Search Results

Now showing 1 - 10 of 21
  • Item
    Two-Step-Model of Photosensitivity in Cerium-doped Fibers
    (Washington D.C. : Optical Society of America, 2019) Elsmann, Tino; Becker, Martin; Olusoji, Olugbenga; Unger, Sonja; Wondraczek, Katrin; Aichele, Claudia; Lindner, Florian; Schwuchow, Anka; Nold, Johannes; Rothhardt, Manfred
    The photosensitivity of various cerium-doped fibers has been experimentally investigated for both excimer- and femtosecond-laser illumination. The results of single-pulse, few-pulse and multi-pulse inscription of fiber-Bragg-gratings with both laser systems and the thermal aging of those gratings demonstrated the restrictions of the conventional color center model for cerium-doped fibers. To explain the short-term stability of single-pulse gratings against long-term stability of multi-pulse gratings, an extension into a two-step-model was deduced.
  • Item
    Label-free CARS microscopy through a multimode fibre endoscope
    (Washington D.C. : Optical Society of America, 2019) Trägårdh, Johanna; Pikálek, Tomáš; Šerý, Mojmír; Meyer, Tobias; Popp, Jürgen; Čižmár, Tomáš
    Multimode fibres have recently been employed as high-resolution ultra-thin endoscopes, capable of imaging biological structures deep inside tissue in vivo. Here, we extend this technique to label-free non-linear microscopy with chemical contrast using coherent anti-Stokes Raman scattering (CARS) through a multimode fibre endoscope, which opens up new avenues for instant and in-situ diagnosis of potentially malignant tissue. We use a commercial 125 µm diameter, 0.29 NA GRIN fibre, and wavefront shaping on an SLM is used to create foci that are scanned behind the fibre facet across the sample. The chemical selectivity is demonstrated by imaging 2 µm polystyrene and 2.5 µm PMMA beads with per pixel integration time as low as 1 ms for epi-detection.Multimode fibres have recently been employed as high-resolution ultra-thin endoscopes, capable of imaging biological structures deep inside tissue in vivo. Here, we extend this technique to label-free non-linear microscopy with chemical contrast using coherent anti-Stokes Raman scattering (CARS) through a multimode fibre endoscope, which opens up new avenues for instant and in-situ diagnosis of potentially malignant tissue. We use a commercial 125 µm diameter, 0.29 NA GRIN fibre, and wavefront shaping on an SLM is used to create foci that are scanned behind the fibre facet across the sample. The chemical selectivity is demonstrated by imaging 2 µm polystyrene and 2.5 µm PMMA beads with per pixel integration time as low as 1 ms for epi-detection.
  • Item
    Patterned illumination single molecule localization microscopy (piSMLM): user defined blinking regions of interest cellSTORM - Cost-effective Super-Resolution on a Cellphone using dSTORM
    (Washington D.C. : Optical Society of America, 2018) Chen, S.-Y.; Bestvater, F.; Heintzmann, Rainer; Cremer, Christoph
    Single molecule localization microscopy (SMLM) has been established as an important super-resolution technique for studying subcellular structures with a resolution down to a lateral scale of 10 nm. Usually samples are illuminated with a Gaussian shaped beam and consequently insufficient irradiance on the periphery of the illuminated region leads to artifacts in the reconstructed image which degrades image quality. We present a newly developed patterned illumination SMLM (piSMLM) to overcome the problem of uneven illumination by computer-generated holography. By utilizing a phase-only spatial light modulator (SLM) in combination with a modified Gerchberg-Saxton algorithm, a user-defined pattern with homogeneous and nearly speckle-free illumination is obtained. Our experimental results show that irradiance 1 to 5 kW/cm2 was achieved by using a laser with an output power of 200 mW in a region of 2000 µm2 to 500 µm2, respectively. Higher irradiance of up to 20 kW/cm2 can be reached by simply reducing the size of the region of interest (ROI). To demonstrate the application of the piSMLM, nuclear structures were imaged based on fluctuation binding-activated localization microscopy (fBALM). The super-resolution fBALM images revealed nuclear structures at a nanometer scale.Single molecule localization microscopy (SMLM) has been established as an important super-resolution technique for studying subcellular structures with a resolution down to a lateral scale of 10 nm. Usually samples are illuminated with a Gaussian shaped beam and consequently insufficient irradiance on the periphery of the illuminated region leads to artifacts in the reconstructed image which degrades image quality. We present a newly developed patterned illumination SMLM (piSMLM) to overcome the problem of uneven illumination by computer-generated holography. By utilizing a phase-only spatial light modulator (SLM) in combination with a modified Gerchberg-Saxton algorithm, a user-defined pattern with homogeneous and nearly speckle-free illumination is obtained. Our experimental results show that irradiance 1 to 5 kW/cm2 was achieved by using a laser with an output power of 200 mW in a region of 2000 µm2 to 500 µm2, respectively. Higher irradiance of up to 20 kW/cm2 can be reached by simply reducing the size of the region of interest (ROI). To demonstrate the application of the piSMLM, nuclear structures were imaged based on fluctuation binding-activated localization microscopy (fBALM). The super-resolution fBALM images revealed nuclear structures at a nanometer scale.
  • Item
    Tm3+/Ho3+ co-doped germanate glass double-clad fiber for broadband emission and lasing above 2 µm
    (Washington D.C. : Optical Society of America, 2019) Kochanowicz, Marcin; Zmojda, Jacek; Miluski, Piotr; Baranowska, Agata; Leich, Martin; Schwuchow, Anka; Jäger, Matthias; Kuwik, M.; Pisarska, Johanna; Pisarski, Wojciech A.; Dorosz, Dominik
    In this paper, a 2 µm broadband emission under 796 nm laser diode excitation in low phonon energy GeO2-Ga2O3-BaO glass system is co-doped with 0.7Tm2O3/(0.07-0.7)Ho2O3 (mol%). The widest emission band (where the Tm3+ → Ho3+ energy transfer efficiency is 63%) was obtained for 0.7Tm2O3/0.15Ho2O3 co-doped glass from which a double-clad optical fiber was realized and investigated. Optimization of Tm3+/Ho3+ concentration enabled the acquisition of broadband amplified spontaneous emission (ASE) in double-clad optical fiber with a full width at half maximum (FWHM): 377 nm and 662 nm for 3 dB and 10 dB bandwidth, respectively. ASE spectrum is a result of the superposition of (Tm3+: 3H4 →Η3F4) 1.45 µm, (Tm3+: 3F4 → 3H6) 1.8 µm and (Ho3+:5I7 → 5I8) 2 µm emission bands. Hence, highly rare-earth co-doped germanate glass is characterized by a remarkably broader ASE spectrum than silica and tellurite fibers showed promising lasing properties for their further application in tunable and dual wavelength lasers.In this paper, a 2 µm broadband emission under 796 nm laser diode excitation in low phonon energy GeO2-Ga2O3-BaO glass system is co-doped with 0.7Tm2O3/(0.07-0.7)Ho2O3 (mol%). The widest emission band (where the Tm3+ → Ho3+ energy transfer efficiency is 63%) was obtained for 0.7Tm2O3/0.15Ho2O3 co-doped glass from which a double-clad optical fiber was realized and investigated. Optimization of Tm3+/Ho3+ concentration enabled the acquisition of broadband amplified spontaneous emission (ASE) in double-clad optical fiber with a full width at half maximum (FWHM): 377 nm and 662 nm for 3 dB and 10 dB bandwidth, respectively. ASE spectrum is a result of the superposition of (Tm3+: 3H4 →Η3F4) 1.45 µm, (Tm3+: 3F4 → 3H6) 1.8 µm and (Ho3+:5I7 → 5I8) 2 µm emission bands. Hence, highly rare-earth co-doped germanate glass is characterized by a remarkably broader ASE spectrum than silica and tellurite fibers showed promising lasing properties for their further application in tunable and dual wavelength lasers.
  • Item
    Photonic candle – focusing light using nano-bore optical fibers
    (Washington D.C. : Optical Society of America, 2018) Schneidewind, Henrik; Zeisberger, Matthias; Plidschun, Malte; Weidlich, Stefan; Schmidt, Markus A.
    Focusing light represents one of the fundamental optical functionalities that is used in a countless number of situations. Here we introduce the concept of nano-bore optical fiber mediated light focusing that allows to efficiently focus light at micrometer distance from the fiber end face. Since the focusing effect is provided by the fundamental fiber mode, device implementation is extremely straightforward since no post-processing or nano-structuring is necessary. Far-field measurements on implemented fibers, simulations, and a dual-Gaussian beam toy model confirm the validity of the concept. Due to its unique properties such as strong light localization, a close to 100% implementation success rate, extremely high reproducibility, and its compatibility with current fiber circuitry, the concept will find application in numerous areas that demand to focus at remote distances.
  • Item
    Viscosity of fluorine-doped silica glasses
    (Washington D.C. : Optical Society of America, 2018) Kirchhof, Johannes; Unger, Sonja; Dellith, Jan
    The viscous behavior of fluorine-doped synthetic silica is studied using collapsing experiments with different fluorine-doped tubes on a modified chemical vapor deposition (MCVD) lathe. The principles, techniques, and evaluations of this method are the same as the ones demonstrated previously in detail with pure and doped silica. The present investigations provide information about the influence of fluorine doping up to a concentration of about 10 mol% F (3.4 wt% F) in a temperature range between 1600°C and 2000°C. Fluorine doping leads to a systematic decrease in the viscosity, combined with a decrease of the activation energy of the viscous flow and a certain increase of the pre-exponential factor. In summary, this demonstrates the weakening influence of fluorine on the glass network, similar to the incorporation of hydroxyl or chlorine.
  • Item
    Automated distinction of shearing and distortion artefacts in structured illumination microscopy
    (Washington D.C. : Optical Society of America, 2018) Förster, Ronny; Müller, Walter; Richter, Renè; Heintzmann, Rainer
    Any motion during an image acquisition leads to an artefact in the final image. Structured illumination microscopy (SIM) combines several raw images into one high-resolution image and is thus particularly prone to these motion artefacts. Their unpredictable shape cannot easily be distinguished from real high-resolution content. We previously implemented a motion detection specifically for SIM, which had two shortcomings which are solved here. First, the brightness dependency of the motion signal is removed. Second, the empirical threshold of the calculated motion signal was not a threshold at a maximum allowed artefact. Here we investigate which artefacts are still acceptable and which linear movement creates them. Thus, the motion signal is linked with the maximal strength of the expected artefact. A signal-to-noise analysis including classification successfully distinguishes between artefact-free imaging, shearing and distortion artefacts in biological specimens. A shearing, as in wide-field microscopy, is the dominant reconstruction artefact, while distortions arise not until surprisingly fast movements.
  • Item
    Nanotrimer enhanced optical fiber tips implemented by electron beam lithography
    (Washington D.C. : Optical Society of America, 2018) Wang, Ning; Zeisberger, Matthias; Hübner, Uwe; Schmidt, Markus A.
    Here we present a novel fabrication approach that allows for the implementation of sophisticated planar nanostructures with deep subwavelength dimensions on fiber end faces by electron beam lithography. Specifically, we planarize the end faces of fiber bundles such that they are compatible with planar nanostructuring technology, with the result that fibers can be treated in the same way as typical wafers, opening up the entire field of nanotechnology for fiber optics. To demonstrate our approach, we have implemented densely-packed arrays of gold nanotrimers on the end face of 50 cm long standard single mode fibers, showing asymmetrical resonance lineshapes that arise due to the interplay of diffractive coupling of the individual timer response at infrared wavelengths that overlap with the single mode regime of typical telecommunication fibers. Refractive index sensing experiments suggest sensitivities of about 390 nm/RIU, representing the state-of-the-art for such a device type. Due to its unique capability of making optical fibers compatible with planar nanostructuring technology, we anticipate our approach to be applied in numerous fields including bioanalytics, telecommunications, nonlinear photonics, optical trapping and beam shaping.
  • Item
    Intercomparison of far-infrared transmittance measurements
    (Washington D.C. : Optical Society of America, 2018) Kehrt, Mathias; Monte, Christian; Steiger, Andreas; Hoehl, Arne; Hollandt, Jörg; Gemünd, Hans-Peter; Brömel, Anika; Hänschke, Frank; May, Torsten; Deßmann, Nils; Hübers, Heinz-Wilhelm; Mientus, Rainald; Reck, E.
    We present the results of the first systematic “round-robin” comparison of far-infrared transmittance spectra measurements, which was performed by five laboratories and piloted by Physikalisch-Technische (PTB). The transmittance spectra of four different samples were measured by the participating laboratories in the 600 cm–1 to 10 cm–1 range (16.67 µm to 1000 µm) in a blind comparison. Different types of instruments, Fourier transform infrared (FT-IR) spectrometers of Michelson type and a laser radiation-based system were used for the transmittance measurements. FT-IR spectrometers are the most popular and commonly used instruments for the spectral characterization of materials in the infrared spectral range, and are well established for quantitative measurements in the mid- and near-infrared spectral ranges. However, obtaining quantitative transmittance measurements in the far-infrared spectral range by means of these instruments is challenging, because it involves weaker radiation sources, stronger diffraction effects, significant radiation originating from the sample itself and temperature gradients inside the spectrometer that may not be given proper consideration. Therefore, this comparison was initiated to test the actual capability of and identify problems with FT-IR transmittance measurements in this spectral region. We discuss the results and the possible reasons for the observed discrepancies.We present the results of the first systematic “round-robin” comparison of far-infrared transmittance spectra measurements, which was performed by five laboratories and piloted by Physikalisch-Technische (PTB). The transmittance spectra of four different samples were measured by the participating laboratories in the 600 cm–1 to 10 cm–1 range (16.67 µm to 1000 µm) in a blind comparison. Different types of instruments, Fourier transform infrared (FT-IR) spectrometers of Michelson type and a laser radiation-based system were used for the transmittance measurements. FT-IR spectrometers are the most popular and commonly used instruments for the spectral characterization of materials in the infrared spectral range, and are well established for quantitative measurements in the mid- and near-infrared spectral ranges. However, obtaining quantitative transmittance measurements in the far-infrared spectral range by means of these instruments is challenging, because it involves weaker radiation sources, stronger diffraction effects, significant radiation originating from the sample itself and temperature gradients inside the spectrometer that may not be given proper consideration. Therefore, this comparison was initiated to test the actual capability of and identify problems with FT-IR transmittance measurements in this spectral region. We discuss the results and the possible reasons for the observed discrepancies.
  • Item
    Wavelength dependent characterization of a multimode fibre endoscope
    (Washington D.C. : Optical Society of America, 2019) Pikálek, Tomáš; Tragardh, Johanna; Simpson, Stephen; Čižmár, Tomáš
    Multimode fibres have recently shown promise as miniature endoscopic probes. When used for non-linear microscopy, the bandwidth of the imaging system limits the ability to focus light from broadband pulsed lasers as well as the possibility of wavelength tuning during the imaging. We demonstrate that the bandwidth is limited by the dispersion of the off-axis hologram displayed on the SLM, which can be corrected for, and by the limited bandwidth of the fibre itself. The selection of the fibre is therefore crucial for these experiments. In addition, we show that a standard prism pulse compressor is sufficient for material dispersion compensation for multi-photon imaging with a fibre endoscope.