Search Results

Now showing 1 - 10 of 236
  • Item
    Author Correction: A combination of electrochemistry and mass spectrometry to monitor the interaction of reactive species with supported lipid bilayers (Scientific Reports, (2020), 10, 1, (18683), 10.1038/s41598-020-75514-7)
    (London : Nature Publishing Group, 2021) Ravandeh, M.; Kahlert, H.; Jablonowski, H.; Lackmann, J.-W.; Striesow, J.; Agmo Hernández, V.; Wende, K.
    Correction to: Scientific Reports https://doi.org/10.1038/s41598-020-75514-7, published online 29 October 2020
  • Item
    Degradation of glyphosate in water by the application of surface corona discharges
    (Bristol : IWA Publishing, 2021) Zocher, Katja; Gros, Peter; Werneburg, Matthias; Brüser, Volker; Kolb, Juergen F.; Leinweber, Peter
    Glyphosate (GLP) is one of the most widely applied herbicides, and is found ubiquitously in the environment. The removal of glyphosate from waste water and soil is challenging and can be achieved with chemical or biological methods, which, nevertheless, suffer from different disadvantages. The application of a physical plasma for the removal of GLP in water was examined by the application of surface corona discharges in a wire-to-cylinder setup filled with argon. The plasma was ignited at the liquid surface without any additives. By applying a photometric method, GLP was detected after derivatisation with fluorenyl methoxycarbonyl chloride, whereas phosphate was determined with ammonium molybdate. A GLP degradation rate of 90.8% could be achieved within a treatment time of 30 minutes with an estimated energy efficiency of 0.32 g/kWh.
  • Item
    Tumor cytotoxicity and immunogenicity of a novel V-jet neon plasma source compared to the kINPen
    (London : Nature Publishing Group, 2021) Miebach, Lea; Freund, Eric; Horn, Stefan; Niessner, Felix; Sagwal, Sanjeev Kumar; von Woedtke, Thomas; Emmert, Steffen; Weltmann, Klaus-Dieter; Clemen, Ramona; Schmidt, Anke; Gerling, Torsten; Bekeschus, Sander
    Recent research indicated the potential of cold physical plasma in cancer therapy. The plethora of plasma-derived reactive oxygen and nitrogen species (ROS/RNS) mediate diverse antitumor effects after eliciting oxidative stress in cancer cells. We aimed at exploiting this principle using a newly designed dual-jet neon plasma source (Vjet) to treat colorectal cancer cells. A treatment time-dependent ROS/RNS generation induced oxidation, growth retardation, and cell death within 3D tumor spheroids were found. In TUM-CAM, a semi in vivo model, the Vjet markedly reduced vascularized tumors' growth, but an increase of tumor cell immunogenicity or uptake by dendritic cells was not observed. By comparison, the argon-driven single jet kINPen, known to mediate anticancer effects in vitro, in vivo, and in patients, generated less ROS/RNS and terminal cell death in spheroids. In the TUM-CAM model, however, the kINPen was equivalently effective and induced a stronger expression of immunogenic cancer cell death (ICD) markers, leading to increased phagocytosis of kINPen but not Vjet plasma-treated tumor cells by dendritic cells. Moreover, the Vjet was characterized according to the requirements of the DIN-SPEC 91315. Our results highlight the plasma device-specific action on cancer cells for evaluating optimal discharges for plasma cancer treatment.
  • Item
    Acquired cancer tyrosine kinase inhibitor resistance: ROS as critical determinants
    (London : Macmillan Publishers, part of Springer Nature, 2021) Bekeschus, Sander
    [No abstract available]
  • Item
    Radiobiological effects of wound fluid on breast cancer cell lines and human-derived tumor spheroids in 2D and microfluidic culture
    ([London] : Macmillan Publishers Limited, part of Springer Nature, 2022) Jeibouei, Shabnam; Hojat, Ali; Mostafavi, Ebrahim; Aref, Amir Reza; Kalbasi, Alireza; Niazi, Vahid; Ajoudanian, Mohammad; Mohammadi, Farzaneh; Saadati, Fariba; Javadi, Seyed Mohammadreza; Shams, Forough; Moghaddam, Maryam; Karami, Farshid; Sharifi, Kazem; Moradian, Farid; Akbari, Mohammad Esmaeil; Zali, Hakimeh
    Intraoperative radiotherapy (IORT) could abrogate cancer recurrences, but the underlying mechanisms are unclear. To clarify the effects of IORT-induced wound fluid on tumor progression, we treated breast cancer cell lines and human-derived tumor spheroids in 2D and microfluidic cell culture systems, respectively. The viability, migration, and invasion of the cells under treatment of IORT-induced wound fluid (WF-RT) and the cells under surgery-induced wound fluid (WF) were compared. Our findings showed that cell viability was increased in spheroids under both WF treatments, whereas viability of the cell lines depended on the type of cells and incubation times. Both WFs significantly increased sub-G1 and arrested the cells in G0/G1 phases associated with increased P16 and P21 expression levels. The expression level of Caspase 3 in both cell culture systems and for both WF-treated groups was significantly increased. Furthermore, our results revealed that although the migration was increased in both systems of WF-treated cells compared to cell culture media-treated cells, E-cadherin expression was significantly increased only in the WF-RT group. In conclusion, WF-RT could not effectively inhibit tumor progression in an ex vivo tumor-on-chip model. Moreover, our data suggest that a microfluidic system could be a suitable 3D system to mimic in vivo tumor conditions than 2D cell culture.
  • Item
    Repeated exposure of the oral mucosa over 12 months with cold plasma is not carcinogenic in mice
    (London : Nature Publishing Group, 2021) Evert, K.; Kocher, T.; Schindler, A.; Müller, M.; Müller, K.; Pink, C.; Holtfreter, B.; Schmidt, A.; Dombrowski, F.; Schubert, A.; von Woedtke, T.; Rupf, S.; Calvisi, D. F.; Bekeschus, S.; Jablonowski, L.
    Peri-implantitis may result in the loss of dental implants. Cold atmospheric pressure plasma (CAP) was suggested to promote re-osseointegration, decrease antimicrobial burden, and support wound healing. However, the long-term risk assessment of CAP treatment in the oral cavity has not been addressed. Treatment with two different CAP devices was compared against UV radiation, carcinogen administration, and untreated conditions over 12 months. Histological analysis of 406 animals revealed that repeated CAP exposure did not foster non-invasive lesions or squamous cell carcinoma (SCCs). Carcinogen administration promoted non-invasive lesions and SCCs. Molecular analysis by a qPCR screening of 144 transcripts revealed distinct inflammatory profiles associated with each treatment regimen. Interestingly, CAP treatment of carcinogen-challenged mucosa did not promote but instead left unchanged or reduced the proportion of non-invasive lesions and SCC formation. In conclusion, repeated CAP exposure of murine oral mucosa was well tolerated, and carcinogenic effects did not occur, motivating CAP applications in patients for dental and implant treatments in the future.
  • Item
    Thermal protection implementation of the contact overheadline based on bay controllers of electric transport traction substations in the mining industry
    (Sankt-Peterburg : Inst., 2021) Lantsev, Dmitry; Frolov, Vladimir; Zverev, Sergej; Uhrlandt, Dirk; Valenta, Jiří
    The article presents the principle of thermal protection of the contact overheadlineand substantiates the possibility of practical implementation of this principle for rail electric transport in the mining industry. The algorithm for the implementation of modern digital protection of the contact overhead line as one of the functions of the controller is described. A mathematical model of thermal protection is proposed, which follows from the solution of the heat balance equation. The model takes into account the coefficient of the electrical networktopology, as well as the coefficient of consumption of the current-carrying core of the cable, which determines the reduction in the conducting section from contact erosion and the growth of oxide films. Corrections for air flows are introduced when receiving data from an external anemometer, via telemechanics protocol. The mathematical model was tested by writing a real thermal protection program in the C programming language for the bay controller, based on the circuitry of which is the STM32F407IGT6 microcontroller for the microcontroller unit. Verification tests were carried out on a serial bay controller in 2020. The graphs for comparing the calculated and actual values of temperatures, with different flow rates of the current-carrying conductor of the DC cable, are given. To obtain data, telemechanics protocols IEC 60870-104 and Modbus TCP, PLC Segnetics SMH4 were used.
  • Item
    Development of an electrochemical sensor for in-situ monitoring of reactive species produced by cold physical plasma
    (Amsterdam [u.a.] : Elsevier Science, 2021) Nasri, Zahra; Bruno, Giuliana; Bekeschus, Sander; Weltmann, Klaus-Dieter; von Woedtke, Thomas; Wende, Kristian
    The extent of clinical applications of oxidative stress-based therapies such as photodynamic therapy (PDT) or respiratory chain disruptors are increasing rapidly, with cold physical plasma (CPP) emerging as a further option. According to the current knowledge, the biological effects of CPP base on reactive oxygen and nitrogen species (RONS) relevant in cell signaling. To monitor the safety and the biological impact of the CPP, determining the local generation of RONS in the same environment in which they are going to be applied is desirable. Here, for the first time, the development of an electrochemical sensor for the simple, quick, and parallel determination of plasma-generated reactive species is described. The proposed sensor consists of a toluidine blue redox system that is covalently attached to a gold electrode surface. By recording chronoamperometry at different potentials, it is possible to follow the in-situ production of the main long-lived reactive oxygen and nitrogen species like hydrogen peroxide, nitrite, hypochlorite, and chloramine with time. The applicability of this electrochemical sensor for the in-situ assessment of reactive species in redox-based therapies is demonstrated by the precise analysis of hydrogen peroxide dynamics in the presence of blood cancer cells.
  • Item
    A combination of electrochemistry and mass spectrometry to monitor the interaction of reactive species with supported lipid bilayers
    ([London] : Macmillan Publishers Limited, part of Springer Nature, 2020) Ravandeh, M.; Kahlert, H.; Jablonowski, H.; Lackmann, J.-W.; Striesow, J.; Agmo Hernández, V.; Wende, K.
    Reactive oxygen and nitrogen species (RONS), e.g. generated by cold physical plasma (CPP) or photodynamic therapy, interfere with redox signaling pathways of mammalian cells, inducing downstream consequences spanning from migratory impairment to apoptotic cell death. However, the more austere impact of RONS on cancer cells remains yet to be clarified. In the present study, a combination of electrochemistry and high-resolution mass spectrometry was developed to investigate the resilience of solid-supported lipid bilayers towards plasma-derived reactive species in dependence of their composition. A 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) lipid bilayer was undisturbed by 200 µM H2O2 (control) but showed full permeability after CPP treatment and space-occupying oxidation products such as PoxnoPC, PAzePC, and POPC hydroperoxide were found. Electron paramagnetic resonance spectroscopy demonstrated the presence of hydroxyl radicals and superoxide anion/hydroperoxyl radicals during the treatment. In contrast, small amounts of the intramembrane antioxidant coenzyme Q10 protected the bilayer to 50% and LysoPC was the only POPC derivative found, confirming the membrane protective effect of Q10. Such, the lipid membrane composition including the presence of antioxidants determines the impact of pro-oxidant signals. Given the differences in membrane composition of cancer and healthy cells, this supports the application of cold physical plasma for cancer treatment. In addition, the developed model using the combination of electrochemistry and mass spectrometry could be a promising method to study the effect of reactive species or mixes thereof generated by chemical or physical sources.
  • Item
    Spontaneous fluctuations in a plasma ion assisted deposition – correlation between deposition conditions and vanadium oxide thin film growth
    (Amsterdam [u.a.] : Elsevier, 2021) Frank, Anna; Dias, Miguel; Hieke, Stefan; Kruth, Angela; Scheu, Christina
    In this work correlations between thin film crystallinity of plasma ion assisted electron beam evaporated vanadium oxide (VOx) and fluctuations of the deposition parameters during the growth process could be observed by in situ monitoring deposition conditions and electron microscopy studies. In the presented case, unintentional fluctuations in the gas flow at the plasma source caused by inhomogeneous melting of the target material lead to an increase in discharge current and therefore a decrease of the oxygen flow in the plasma source, resulting in the formation of highly crystalline bands due to a temporary increase in energy flux. The major part of the VOx thin film consists of a large number of nanocrystals embedded in an amorphous phase. In-depth structural analysis confirms a mixture of V2O5, in different modifications, VO2, as well as the mixed-valence oxides V4O9 and V6O13, for nanocrystalline parts and crystalline bands. These differ mainly in the degree of crystallinity being influenced by variations in discharge current, and partly in the amount of higher oxidized vanadium oxides. In future, precisely controlled variation of plasma source conditions will open up pathways to control and tailor crystallinity of electron beam evaporated thin films, allowing for production methods for patterned thin films or layers with graduated crystallinity. This may give rise to a new class of coatings of nanohybrids combining amorphous VOx with low electrical conductivity and crystalline domains providing a higher electrical conductivity which is useful for electrochromic displays, smart windows, and solar cells.