Search Results

Now showing 1 - 6 of 6
Loading...
Thumbnail Image
Item

Sub-15-fs X-ray pump and X-ray probe experiment for the study of ultrafast magnetization dynamics in ferromagnetic alloys

2021, Liu, Xuan, Merhe, Alaaeldine, Jal, Emmanuelle, Delaunay, Renaud, Jarrier, Romain, Chardonnet, Valentin, Hennes, Marcel, Chiuzbaian, Sorin G., Légaré, Katherine, Hennecke, Martin, Radu, Ilie, Von Korff Schmising, Clemens, Grunewald, Særen, Kuhlmann, Marion, Lüning, Jan, Vodungbo, Boris

In this paper, we present a new setup for the measurement of element-specific ultrafast magnetization dynamics in ferromagnetic thin films with a sub-15-fs time resolution. Our experiment relies on a split and delay approach which allows us to fully exploit the shortest X-rays pulses delivered by X-ray Free Electrons Lasers (close to the attosecond range), in an X-ray pump – X-ray probe geometry. The setup performance is demonstrated by measuring the ultrafast elemental response of Ni and Fe during demagnetization of ferromagnetic Ni and Ni80Fe20 (Permalloy) samples upon resonant excitation at the corresponding absorption edges. The transient demagnetization process is measured in both reflection and transmission geometry using, respectively, the transverse magneto-optical Kerr effect (T-MOKE) and the Faraday effect as probing mechanisms.

Loading...
Thumbnail Image
Item

Increasing the performance of a superconducting spin valve using a Heusler alloy

2018, Kamashev, A.A., Validov, A.A., Schumann, J., Kataev, V., Büchner, B., Fominov, Y.V., Garifullin, I.A.

We have studied superconducting properties of spin-valve thin-layer heterostructures CoOx/F1/Cu/F2/Cu/Pb in which the ferromagnetic F1 layer was made of Permalloy while for the F2 layer we have taken a specially prepared film of the Heusler alloy Co2Cr1-xFexAl with a small degree of spin polarization of the conduction band. The heterostructures demonstrate a significant superconducting spin-valve effect, i.e., a complete switching on and offof the superconducting current flowing through the system by manipulating the mutual orientations of the magnetization of the F1 and F2 layers. The magnitude of the effect is doubled in comparison with the previously studied analogous multilayers with the F2 layer made of the strong ferromagnet Fe. Theoretical analysis shows that a drastic enhancement of the switching effect is due to a smaller exchange field in the heterostructure coming from the Heusler film as compared to Fe. This enables to approach an almost ideal theoretical magnitude of the switching in the Heusler-based multilayer with a F2 layer thickness of ca. 1 nm. © 2018 Kamashev et al.

Loading...
Thumbnail Image
Item

Electrodeposition of Fe70Pd30 nanowires from a complexed ammonium-sulfosalicylic electrolyte with high stability

2010, Haehnel, V., Fähler, S., Schultz, L., Schlörb, H.

A highly stable plating bath for the electrodeposition of Fe-Pd nanowires into nanoporous alumina templates has been developed. Complexing of both metal ions and exchanging Fe2+ by Fe3+ avoid chemical reduction of Pd ions and, therefore, undesirable deposition. By using a pulse potential mode and appropriate adjustment of deposition potentials homogeneously filled templates without surface deposits and nanowires close to the desired composition of Fe70Pd30 have been achieved. These alloy nanowires represent a key step towards nanoactuators based on magnetic shape memory alloys. © 2010 Elsevier B.V. All rights reserved.

Loading...
Thumbnail Image
Item

Superconducting switching due to a triplet component in the Pb/Cu/Ni/Cu/Co2Cr1-xFexAly spin-valve structure

2019, Kamashev, A.A., Garif'yanov, N.N., Validov, A.A., Schumann, J., Kataev, V., Büchner, B., Fominov, Y.V., Garifullin, I.A.

We report the superconducting properties of the Co2Cr1-xFexAly/Cu/Ni/Cu/Pb spin-valve structure the magnetic part of which comprises the Heusler alloy layer HA = Co2Cr1-xFexAly with a high degree of spin polarization (DSP) of the conduction band and a Ni layer of variable thickness. The separation between the superconducting transition curves measured for the parallel (α = 0°) and perpendicular (α = 90°) orientation of the magnetization of the HA and the Ni layers reaches up to 0.5 K (α is the angle between the magnetization of two ferromagnetic layers). For all studied samples the dependence of the superconducting transition temperature Tc on α demonstrates a deep minimum in the vicinity of the perpendicular configuration of the magnetizations. This suggests that the observed minimum and the corresponding full switching effect of the spin valve is caused by the long-range triplet component of the superconducting condensate in the multilayer. Such a large effect can be attributed to a half-metallic nature of the HA layer, which in the orthogonal configuration efficiently draws off the spin-polarized Cooper pairs from the space between the HA and Ni layers. Our results indicate a significant potential of the concept of a superconducting spin-valve multilayer comprising a half-metallic ferromagnet, recently proposed by A. Singh et al., Phys. Rev. X 2015, 5, 021019, in achieving large values of the switching effect.

Loading...
Thumbnail Image
Item

Single-crystalline FeCo nanoparticle-filled carbon nanotubes: Synthesis, structural characterization and magnetic properties

2018, Ghunaim, R., Scholz, M., Damm, C., Rellinghaus, B., Klingeler, R., Büchner, B., Mertig, M., Hampel, S.

In the present work, we demonstrate different synthesis procedures for filling carbon nanotubes (CNTs) with equimolar binary nanoparticles of the type Fe-Co. The CNTs act as templates for the encapsulation of magnetic nanoparticles and provide a protective shield against oxidation as well as prevent nanoparticle agglomeration. By variation of the reaction parameters, we were able to tailor the sample purity, degree of filling, the composition and size of the filling particles, and therefore, the magnetic properties. The samples were analyzed by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), superconducting quantum interference device (SQUID) and thermogravimetric analysis (TGA). The Fe-Co-filled CNTs show significant enhancement in the coercive field as compared to the corresponding bulk material, which make them excellent candidates for several applications such as magnetic storage devices.

Loading...
Thumbnail Image
Item

Magnetically induced anisotropy of flux penetration into strong-pinning superconductor/ferromagnet bilayers

2019, Simmendinger, J., Hanisch, J., Bihler, M., Ionescu, A.M., Weigand, M., Sieger, M., Hühne, R., Rijckaert, H., Van Driessche, I., Schütz, G., Albrecht, J.

We studied the impact of soft ferromagnetic permalloy (Py) on the shielding currents in a strong-pinning superconductor - YBa2Cu3O7-δ with Ba2Y(Nb/Ta)O6 nano-precipitates - by means of scanning transmission x-ray microscopy. Typically and in particular when in the thin film limit, superconductor/ferromagnet (SC/FM) bilayers exhibit isotropic properties of the flux line ensemble at all temperatures. However, in elements with small aspect ratio a significant anisotropy in flux penetration is observed. We explain this effect by local in-plane fields arising from anisotropic magnetic stray fields originated by the ferromagnet. This leads to direction-dependent motion of magnetic vortices inside the SC/FM bilayer. Our results demonstrate that small variations of the magnetic properties can have huge impact on the superconductor.