Search Results

Now showing 1 - 8 of 8
Loading...
Thumbnail Image
Item

Digital DC blocker filters

2021, Tittelbach-Helmrich, Klaus

This paper mathematically investigates a special kind of digital infinite-impulse response (IIR) filters, suitable for filtering out very low frequencies near zero from digital signals. We investigate the transfer functions of such filters from 1st to 3rd order and provide formulas to calculate the filter coefficients from the desired cutoff frequency.

Loading...
Thumbnail Image
Item

Photonic contact thermometry using silicon ring resonators and tuneable laser-based spectroscopy

2021, Eisermann, René, Krenek, Stephan, Winzer, Georg, Rudtsch, Steffen

Photonic sensors offer the possibility of purely optical measurement in contact thermometry. In this work, silicon-based ring resonators were used for this purpose. These can be manufactured with a high degree of reproducibility and uniformity due to the established semiconductor manufacturing process. For the precise characterisation of these photonic sensors, a measurement setup was developed which allows laser-based spectroscopy around 1550 nm and stable temperature control from 5 °C to 95 °C. This was characterised in detail and the resulting uncertainty influences of both the measuring set-up and the data processing were quantified. The determined temperature stability at 20 °C is better than 0.51 mK for the typical acquisition time of 10 s for a 100 nm spectrum. For a measurement of >24 h at 30 °C a standard deviation of 2.6 mK could be achieved. A hydrogen cyanide reference gas cell was used for traceable in-situ correction of the wavelength. The determined correction function has a typical uncertainty of 0.6 pm. The resonance peaks of the ring resonators showed a high optical quality of 157 000 in the average with a filter depth of up to 20 dB in the wavelength range from 1525 nm to 1565 nm. When comparing different methods for the determination of the central wavelength of the resonance peaks, an uncertainty of 0.3 pm could be identified. A temperature-dependent shift of the resonance peaks of approx. 72 pm/K was determined. This temperature sensitivity leads together with the analysed uncertainty contributions to a repeatability of better than 10 mK in the analysed temperature range from 10 °C to 90 °C.

Loading...
Thumbnail Image
Item

A modular in vitro flow model to analyse blood-surface interactions under physiological conditions

2021, Valtin, Juliane, Behrens, Stephan, Maitz, Manfred F., Schmieder, Florian, Sonntag, Frank, Werner, Carsten

Newly developed materials for blood-contacting devices need to undergo hemocompatibility testing to prove compliance with clinical requirements. However, many current in vitro models disregard the influence of flow conditions and blood exchange as it occurs in vivo. Here, we present a flow model which allows testing of blood-surface interactions under more physiological conditions. This modular platform consists of a triple-pump-chip and a microchannel-chip with a customizable surface. Flow conditions can be adjusted individually within the physiological range. A performance test with whole blood confirmed the hemocompatibility of our modular platform. Hemolysis was negligible, inflammation and hemostasis parameters were comparable to those detected in a previously established quasi-static whole blood screening chamber. The steady supply of fresh blood avoids secondary effects by nonphysiological accumulation of activation products. Experiments with three subsequently tested biomaterials showed results similar to literature and our own experience. The reported results suggest that our developed flow model allows the evaluation of blood-contacting materials under physiological flow conditions. By adjusting the occurring wall shear stress, the model can be adapted for selected test conditions.

Loading...
Thumbnail Image
Item

Messanlage zur Untersuchung des Seebeck-Effektes in Polymermaterialien

2020, Jenschke, Wolfgang, Ullrich, Mathias, Krause, Beate, Pötschke, Petra

The thermoelectric effect named after the physicist Thomas Johann Seebeck has been investigated sufficiently well for all technically relevant metals and has been used for a long time, among other things, for temperature measurement by means of thermocouples. Less well known and researched is the Seebeck effect in polymer materials, which are gaining increasing influence in the sensor industry today. This article describes a measuring system designed specifically to study the Seebeck effect in polymeric samples with the aim of developing tailored polymers for sensory engineering applications using the Seebeck effect. The special requirement of the measuring system is the realization of constant accurate temperature sources.

Loading...
Thumbnail Image
Item

NFDI4Chem - A Research Data Network for International Chemistry

2023, Steinbeck, Christoph, Koepler, Oliver, Herres-Pawlis, Sonja, Bach, Felix, Jung, Nicole, Razum, Matthias, Liermann, Johannes C., Neumann, Steffen

Research data provide evidence for the validation of scientific hypotheses in most areas of science. Open access to them is the basis for true peer review of scientific results and publications. Hence, research data are at the heart of the scientific method as a whole. The value of openly sharing research data has by now been recognized by scientists, funders and politicians. Today, new research results are increasingly obtained by drawing on existing data. Many organisations such as the Research Data Alliance (RDA), the goFAIR initiative, and not least IUPAC are supporting and promoting the collection and curation of research data. One of the remaining challenges is to find matching data sets, to understand them and to reuse them for your own purpose. As a consequence, we urgently need better research data management.

Loading...
Thumbnail Image
Item

Open Access im Blick! Mehr Sichtbarkeit von Open-Access-Publikationen in der Bibliothek – Projekt visOA

2020, Geith, Uwe, Kraß, Thomas

In order to bring Open Access publications more into the perception of library users, it is necessary to make them more visible. In the visOA project, carried out by the NTNM library of the INM, Open Access publications were clearly highlighted in the OPAC as well as in the Discovery System and in the publication lists of the INM. A self-programmed virtual journal display (VIDIJO) also offers a subject-specific selection of Open Access journals. The effectiveness of the measures taken in the project was verified by accompanying research.

Loading...
Thumbnail Image
Item

Hydrophobic multiscale cavities for high-performance and self-cleaning surface-enhanced Raman spectroscopy (SERS) sensing

2020, Zhao, Xiaofei, Liu, Chundong, Yu, Jing, Liu, Lu, Li, Chonghui, Xu, Shicai, Li, Weifeng, Man, Baoyuan, Zhang, Chao

Cavity array, with excellent optical capture capability, has received increasing attention for the surface-enhanced Raman spectroscopy (SERS)-active substrates. Here, we proposed molybdenum disulfide (MoS2) nanocavities growing on pyramid Si (PSi) composed of in situ reduced Au nanoparticles (AuNPs), which can form the multiscale cavities (MSCs), and is facile for the couple of the plasmon. We demonstrated that the PSi/MoS2/Au MSCs can serve as highly sensitive, uniform, and stable SERS substrates for rhodamine 6G (R6G), crystal violet, and adenosine triphosphate detection, benefiting from the synergistic effect of the enhanced light trapping and the effective plasmonic couple. The couple of the plasmon in the MSCs is evidently proved by finite-difference time domain simulation, showing the strong electromagnetic field is located around the cavity wall. Moreover, the excellent hydrophobicity of the PSi/MoS2/AuNPs substrate endows it with the ability for the directional monitoring of organic pollutant in a mixture of oil and water. Finally, we demonstrated the MSCs with outstanding photocatalytic performance could achieve the renewable utilization by self-cleaning, which was attributed to the fast electron transfer and effective light absorption. The proposed PSi/MoS2/AuNPs MSC represents a robust mean using the plasmonic metal/semiconductor heterostructure for high-performance SERS sensors and photodegradation.

Loading...
Thumbnail Image
Item

Detecting Bacteria on Wounds with Hyperspectral Imaging in Fluorescence Mode

2020, Hornberger, Christoph., Herrmann, Bert. H., Daeschlein, Georg, Podewils, Sebastian von, Sicher, Claudia, Kuhn, Jana, Masur, Kai, Meister, Mareike, Wahl, Philip

Chronic non-healing wounds represent an increasing problem. In order to enable physicians and nurses to make evidence based decisions on wound treatment, the professional societies call for supporting tools to be offered to physicians. Oxygen supply, bacteria colonization and other parameters influence the healing process. So far, these parameters cannot be monitored in an objective and routinely manner. Existing methods like the microbiological analysis of wound swabs, mean a great deal of effort and partly a long delay. In this paper 42 fluorescence images from 42 patients with diabetic foot ulcer, recorded with a hyperspectral imaging system (TIVITA®), converted for fluorescence imaging, were analysed. Beside the fluorescence images, information about the bacterial colonization is available from microbiological analysis of wound swabs. After preprocessing, principal component analysis, PCA, is used for data analysis with a 405 nm excitation wavelength, the emission wavelength range 510 - 745 nm is used for analysis. After dividing the data into a training and a test dataset it could be shown, that bacteria are detectable in the wound area. A quantification in bacterial colonization counts (BCC) was not in the focus of the research in this study stage.