Search Results

Now showing 1 - 9 of 9
  • Item
    Investigation of horizontal structures at mesospheric altitudes using coherent radar imaging
    (Göttingen : Copernicus, 2013) Sommer, S.; Stober, G.; Schult, C.; Zecha, M.; Latteck, R.
    The Middle Atmosphere Alomar Radar System (MAARSY) in Northern Norway (69.30°N, 16.04°E) was used to perform interferometric observations of Polar Mesosperic Summer Echoes (PMSE) in June 2012. Coherent Radar Imaging (CRI) using Capon's method was applied allowing a high spatial resolution. The algorithm was validated by simulation and trajectories of meteor head echoes. Both data sets show a good correspondence with the algorithm. Using this algorithm, the aspect sensitivity of PMSE was analysed in a case study, making use of the capability of CRI to resolve the pattern within the beam volume. No correction of the beam pattern was made yet. It was found in this case study, that no large variations in the scattering width and the scattering center occured apart from a very short period of time at the upper edge of the PMSE.
  • Item
    Photoelectron holography in strong optical and dc electric fields
    (Bristol : Institute of Physics Publishing, 2014) Stodolna, A.; Huismans, Y.; Rouzée, A.; Lépine, F.; Vrakking, M.J.J.
    The application of velocity map imaging for the detection of photoelectrons resulting from atomic or molecular ionization allows the observation of interferometric, and in some cases holographic structures that contain detailed information on the target from which the photoelecrons are extracted. In this contribution we present three recent examples of the use of photoelectron velocity map imaging in experiments where atoms are exposed to strong optical and dc electric fields. We discuss (i) observations of the nodal structure of Stark states of hydrogen measured in a dc electric field, (ii) mid-infrared strong-field ionization of metastable Xe atoms and (iii) the reconstruction of helium electronic wavepackets in an attosecond pump-probe experiment. In each case, the interference between direct and indirect electron pathways, reminiscent of the reference and signal waves in holography, is seen to play an important role.
  • Item
    Side-view holographic endomicroscopy via a custom-terminated multimode fibre
    (Washington, DC : Soc., 2021) Silveira, Beatriz M.; Pikálek, Tomáš; Stibůrek, Miroslav; Ondráčková, Petra; Jákl, Petr; Leite, Ivo T.; Čižmár, Tomáš
    Microendoscopes based on optical fibres have recently come to the fore as promising candidates allowing in-vivo observations of otherwise inaccessible biological structures in animal models. Despite being still in its infancy, imaging can now be performed at the tip of a single multimode fibre, by relying on powerful holographic methods for light control. Fibre based endoscopy is commonly performed en face, resulting in possible damage of the specimen owing to the direct contact between the distal end of the probe and target. On this ground, we designed an all-fibre probe with an engineered termination that reduces compression and damage to the tissue under investigation upon probe insertion. The geometry of the termination brings the field of view to a plane parallel to the fibre’s longitudinal direction, conveying the probe with off-axis imaging capabilities. We show that its focusing ability also benefits from a higher numerical aperture, resulting in imaging with increased spatial resolution. The effect of probe insertion was investigated inside a tissue phantom comprising fluorescent particles suspended in agarose gel, and a comparison was established between the novel side-view probe and the standard en face fibre probe. This new concept paves the way to significantly less invasive deep-tissue imaging.
  • Item
    Reference shape effects on Fourier transform holography
    (Washington, DC : Soc., 2022) Malm, Erik; Pfau, Bastian; Schneider, Michael; Günther, Christian M.; Hessing, Piet; Büttner, Felix; Mikkelsen, Anders; Eisebitt, Stefan
    Soft-x-ray holography which utilizes an optics mask fabricated in direct contact with the sample, is a widely applied x-ray microscopy method, in particular, for investigating magnetic samples. The optics mask splits the x-ray beam into a reference wave and a wave to illuminate the sample. The reconstruction quality in such a Fourier-transform holography experiment depends primarily on the characteristics of the reference wave, typically emerging from a small, high-aspect-ratio pinhole in the mask. In this paper, we study two commonly used reference geometries and investigate how their 3D structure affects the reconstruction within an x-ray Fourier holography experiment. Insight into these effects is obtained by imaging the exit waves from reference pinholes via high-resolution coherent diffraction imaging combined with three-dimensional multislice simulations of the x-ray propagation through the reference pinhole. The results were used to simulate Fourier-transform holography experiments to determine the spatial resolution and precise location of the reconstruction plane for different reference geometries. Based on our findings, we discuss the properties of the reference pinholes with view on application in soft-x-ray holography experiments.
  • Item
    Autocorrected off-axis holography of two-dimensional materials
    (College Park, ML : American Physical Society, 2020) Kern, Felix; Linck, Martin; Wolf, Daniel; Alem, Nasim; Arora, Himani; Gemming, Sibylle; Erbe, Artur; Zettl, Alex; Büchner, Bernd; Lubk, Axel
    The reduced dimensionality in two-dimensional materials leads to a wealth of unusual properties, which are currently explored for both fundamental and applied sciences. In order to study the crystal structure, edge states, the formation of defects and grain boundaries, or the impact of adsorbates, high-resolution microscopy techniques are indispensable. Here we report on the development of an electron holography (EH) transmission electron microscopy (TEM) technique, which facilitates high spatial resolution by an automatic correction of geometric aberrations. Distinguished features of EH beyond conventional TEM imaging are gap-free spatial information signal transfer and higher dose efficiency for certain spatial frequency bands as well as direct access to the projected electrostatic potential of the two-dimensional material. We demonstrate these features with the example of h-BN, for which we measure the electrostatic potential as a function of layer number down to the monolayer limit and obtain evidence for a systematic increase of the potential at the zig-zag edges.
  • Item
    Observing distant objects with a multimode fiber-based holographic endoscope
    (Melville, NY : AIP Publishing, 2021) Leite, Ivo T.; Turtaev, Sergey; Boonzajer Flaes, Dirk E.; Čižmár, Tomáš
    Holographic wavefront manipulation enables converting hair-thin multimode optical fibers into minimally invasive lensless imaging instruments conveying much higher information densities than conventional endoscopes. Their most prominent applications focus on accessing delicate environments, including deep brain compartments, and recording micrometer-scale resolution images of structures in close proximity to the distal end of the instrument. Here, we introduce an alternative "far-field"endoscope capable of imaging macroscopic objects across a large depth of field. The endoscope shaft with dimensions of 0.2 × 0.4 mm2 consists of two parallel optical fibers: one for illumination and the other for signal collection. The system is optimized for speed, power efficiency, and signal quality, taking into account specific features of light transport through step-index multimode fibers. The characteristics of imaging quality are studied at distances between 20 mm and 400 mm. As a proof-of-concept, we provide imaging inside the cavities of a sweet pepper commonly used as a phantom for biomedically relevant conditions. Furthermore, we test the performance on a functioning mechanical clock, thus verifying its applicability in dynamically changing environments. With the performance reaching the standard definition of video endoscopes, this work paves the way toward the exploitation of minimally invasive holographic micro-endoscopes in clinical and diagnostics applications. © 2021 Author(s).
  • Item
    Microparticle Manipulation and Imaging through a Self-Calibrated Liquid Crystal on Silicon Display
    (Basel : MDPI, 2018-11-20) Zhang, Haolin; Lizana, Angel; Van Eeckhout, Albert; Turpin, Alex; Ramirez, Claudio; Iemmi, Claudio; Campos, Juan
    We present in this paper a revision of three different methods we conceived in the framework of liquid crystal on silicon (LCoS) display optimization and application. We preliminarily demonstrate an LCoS self-calibration technique, from which we can perform a complete LCoS characterization. In particular, two important characteristics of LCoS displays are retrieved by using self-addressed digital holograms. On the one hand, we determine its phase-voltage curve by using the interference pattern generated by a digital two-sectorial split-lens configuration. On the other hand, the LCoS surface profile is also determined by using a self-addressed dynamic micro-lens array pattern. Second, the implementation of microparticle manipulation through optical traps created by an LCoS display is demonstrated. Finally, an LCoS display based inline (IL) holographic imaging system is described. By using the LCoS display to implement a double-sideband filter configuration, this inline architecture demonstrates the advantage of obtaining dynamic holographic imaging of microparticles independently of their spatial positions by avoiding the non-desired conjugate images.
  • Item
    Holographic vector field electron tomography of three-dimensional nanomagnets
    (London : Nature Publishing Group, 2019) Wolf, D.; Biziere, N.; Sturm, S.; Reyes, D.; Wade, T.; Niermann, T.; Krehl, J.; Warot-Fonrose, B.; Büchner, B.; Snoeck, E.; Gatel, C.; Lubk, A.
    Complex 3D magnetic textures in nanomagnets exhibit rich physical properties, e.g., in their dynamic interaction with external fields and currents, and play an increasing role for current technological challenges such as energy-efficient memory devices. To study these magnetic nanostructures including their dependency on geometry, composition, and crystallinity, a 3D characterization of the magnetic field with nanometer spatial resolution is indispensable. Here we show how holographic vector field electron tomography can reconstruct all three components of magnetic induction as well as the electrostatic potential of a Co/Cu nanowire with sub 10 nm spatial resolution. We address the workflow from acquisition, via image alignment to holographic and tomographic reconstruction. Combining the obtained tomographic data with micromagnetic considerations, we derive local key magnetic characteristics, such as magnetization current or exchange stiffness, and demonstrate how magnetization configurations, such as vortex states in the Co-disks, depend on small structural variations of the as-grown nanowire.
  • Item
    Achieving diffraction-limited resolution in soft-X-ray Fourier-transform holography
    (Amsterdam : Elsevier Science, 2020) Geilhufe, Jan; Pfau, Bastian; Günther, Christian M.; Schneider, Michael; Eisebitt, Stefan
    The spatial resolution of microscopic images acquired via X-ray Fourier-transform holography is limited by the source size of the reference wave and by the numerical aperture of the detector. We analyze the interplay between both influences and show how they are matched in practice. We further identify, how high spatial frequencies translate to imaging artifacts in holographic reconstructions where mainly the reference beam limits the spatial resolution. As a solution, three methods are introduced based on numerical post-processing of the reconstruction. The methods comprise apodization of the hologram, refocusing via wave propagation, and deconvolution using the transfer function of the imaging system. In particular for the latter two, we demonstrate that image details smaller than the source size of the reference beam can be recovered up to the diffraction limit of the hologram. Our findings motivate the intentional application of a large reference-wave source enhancing the image contrast in applications with low photon numbers such as single-shot experiments at free-electron lasers or imaging at laboratory sources.