Search Results

Now showing 1 - 4 of 4
  • Item
    Very low ozone episodes due to polar vortex displacement
    (Milton Park : Taylor & Francis, 2000) James, P.M.; Peters, D.; Waugh, D.W.
    The large-scale ozone distribution over the northern hemisphere undergoes strong fluctuationseach winter on timescales of up to a few weeks. This is closely linked to changes in the stratosphericpolar vortex, whose shape, intensity and location vary with time. Elliptical diagnosticparameters provide an empirical description of the daily character of the polar vortex. Theseparameters are used as an objective measure to define two characteristic wintertime vortexdisplacements, towards northern Europe and Canada, respectively. The large-scale structuresin both the stratosphere and troposphere and the 3D ozone structures are determined for bothvortex displacement scenarios. A linear ozone transport model shows that the contribution ofhorizontal ozone advection dominates locally in the middle stratosphere. Nevertheless, thelargest contribution is due to vertical advection around the ozone layer maximum. The findingsare in agreement with an EOF analysis which reveals significant general modes of ozone variabilitylinked to polar vortex displacement and to phase-shifted large-scale tropospheric waves.When baroclinic waves travel through the regions of vortex-related ozone reduction, the combinedeffect is to produce transient synoptic-scale areas of exceptionally low ozone; namelydynamically induced strong ozone mini-holes.
  • Item
    Long-term lidar observations of polar stratospheric clouds at Esrange in northern Sweden
    (Milton Park : Taylor & Francis, 2005) Blum, U.; Fricke, K.H.; Müller, K.P.; Siebert, J.; Baumgarten, G.
    Polar stratospheric clouds (PSCs) play a key role in the depletion of polar ozone. The type of cloud and the length of time for which it exists are crucial for the amount of chlorine activation during the polar night. The Bonn University backscatter lidar at Esrange in northern Sweden (68◦N, 21◦E) is well equipped for long-term observation and classification of these clouds. Nearly continuous measurements through several winters are rare, in particular in wave-active regions like Esrange. Lidar measurements have been performed each winter since 1997—a total of more than 2000 h of observation time has been accumulated, including more than 300 h with PSCs. Analysis of this unique data set leads to a classification scheme with four different scattering characteristics which can be associated with four different cloud types: (1) supercooled ternary solution (STS), (2) nitric acid trihydrate (NAT), (3) ice and (4) mixtures of solid and liquid particles. The analysis of observations over seven winters gives an overview of the frequency of appearance of the individual PSC types. Most of the clouds contain layers of different PSC types. The analysis of these layers shows STS and mixed clouds to occur most frequently, with more than 39% and 37% of all PSC observations, respectively, whereas NAT (15%) and ice clouds (9%) are seen only rarely. The lidar is located close to the Scandinavian mountain ridge, which is a major source of orographically induced gravity waves that can rapidly cool the atmosphere below cloud formation temperatures. Comparing the individual existence temperature of the observed cloud type with the synoptic-scale temperature provided by the European Centre for Medium-range Weather Forecasts (ECMWF) gives information on the frequency of synoptically and wave-induced PSCs. Further, the analysis of ECMWF temperature and wind data gives an estimate of the transparency of the atmosphere to stationary gravity waves. During more than 80% of all PSC observations in synoptic-scale temperatures which were too warm the atmosphere was transparent for stationary gravity waves. Our measurements show that dynamically induced cooling is crucial for the existence of PSCs above Esrange. In particular ice PSCs are observed only in situations where there are gravity waves.
  • Item
    Nonequilibrium phase transitions in finite arrays of globally coupled Stratonovich models: Strong coupling limit
    (College Park, MD : Institute of Physics Publishing, 2009) Senf, F.; Altrock, P.M.; Behn, U.
    A finite array of N globally coupled Stratonovich models exhibits a continuous nonequilibrium phase transition. In the limit of strong coupling, there is a clear separation of timescales of centre of mass and relative coordinates. The latter relax very fast to zero and the array behaves as a single entity described by the centre of mass coordinate. We compute analytically the stationary probability distribution and the moments of the centre of mass coordinate. The scaling behaviour of the moments near the critical value of the control parameter ac(N) is determined. We identify a crossover from linear to square root scaling with increasing distance from ac. The crossover point approaches ac in the limit N →∞ which reproduces previous results for infinite arrays. Our results are obtained in both the Fokker-Planck and the Langevin approach and are corroborated by numerical simulations. For a general class of models we show that the transition manifold in the parameter space depends on N and is determined by the scaling behaviour near a fixed point of the stochastic flow. © IOP Publishing Ltd and Deutsche Physikalische Gesellschaft.
  • Item
    Upper stratospheric ozone decrease events due to a positive feedback between ozone and the ozone dissociation rate
    (Göttingen : Copernicus, 2009) Sonnemann, G.R.; Hartogh, P.
    Ozone measurements taken with a ground based microwave instrument at Lindau (51.66° N, 10.13° E) over some years showed strong ozone decrease events within the stratopause region, particularly during the winter half-year. These events are characterized by a marked drop of the ozone mixing ratio from two to three ppmv to less than half a ppmv in extreme cases. Simultaneous water vapor measurements at the same place, also carried out by a microwave instrument, showed a strong increase of its mixing ratio and the temperature was also enhanced during these episodes. The theoretical analysis brought evidence that these events result from a positive feedback in the complex radiatively-chemical system between the ozone column density and the ozone dissociation rate.