Washington, DC : ACS, 2022) Marzban, Bahareh; Seidel, Lukas; Liu, Teren; Wu, Kui; Kiyek, Vivien; Zoellner, Marvin Hartwig; Ikonic, Zoran; Schulze, Joerg; Grützmacher, Detlev; Capellini, Giovanni; Oehme, Michael; Witzens, Jeremy; Buca, Dan
    SiGeSn holds great promise for enabling fully group-IV integrated photonics operating at wavelengths extending in the mid-infrared range. Here, we demonstrate an electrically pumped GeSn microring laser based on SiGeSn/GeSn heterostructures. The ring shape allows for enhanced strain relaxation, leading to enhanced optical properties, and better guiding of the carriers into the optically active region. We have engineered a partial undercut of the ring to further promote strain relaxation while maintaining adequate heat sinking. Lasing is measured up to 90 K, with a 75 K T0. Scaling of the threshold current density as the inverse of the outer circumference is linked to optical losses at the etched surface, limiting device performance. Modeling is consistent with experiments across the range of explored inner and outer radii. These results will guide additional device optimization, aiming at improving electrical injection and using stressors to increase the bandgap directness of the active material.
  • Item
    RES-Q-Trace: A Mobile CEAS-Based Demonstrator for Multi-Component Trace Gas Detection in the MIR
    (Basel : MDPI, 2018-6-27) Lang, Norbert; Macherius, Uwe; Zimmermann, Henrik; Glitsch, Sven; Wiese, Mathias; Röpcke, Jürgen; van Helden, Jean-Pierre H.
    Sensitive trace gas detection plays an important role in current challenges occurring in areas such as industrial process control and environmental monitoring. In particular, for medical breath analysis and for the detection of illegal substances, e.g., drugs and explosives, a selective and sensitive detection of trace gases in real-time is required. We report on a compact and transportable multi-component system (RES-Q-Trace) for molecular trace gas detection based on cavity-enhanced techniques in the mid-infrared (MIR). The RES-Q-Trace system can operate four independent continuous wave quantum or interband cascade lasers each combined with an optical cavity. Twice the method of off-axis cavity-enhanced absorption spectroscopy (OA-CEAS) was used, twice the method of optical feedback cavity-enhanced absorption spectroscopy (OF-CEAS), respectively. Multi-functional software has been implemented (i) for the general system control; (ii) to drive the four different laser sources and (iii) to analyze the detector signals for concentration determination of several molecular species. For the validation of the versatility and the performance of the RES-Q-Trace instrument the species NO, N2O, CH4, C2H4 and C3H6O, with relevance in the fields of breath gas analysis and the detection of explosives have been monitored in the MIR with detection limits at atmospheric pressure in the ppb and ppt range.
  • Item
    Growth of PdCoO2 films with controlled termination by molecular-beam epitaxy and determination of their electronic structure by angle-resolved photoemission spectroscopy
    (Melville, NY : AIP Publ., 2022) Song, Qi; Sun, Jiaxin; Parzyck, Christopher T.; Miao, Ludi; Xu, Qing; Hensling, Felix V. E.; Barone, Matthew R.; Hu, Cheng; Kim, Jinkwon; Faeth, Brendan D.; Paik, Hanjong; King, Phil D. C.; Shen, Kyle M.; Schlom, Darrell G.
    Utilizing the powerful combination of molecular-beam epitaxy (MBE) and angle-resolved photoemission spectroscopy (ARPES), we produce and study the effect of different terminating layers on the electronic structure of the metallic delafossite PdCoO2. Attempts to introduce unpaired electrons and synthesize new antiferromagnetic metals akin to the isostructural compound PdCrO2 have been made by replacing cobalt with iron in PdCoO2 films grown by MBE. Using ARPES, we observe similar bulk bands in these PdCoO2 films with Pd-, CoO2-, and FeO2-termination. Nevertheless, Pd- and CoO2-terminated films show a reduced intensity of surface states. Additionally, we are able to epitaxially stabilize PdFexCo1-xO2 films that show an anomaly in the derivative of the electrical resistance with respect to temperature at 20 K, but do not display pronounced magnetic order.
  • Item
    Electrically-Pumped Wavelength-Tunable GaAs Quantum Dots Interfaced with Rubidium Atoms
    (Washington, DC : ACS, 2017) Huang, Huiying; Trotta, Rinaldo; Huo, Yongheng; Lettner, Thomas; Wildmann, Johannes S.; Martín-Sánchez, Javier; Huber, Daniel; Reindl, Marcus; Zhang, Jiaxiang; Zallo, Eugenio; Schmidt, Oliver G.; Rastelli, Armando
    We demonstrate the first wavelength-tunable electrically pumped source of nonclassical light that can emit photons with wavelength in resonance with the D2 transitions of 87Rb atoms. The device is fabricated by integrating a novel GaAs single-quantum-dot light-emitting diode (LED) onto a piezoelectric actuator. By feeding the emitted photons into a 75 mm long cell containing warm 87Rb vapor, we observe slow-light with a temporal delay of up to 3.4 ns. In view of the possibility of using 87Rb atomic vapors as quantum memories, this work makes an important step toward the realization of hybrid-quantum systems for future quantum networks.
  • Item
    Lasing by Template-Assisted Self-Assembled Quantum Dots
    (Weinheim : Wiley-VCH, 2023) Aftenieva, Olha; Sudzius, Markas; Prudnikau, Anatol; Adnan, Mohammad; Sarkar, Swagato; Lesnyak, Vladimir; Leo, Karl; Fery, Andreas; König, Tobias A.F.
    Miniaturized laser sources with low threshold power are required for integrated photonic devices. Photostable core/shell nanocrystals are well suited as gain material and their laser properties can be exploited by direct patterning as distributed feedback (DFB) lasers. Here, the 2nd-order DFB resonators tuned to the photoluminescence wavelength of the QDs are used. Soft lithography based on template-assisted colloidal self-assembly enables pattern resolution in the subwavelength range. Combined with the directional Langmuir–Blodgett arrangement, control of the waveguide layer thickness is further achieved. It is shown that a lasing threshold of 5.5 mJ cm−2 is reached by a direct printing method, which can be further reduced by a factor of ten (0.6 mJ cm−2) at an optimal waveguide thickness. Moreover, it is discussed how one can adjust the DFB geometries to any working wavelength. This colloidal approach offers prospects for applications in bioimaging, biomedical sensing, anti-counterfeiting, or displays.
  • Item
    Development of a Mobile Sensory Device to Trace Treatment Conditions for Various Medical Plasma Source Devices
    (Basel : MDPI, 2022) Chaerony Siffa, Ihda; Gerling, Torsten; Masur, Kai; Eschenburg, Christian; Starkowski, Frank; Emmert, Steffen
    The emerging use of low-temperature plasma in medicine, especially in wound treatment, calls for a better way of documenting the treatment parameters. This paper describes the development of a mobile sensory device (referred to as MSD) that can be used during the treatment to ease the documentation of important parameters in a streamlined process. These parameters include the patient’s general information, plasma source device used in the treatment, plasma treatment time, ambient humidity and temperature. MSD was developed as a standalone Raspberry Pi-based version and attachable module version for laptops and tablets. Both versions feature a user-friendly GUI, temperature–humidity sensor, microphone, treatment report generation and export. For the logging of plasma treatment time, a sound-based plasma detection system was developed, initially for three medically certified plasma source devices: kINPen® MED, plasma care®, and PlasmaDerm® Flex. Experimental validation of the developed detection system shows accurate and reliable detection is achievable at 5 cm measurement distance in quiet and noisy environments for all devices. All in all, the developed tool is a first step to a more automated, integrated, and streamlined approach of plasma treatment documentation that can help prevent user variability.
  • Item
    Experiments on MEMS Integration in 0.25 μm CMOS Process
    (Basel : MDPI, 2018) Michalik, Piotr; Fernández, Daniel; Wietstruck, Matthias; Kaynak, Mehmet; Madrenas, Jordi
    In this paper, we share our practical experience gained during the development of CMOS-MEMS (Complementary Metal-Oxide Semiconductor Micro Electro Mechanical Systems) devices in IHP SG25 technology. The experimental prototyping process is illustrated with examples of three CMOS-MEMS chips and starts from rough process exploration and characterization, followed by the definition of the useful MEMS design space to finally reach CMOS-MEMS devices with inertial mass up to 4.3 μg and resonance frequency down to 4.35 kHz. Furthermore, the presented design techniques help to avoid several structural and reliability issues such as layer delamination, device stiction, passivation fracture or device cracking due to stress.
  • Item
    Local Structure Investigation of Cu Precipitates in Modified 18CrNiMo7-6 Steels by Synchrotron X-ray Absorption Spectroscopy
    (Tōkyō : ISIJ, 2022) Suwanpinij, Piyada; Bambach, Margarita; Bootchanont, Atipong; Sailuam, Wutthigrai
    This paper studied the copper precipitation in an 18CrNiMo7-6 martensitic steel (0.19 mass% C) with copper addition and its resulting improved mechanical behavior. The development of nano-precipitates in two modified alloys with 1.0 and 1.5 mass% copper addition was investigated by means of synchrotron X-ray absorption spectroscopy. The first-principles calculation has enabled the modeling of the unavailable copper standards: solid solution, B2, BCC, 2H, 9R and 3R, for calculating the XAS spectra and successfully identified the unknown phases after aging for the first time in this steel group. The samples alloyed with 1.5 mass% copper yielded the semi-coherent 9R structure when aged at 500°C between 166 to 360 minutes. The ones containing 1 mass% copper formed the B2 ordered structure after aging at 480°C for 50 minutes and revealed the co-existence of the 9R after 240 minutes. The analysis reveals the precipitation kinetics of copper in low carbon martensitic steel and helps determine the optimum tempering parameters to adjust peak strength.
  • Item
    Terahertz quantum-cascade lasers for high-resolution absorption spectroscopy of atoms and ions in plasmas
    (Bristol : IOP Publ., 2023) Lü, X.; Röben, B.; Biermann, K.; Wubs, J.R.; Macherius, U.; Weltmann, K.-D.; van Helden, J.H.; Schrottke, L.; Grahn, H.T.
    We report on terahertz (THz) quantum-cascade lasers (QCLs) based on GaAs/AlAs heterostructures, which exhibit single-mode emission at 3.360, 3.921, and 4.745 THz. These frequencies are in close correspondence to fine-structure transitions of Al atoms, N+ ions, and O atoms, respectively. Due to the low electrical pump power of these THz QCLs, they can be operated in a mechanical cryocooler in continuous-wave mode, while a sufficient intrinsic tuning range of more than 5 GHz is maintained. The single-mode operation and the intrinsic tuning range of these THz QCLs allow for the application of these lasers as radiation sources for high-resolution absorption spectroscopy to determine the absolute densities of Al atoms, N+ ions, and O atoms in plasmas.
  • Item
    Applications of Electronic Nose, Electronic Eye and Electronic Tongue in Quality, Safety and Shelf Life of Meat and Meat Products: A Review
    (Basel : MDPI, 2023) Munekata, Paulo E. S.; Finardi, Sarah; de Souza, Carolina Krebs; Meinert, Caroline; Pateiro, Mirian; Hoffmann, Tuany Gabriela; Domínguez, Rubén; Bertoli, Sávio Leandro; Kumar, Manoj; Lorenzo, José M.
    The quality and shelf life of meat and meat products are key factors that are usually evaluated by complex and laborious protocols and intricate sensory methods. Devices with attractive characteristics (fast reading, portability, and relatively low operational costs) that facilitate the measurement of meat and meat products characteristics are of great value. This review aims to provide an overview of the fundamentals of electronic nose (E-nose), eye (E-eye), and tongue (E-tongue), data preprocessing, chemometrics, the application in the evaluation of quality and shelf life of meat and meat products, and advantages and disadvantages related to these electronic systems. E-nose is the most versatile technology among all three electronic systems and comprises applications to distinguish the application of different preservation methods (chilling vs. frozen, for instance), processing conditions (especially temperature and time), detect adulteration (meat from different species), and the monitoring of shelf life. Emerging applications include the detection of pathogenic microorganisms using E-nose. E-tongue is another relevant technology to determine adulteration, processing conditions, and to monitor shelf life. Finally, E-eye has been providing accurate measuring of color evaluation and grade marbling levels in fresh meat. However, advances are necessary to obtain information that are more related to industrial conditions. Advances to include industrial scenarios (cut sorting in continuous processing, for instance) are of great value.