Search Results

Now showing 1 - 6 of 6
  • Item
    Hollow square core fiber sensor for physical parameters measurement
    (Bristol : IOP Publ., 2022) Pereira, Diana; Bierlich, Jörg; Kobelke, Jens; Ferreira, Marta S.
    The measurement of physical parameters is important in many current applications, since they often rely on these measurands to operate with the due quality and the necessary safety. In this work, a simple and robust optical fiber sensor based on an antiresonant hollow square core fiber (HSCF) is proposed to measure simultaneously temperature, strain, and curvature. The proposed sensor was designed in a transmission configuration where a segment of HSCF, with a 10 mm length, was spliced between two single mode fibers. In this sensor, a cladding modal interference (CMI) and a Mach-Zehnder interference (MZI) are enhanced along with the antiresonance (AR) guidance. All the present mechanisms exhibit different responses towards the physical parameters. For the temperature, sensitivities of 32.8 pm/°C, 18.9 pm/°C, and 15.7 pm/°C were respectively attained for the MZI, AR, and CMI. As for the strain, sensitivities of 0.45 pm/μϵ, -0.93 pm/μϵ, and -2.72 pm/μϵ were acquired for the MZI, AR and CMI respectively. Meanwhile, for the curvature measurements, two regions of analysis were considered. In the first region (0 m-1 - 0.7 m-1) sensitivities of 0.033 nm/m-1, -0.27 nm/m-1, and -2.21 nm/m-1 were achieved, whilst for the second region (0.7 m-1 - 1.5 m-1) sensitivities of 0.067 nm/m-1, -0.63 nm/m-1, and -0.49 nm/m-1 were acquired for the MZI, AR and CMI, respectively.
  • Item
    Correlations between the structure and superconducting properties of MT-YBaCuO
    (Bristol : IOP Publ., 2020) Prikhna, T.A.; Moshchill, V.E.; Rabier, J.; Chaud, X.; Joulain, A.; Pan, A.V.; Litskendorf, D.; Habisreuther, T.
    Comprehensive experimental results of fully oxidized (up to YBa2Cu3O6,9-7) melt-Textured YBaCuO materials with different microstructures are presented. These microstructures are built respectively: (1) with a high dislocations density but almost without twins (after high temperature treatment at 2 GPa) and (2) with a high twin density, but practically free from dislocations and stacking faults (after high temperature oxygenation at 10-16 MPa). It is shown that for attaining high critical current densities and fields of irreversibility (jc(H-c, 0 T)=9•104 A/cm2, H irr=9.7 T at 77 K), a high twin density in YBa2Cu3O6.9-7 matrix of MT-YBCO is required. The density of twins in fully oxidized materials depends on the distances between Y2BaCuO5 inclusions, larger twin densities are related to shorter distances between inclusions. The influence of phase composition of the initial powder mixtures on the distances between Y2BaCuO5 inclusions have been characterized and discussed. © Published under licence by IOP Publishing Ltd.
  • Item
    Capillary based hybrid fiber sensor in a balloon-like shape for simultaneous measurement of displacement and temperature
    (Bristol : IOP Publ., 2022) Santos, João P.; Bierlich, Jörg; Kobelke, Jens; Ferreira, Marta S.
    In this work, a hybrid sensor based on a silica capillary in a balloon-like shape for simultaneous measurement of displacement and temperature is proposed for the first time, to the best of our knowledge. The sensor is fabricated by splicing a segment of a hollow core fiber between two single mode fibers (SMF) and by bending the fiber in a balloon shape with the capillary at the top-center position. In a transmission scheme, the SMF-capillary-SMF configuration excites an antiresonant (AR) guidance and the balloon shape enhances a Mach-Zehnder interferometer (MZI). The different responses of the interferometers to external displacement and temperature variations are conducive to a hybrid application of the sensor for simultaneous measurement of these parameters. Experimental results show that, for a capillary length of 1.2 cm and a balloon length of 4 cm, AR is insensitive to displacement and its sensitivity to temperature is 14.3 pm/°C, while the MZI has a sensitivity to displacement of 1.68 nm/mm and twice the sensitivity of AR to temperature, of 28.6 pm/°C. The proposed fiber sensor consists of only one sensing element in one configuration exciting two interferometers at the same time, which makes it of simple fabrication as well as low cost.
  • Item
    Charged domains in ferroelectric, polycrystalline yttrium manganite thin films resolved with scanning electron microscopy
    (Bristol : IOP Publ., 2020) Rayapati, Venkata Rao; Bürger, Danilo; Du, Nan; Kowol, Cornelia; Blaschke, Daniel; Stöcker, Hartmut; Matthes, Patrick; Patra, Rajkumar; Skorupa, Ilona; Schulz, Stefan E.; Schmidt, Heidemarie
    We have investigated ferroelectric charged domains in polycrystalline hexagonal yttrium manganite thin films (Y1Mn1O3, Y0.95Mn1.05O3, Y1Mn0.99Ti0.01O3, and Y0.94Mn1.05Ti0.01O3) by scanning electron microscopy (SEM) in secondary electron emission mode with a small acceleration voltage. Using SEM at an acceleration voltage of 1.0 kV otherwise homogenous surface charging effects are reduced, polarization charges can be observed and polarization directions (±Pz) of the ferroelectric domains in the polycrystalline thin films can be identified. Thin films of different chemical composition have been deposited by pulsed laser deposition on Pt/SiO2/Si structures under otherwise same growth conditions. Using SEM it has been shown that different charged domain density networks are existing in polycrystalline yttrium manganite thin films. © 2020 IOP Publishing Ltd.
  • Item
    High photon count rates improve the quality of super-resolution fluorescence fluctuation spectroscopy
    (Bristol : IOP Publ., 2020) Schneider, Falk; Hernandez-Varas, Pablo; Lagerholm, B. Christoffer; Shrestha, Dilip; Sezgin, Erdinc; Roberti, M. Julia; Ossato, Giulia; Hecht, Frank; Eggeling, Christian; Urbančič, Iztok
    Probing the diffusion of molecules has become a routine measurement across the life sciences, chemistry and physics. It provides valuable insights into reaction dynamics, oligomerisation, molecular (re-)organisation or cellular heterogeneities. Fluorescence correlation spectroscopy (FCS) is one of the widely applied techniques to determine diffusion dynamics in two and three dimensions. This technique relies on the temporal autocorrelation of intensity fluctuations but recording these fluctuations has thus far been limited by the detection electronics, which could not efficiently and accurately time-tag photons at high count rates. This has until now restricted the range of measurable dye concentrations, as well as the data quality of the FCS recordings, especially in combination with super-resolution stimulated emission depletion (STED) nanoscopy. Here, we investigate the applicability and reliability of (STED-)FCS at high photon count rates (average intensities of more than 1 MHz) using novel detection equipment, namely hybrid detectors and real-time gigahertz sampling of the photon streams implemented on a commercial microscope. By measuring the diffusion of fluorophores in solution and cytoplasm of live cells, as well as in model and cellular membranes, we show that accurate diffusion and concentration measurements are possible in these previously inaccessible high photon count regimes. Specifically, it offers much greater flexibility of experiments with biological samples with highly variable intensity, e.g. due to a wide range of expression levels of fluorescent proteins. In this context, we highlight the independence of diffusion properties of cytosolic GFP in a concentration range of approx. 0.01-1 µm. We further show that higher photon count rates also allow for much shorter acquisition times, and improved data quality. Finally, this approach also pronouncedly increases the robustness of challenging live cell STED-FCS measurements of nanoscale diffusion dynamics, which we testify by confirming a free diffusion pattern for a fluorescent lipid analogue on the apical membrane of adherent cells. © The Author(s). Published by IOP Publishing Ltd.
  • Item
    Near-field interference map due to a dipolar emission near the edge of a monocrystalline gold platelet
    (Bristol : IOP Publ., 2022) Abbasirad, N.; Barreda, A.; Arslan, D.; Steinert, M.; Chen, Y.-J.; Huang, J.-S.; Staude, I.; Setzpfandt, F.; Pertsch, T.
    Point source excitation and point detection in the near-field provides new perspective to study the near-field optical phenomena of plasmonic nanostructures. Using the automated dual-tip scanning near-field optical microscope (SNOM), we have measured the optical near-field response of a dipolar emission near the edge of a monocrystalline gold platelet. The image dipole method was used to analytically calculate the interference pattern due to surface plasmon polaritons excited at the position of aperture tip and those reflected from edges of the gold platelet. The near-field enhancement was observed on the edges of the gold platelet. Our results verify that automated dual-tip SNOM is an intriguing technique for quantum plasmonic studies where deterministic coupling of quantum emitters and the detection of the near-field enhancement are of great interest.