Search Results

Now showing 1 - 10 of 45
  • Item
    Application of the transferred matrix method to a unified evaluation of the cathodic electron emission
    (New York, NY : American Inst. of Physics, 2018) Baeva, M.
    The work is concerned with the Transfer Matrix Method for solving the steady-state Schrödinger equation applied for a unified evaluation of the emission current density from non-refractory cathodes. The method is applicable to arbitrary shapes of the potential barrier and its transmission probability is obtained without any analytical approximations. The Fermi-Dirac distribution for the free electrons in the metal is considered as a supply function. The results, obtained for a work function of the cathode material of 4.5 eV over a wide range of values of the surface temperature and the electric field strength, clearly show a growing deviation from those obtained by the classical Jeffreys-Wentzel-Kramers-Brillouin approximation with the increase of the electric field strength. Preliminary results are obtained to demonstrate the applicability of the Transfer Matrix method to the evaluation of the ion-assisted electron emission. A significant local enhancement of the emission current density is obtained as a result of the presence of an ion at a fixed position near the metal surface. The effect becomes very strongly pronounced at an appropriate value of the electric field strength, for which a resonant ion contribution appears.
  • Item
    The equivalent circuit approach for the electrical diagnostics of dielectric barrier discharges: The classical theory and recent developments
    (Basel : MDPI AG, 2019) Pipa, Andrei V.; Brandenburg, Ronny
    Measurements of current and voltage are the basic diagnostics for electrical discharges. However, in the case of dielectric barrier discharges (DBDs), the measured current and voltage waveforms are influenced by the discharge reactor geometry, and thus, interpretation of measured quantities is required to determine the discharge properties. This contribution presents the main stages of the development of electrical diagnostics of DBDs, which are based on lumped electrical elements. The compilation and revision of the contributions to the equivalent circuit approach are targeted to indicate: (1) the interconnection between the stage of development, (2) its applicability, and (3) the current state-of-the-art of this approach. © 2019 by the authors.
  • Item
    Enhanced reliability of drift-diffusion approximation for electrons in fluid models for nonthermal plasmas
    (New York, NY : American Inst. of Physics, 2013) Becker, M.M.; Loffhagen, D.
    Common fluid models used for the description of electron transport in nonthermal discharge plasmas are subject to substantial restrictions if the electron energy transport significantly influences the discharge behaviour. A drift-diffusion approach is presented which is based on a multiterm approximation of the electron velocity distribution function and overcomes some of these restrictions. It is validated using a benchmark model and applied for the analysis of argon discharge plasmas at low and atmospheric pressure. The results are compared to those of common drift-diffusion models as well as to experimental data. It is pointed out that fluid models are able to describe nonlocal phenomena caused by electron energy transport, if the energy transport is consistently described. Numerical difficulties that frequently occur when the conventional drift-diffusion model is consistently applied are avoided by the proposed method.
  • Item
    Phase-resolved measurement of electric charge deposited by an atmospheric pressure plasma jet on a dielectric surface
    (Bristol : Institute of Physics Publishing, 2014) Wild, R.; Gerling, T.; Bussiahn, R.; Weltmann, K.-D.; Stollenwerk, L.
    The surface charge distribution deposited by the effluent of a dielectric barrier discharge driven atmospheric pressure plasma jet on a dielectric surface has been studied. For the first time, the deposition of charge was observed phase resolved. It takes place in either one or two events in each half cycle of the driving voltage. The charge transfer could also be detected in the electrode current of the jet. The periodic change of surface charge polarity has been found to correspond well with the appearance of ionized channels left behind by guided streamers (bullets) that have been identified in similar experimental situations. The distribution of negative surface charge turned out to be significantly broader than for positive charge. With increasing distance of the jet nozzle from the target surface, the charge transfer decreases until finally the effluent loses contact and the charge transfer stops.
  • Item
    Optical diagnostics of streamers: From laboratory micro-scale to upper-atmospheric large-scale discharges
    (Bristol : Institute of Physics Publishing, 2014) Simek, M.; Hoder, T.; Prukner, V.; Ambrico, P.F.
    Optical emission produced by streamers is determined by spatial distribution of electronically excited atomic and diatomic species within the streamer head and streamer channel. Peculiarities of emission and LIF diagnostics dedicated to investigating the basic structure of streamers with high spatio-temporal resolution are discussed. Possible strategies based on the 2D projections of cylindrically symmetric streamers to determine radial distributions of excited species within the streamer channel are illustrated for streamers produced in volume or on the dielectric surface at atmospheric and low pressures.
  • Item
    Corrigendum: Dielectric barrier discharges: progress on plasma sources and on the understanding of regimes and single filaments (Plasma Sources Science and Technology (2017) 26 (053001) DOI: 10.1088/1361-6595/aa6426)
    (Bristol : IOP Publ., 2018) Brandenburg, Ronny
    The paper Dielectric barrier discharges: progress on plasma sources and on the understanding of regimes and single filaments? [1] contains a serious misprint in the section ?Electrical behavior and characterization?. The correct equation (5) for the determination of the gap voltage Ug is as follows (Formula Presented). The second term is the voltage across the barrier (Ub) which is determined by the charge Q t and the capacity of the barrier(s) Cd. The parameter 1 Ccell as written in the original paper is not correct, and a misprint. The sum of gap voltage and barrier voltage equals the applied voltage V t . Detailed explanations about the formula can be found in the cited literature, in particular [2-4].
  • Item
    Stability and excitation dynamics of an argon micro-scaled atmospheric pressure plasma jet
    (Bristol : IOP Publ., 2015) Dünnbier, M.; Becker, M.M.; Iseni, S.; Bansemer, R.; Loffhagen, D.; Reuter, S.; Weltmann, K.-D.
    A megahertz-driven plasma jet at atmospheric pressure—the so-called micro-scaled atmospheric pressure plasma jet (μAPPJ)—operating in pure argon has been investigated experimentally and by numerical modelling. To ignite the discharge in argon within the jet geometry, a self-made plasma tuning unit was designed, which additionally enables measurements of the dissipated power in the plasma itself. Discharges in the α-mode up to their transition to the γ-mode were studied experimentally for varying frequencies. It was found that the voltage at the α–γ transition behaves inversely proportional to the applied frequency f and that the corresponding power scales with an f  3/2law. Both these findings agree well with the results of time-dependent, spatially one-dimensional fluid modelling of the discharge behaviour, where the f  3/2 scaling of the α–γ transition power is additionally verified by the established concept of a critical plasma density for sheath breakdown. Furthermore, phase resolved spectroscopy of the optical emission at 750.39 nm as well as at 810.37 nm and 811.53 nm was applied to analyse the excitation dynamics of the discharge at 27 MHz for different applied powers. The increase of the power leads to an additional maximum in the excitation structure of the 750.39 nm line emission at the α–γ transition point, whereas the emission structure around 811 nm does not change qualitatively. According to the fluid modelling results, this differing behaviour originates from the different population mechanisms of the corresponding energy levels of argon.
  • Item
    Advanced fluid modeling and PIC/MCC simulations of low-pressure ccrf discharges
    (Bristol : IOP Publ., 2017-3-2) Becker, M.M.; Kählert, H.; Sun, A.; Bonitz, M.; Loffhagen, D.
    Comparative studies of capacitively coupled radio-frequency discharges in helium and argon at pressures between 10 and 80 Pa are presented applying two different fluid modeling approaches as well as two independently developed particle-in-cell/Monte Carlo collision (PIC/MCC) codes. The focus is on the analysis of the range of applicability of a recently proposed fluid model including an improved drift-diffusion approximation for the electron component as well as its comparison with fluid modeling results using the classical drift-diffusion approximation and benchmark results obtained by PIC/MCC simulations. Main features of this time- and space-dependent fluid model are given. It is found that the novel approach shows generally quite good agreement with the macroscopic properties derived by the kinetic simulations and is largely able to characterize qualitatively and quantitatively the discharge behavior even at conditions when the classical fluid modeling approach fails. Furthermore, the excellent agreement between the two PIC/MCC simulation codes using the velocity Verlet method for the integration of the equations of motion verifies their accuracy and applicability.
  • Item
    Impact of plasma jet vacuum ultraviolet radiation on reactive oxygen species generation in bio-relevant liquids
    ([S.l.] : American Institute of Physics, 2015) Jablonowski, H.; Bussiahn, R.; Hammer, M.U.; Weltmann, K.-D.; von Woedtke, T.; Reuter, S.
    Plasma medicine utilizes the combined interaction of plasma produced reactive components. These are reactive atoms, molecules, ions, metastable species, and radiation. Here, ultraviolet (UV, 100–400 nm) and, in particular, vacuum ultraviolet (VUV, 10–200 nm) radiation generated by an atmospheric pressure argon plasma jet were investigated regarding plasma emission, absorption in a humidified atmosphere and in solutions relevant for plasma medicine. The energy absorption was obtained for simple solutions like distilled water (dH2O) or ultrapure water and sodium chloride (NaCl) solution as well as for more complex ones, for example, Rosewell Park Memorial Institute (RPMI 1640) cell culture media. As moderate stable reactive oxygen species, hydrogen peroxide (H2O2) was studied. Highly reactive oxygen radicals, namely, superoxide anion (O2•−) and hydroxyl radicals (•OH), were investigated by the use of electron paramagnetic resonance spectroscopy. All species amounts were detected for three different treatment cases: Plasma jet generated VUV and UV radiation, plasma jet generated UV radiation without VUV part, and complete plasma jet including all reactive components additionally to VUV and UV radiation. It was found that a considerable amount of radicals are generated by the plasma generated photoemission. From the experiments, estimation on the low hazard potential of plasma generated VUV radiation is discussed.
  • Item
    Emission Spectroscopy During High-Current Anode Modes in Vacuum Arc
    (Praha : Czech Technical University in Prague, Faculty of Electrical Engineering, Department of Physics, 2017) Khakpour, A.; Methling, R.; Franke, S.; Gortschakow, S.; Uhrlandt, D.
    A vacuum interrupter reaches its interruption limit once high-current anode phenomena occur. High-current anode modes lead to an increase of the anode surface temperature and an increased generation of metal vapor, which may result in a weakening of the dielectric recovery strength after current zero. In this work, different discharge modes in a vacuum arc for AC 50 Hz including diffuse, footpoint, anode spot type 1 and type 2, and anode plume are investigated. Electrodes made of CuCr7525 with diameter of 10 mm are used. The final gap length is about 20 mm. Time and space resolved optical emission spectroscopy is used to examine the temporal and spatial distribution of atomic and ionic copper lines. The distribution of atomic and ionic lines parallel and perpendicular to the anode surface is investigated. Radiator density is also determined for CuI, CuII, and CuIII near the anode surface.