Search Results

Now showing 1 - 10 of 50
  • Item
    Inactivation of airborne bacteria by plasma treatment and ionic wind for indoor air cleaning
    (Hoboken, NJ : Wiley Interscience, 2020) Prehn, Franziska; Timmermann, Eric; Kettlitz, Manfred; Schaufler, Katharina; Günther, Sebastian; Hahn, Veronika
    Airborne bacteria are a general problem in medical or health care facilities with a high risk for nosocomial infections. Rooms with a continuous airflow, such as operation theaters, are of particular importance due to a possible dissemination and circulation of pathogens including multidrug-resistant microorganisms. In this regard, a cold atmospheric-pressure plasma (CAP) may be a possibility to support usual disinfection procedures due to its decontaminating properties. The aim of this study was to determine the antimicrobial efficacy of a plasma decontamination module that included a dielectric barrier discharge for plasma generation. Experimental parameters such as an airflow velocity of 4.5 m/s and microbial contaminations of approximately 6,000 colony-forming units (cfu)/m3 were used to simulate practical conditions of a ventilation system in an operating theater. The apathogenic microorganism Escherichia coli K12 DSM 11250/NCTC 10538 and the multidrug-resistant strains E. coli 21181 and 21182 (isolated from patients) were tested to determine the antimicrobial efficacy. In summary, the number of cfu was reduced by 31–89% for the tested E. coli strains, whereby E. coli K12 was the most susceptible strain toward inactivation by the designed plasma module. A possible correlation between the number or kind of resistances and susceptibility against plasma was discussed. The inactivation of microorganisms was affected by plasma intensity and size of the plasma treatment area. In addition, the differences of the antimicrobial efficacies caused through the nebulization of microorganisms in front (upstream) or behind (downstream) the plasma source were compared. The presence of ionic wind had no influence on the reduction of the number of cfu for E. coli K12, as the airflow velocity was too high for a successful precipitation, which would be a prerequisite for an increased antimicrobial efficacy. The inactivation of the tested microorganisms confirms the potential of CAP for the improvement of air quality. The scale-up of this model system may provide a novel tool for an effective air cleaning process.
  • Item
    Foundations of plasmas for medical applications
    (Bristol : IOP Publ., 2022) von Woedtke, T.; Laroussi, M.; Gherardi, M.
    Plasma medicine refers to the application of nonequilibrium plasmas at approximately body temperature, for therapeutic purposes. Nonequilibrium plasmas are weakly ionized gases which contain charged and neutral species and electric fields, and emit radiation, particularly in the visible and ultraviolet range. Medically-relevant cold atmospheric pressure plasma (CAP) sources and devices are usually dielectric barrier discharges and nonequilibrium atmospheric pressure plasma jets. Plasma diagnostic methods and modelling approaches are used to characterize the densities and fluxes of active plasma species and their interaction with surrounding matter. In addition to the direct application of plasma onto living tissue, the treatment of liquids like water or physiological saline by a CAP source is performed in order to study specific biological activities. A basic understanding of the interaction between plasma and liquids and bio-interfaces is essential to follow biological plasma effects. Charged species, metastable species, and other atomic and molecular reactive species first produced in the main plasma ignition are transported to the discharge afterglow to finally be exposed to the biological targets. Contact with these liquid-dominated bio-interfaces generates other secondary reactive oxygen and nitrogen species (ROS, RNS). Both ROS and RNS possess strong oxidative properties and can trigger redox-related signalling pathways in cells and tissue, leading to various impacts of therapeutic relevance. Dependent on the intensity of plasma exposure, redox balance in cells can be influenced in a way that oxidative eustress leads to stimulation of cellular processes or oxidative distress leads to cell death. Currently, clinical CAP application is realized mainly in wound healing. The use of plasma in cancer treatment (i.e. plasma oncology) is a currently emerging field of research. Future perspectives and challenges in plasma medicine are mainly directed towards the control and optimization of CAP devices, to broaden and establish its medical applications, and to open up new plasma-based therapies in medicine.
  • Item
    Terahertz quantum-cascade lasers for high-resolution absorption spectroscopy of atoms and ions in plasmas
    (Bristol : IOP Publ., 2023) Lü, X.; Röben, B.; Biermann, K.; Wubs, J.R.; Macherius, U.; Weltmann, K.-D.; van Helden, J.H.; Schrottke, L.; Grahn, H.T.
    We report on terahertz (THz) quantum-cascade lasers (QCLs) based on GaAs/AlAs heterostructures, which exhibit single-mode emission at 3.360, 3.921, and 4.745 THz. These frequencies are in close correspondence to fine-structure transitions of Al atoms, N+ ions, and O atoms, respectively. Due to the low electrical pump power of these THz QCLs, they can be operated in a mechanical cryocooler in continuous-wave mode, while a sufficient intrinsic tuning range of more than 5 GHz is maintained. The single-mode operation and the intrinsic tuning range of these THz QCLs allow for the application of these lasers as radiation sources for high-resolution absorption spectroscopy to determine the absolute densities of Al atoms, N+ ions, and O atoms in plasmas.
  • Item
    Upscaling from single- to multi-filament dielectric barrier discharges in pulsed operation
    (Bristol : IOP Publ., 2022) Höft, H.; Becker, M.M.; Kettlitz, M.; Brandenburg, R.
    A study on the scalability of discharge characteristics of a single-filament dielectric barrier discharge (DBD) to a spatially one-dimensional multi-filament arrangement driven by the same high-voltage (HV) pulses was performed for a gas mixture of 0.1 vol% O2 in N2 at 1 bar. Both arrangements feature a 1 mm gap with dielectric-covered electrodes featuring two hemispherical alumina caps for the single-filament and two parallel alumina-tubes for the multi-filament arrangement. The DBDs were characterised by electrical measurements (for peak current, energy, and power) accompanied by iCCD and streak imaging to determine the filament number and the discharge development in the gas gap and on the surfaces. It was found that the electrical quantities scale with a constant factor between the single- and multi-filament arrangement, which is expected to be related to the filament number. In the multi-filament arrangement, the pulsed operation leads to filament formation in the entire gap in lateral direction within less than 2 ns. Furthermore, particular breakdown or discharge inception regimes were identified for the multi-filament DBDs. These regimes could be generated at the falling slope of asymmetrical HV pulses featuring e.g. a double-streamer propagation, which was previously reported for single-filament DBDs. Consequently, it was proven that the discharge manipulation by varying the HV pulse widths obtained for single-filament DBDs can also be applied in a one-dimensional multi-filament arrangement, i.e. an upscaling based on the knowledge for single-filament DBDs seems to be generally possible.
  • Item
    Effect of cold atmospheric pressure plasma treatment of eggshells on the total bacterial count inoculated Salmonella Enteritidis and selected quality parameters
    (Hoboken, NJ : Wiley Interscience, 2021) Moritz, Maike; Wiacek, Claudia; Weihe, Thomas; Ehlbeck, Jörg; Weltmann, Klaus‐Dieter; Braun, Peggy G.
    In the European Union, foodborne outbreaks caused by Salmonella Enteritidis, related to eggs and egg products, have even been reported in 2018. Atmospheric pressure plasma is becoming increasingly important as a decontamination method. A semidirect cold atmospheric pressure plasma, the flexible electrode plasma source, was developed for treating whole hen's eggs. An average reduction of 1.16 and 0.95 log colony-forming units (CFU)/egg was achieved for the total bacterial count of clean and dirty eggs, respectively. An inactivation of 4.1 log CFU/egg Salmonella Enteritidis was achieved with artificially inoculated eggshells. Selected quality parameters and sensory properties were analysed. Overall, the present study yielded promising results for a realistic implementation of an industrial prototype plasma source.
  • Item
    Plasma medical oncology: Immunological interpretation of head and neck squamous cell carcinoma
    (Hoboken, NJ : Wiley Interscience, 2020) Witzke, Katharina; Seebauer, Christian; Jesse, Katja; Kwiatek, Elisa; Berner, Julia; Semmler, Marie‐Luise; Boeckmann, Lars; Emmert, Steffen; Weltmann, Klaus‐Dieter; Metelmann, Hans‐Robert; Bekeschus, Sander
    The prognosis of patients suffering from advanced-stage head and neck squamous cell carcinoma (HNSCC) remains poor. Medical gas plasma therapy receives growing attention as a novel anticancer modality. Our recent prospective observational study on HNSCC patients suffering from contaminated tumor ulcerations without lasting remission after first-line anticancer therapy showed remarkable efficacy of gas plasma treatment, with the ulcerated tumor surface decreasing by up to 80%. However, tumor growth relapsed, and this biphasic response may be a consequence of immunological and molecular changes in the tumor microenvironment that could be caused by (a) immunosuppression, (b) tumor cell adaption, (c) loss of microbe-induced immunostimulation, and/or (d) stromal cell adaption. These considerations may be vital for the design of clinical plasma trials in the future.
  • Item
    Double-propagation mode in short-gap spark discharges driven by HV pulses with sub-ns rise time
    (Bristol : IOP Publ., 2020) Höft, H.; Becker, M.M.; Kolb, J.F.; Huiskamp, T.
    The object of this study is the investigation of spark discharges ignited by unipolar positive rectangular high voltage (HV) pulses with 200 ps rise time and (15 ± 2) kV amplitude with 3 ns duration full width at half maximum in synthetic air in a 1.2 mm pin-to-pin gap (tungsten electrodes) at atmospheric pressure. The discharge development was recorded by synchronised iCCD and streak camera measurements in single-shot operation, revealing a two-stage propagation mode. The discharge started with a fast initial breakdown across the entire gap (∼10 mm ns−1) during the HV slope, followed by a much slower (∼0.1 mm ns−1) propagation originating from both electrodes towards the gap centre. The combination of high-resolution diagnostics with numerical modelling indicated that the initial breakdown phase is caused by the rapid increase of electric field strength during the steep HV slope, which leads to the simultaneous fast propagation of a positive and a negative streamer.
  • Item
    Impedimetric Analysis of Trabecular Bone Based on Cole and Linear Discriminant Analysis
    (Lausanne : Frontiers Media, 2021) Wei, Wenzuo; Shi, Fukun; Kolb, Juergen F.
    A spatially unambiguous characterization of electrical properties of osseous tissues is important for the therapy of osteopathy via electrical stimulation. Accordingly, the study aimed to characterize the highly inhomogeneous composition and structures of different anatomical regions of trabecular bone based on their electrical properties. The electrical properties of 64 porcine trabecular bone samples were analyzed in a parallel plate electrode configuration and compared with published results. Therefore, a novel method, combining traditional Cole model with a linear discriminant analysis (LDA), was developed to discriminate the different regions, i.e., femur head, greater trochanter, and femur neck. Possible mechanisms behind the distinction for different regions could be interpreted from both methods. Respective adjacent regions with similar structure and composition could be distinguished from statistically significant differences of Cole parameters, i.e., α (p < 0.01) and R∞ (p < 0.05). The latter was correlated especially with water content, indicating an association of individual differences in microstructures in particular with conductivity. Conversely, different regions were unambiguously discriminated with LDA based on permittivity or conductivity. Contributions to the discrimination were explicitly reflected by the coefficients of the derived LDA features. A clear distinction was obtained especially for a frequency response at 950 kHz. Moreover, predictions for the classification of unspecified samples assigned them correctly to their origin with a success of 92.9%. The combination of both methods offers the possibility for a spatially resolved and eventually patient specific discrimination and evaluation of bone tissues and their response to therapies, notably electrical stimulation.
  • Item
    High-Performance GaAs/AlAs Terahertz Quantum-Cascade Lasers for Spectroscopic Applications
    (New York, NY : IEEE, 2020) Schrottke, Lutz; Lü, Xiang; Röben, Benjamin; Biermann, Klaus; Hagelschuer, Till; Wienold, Martin; Hübers, Heinz-Wilhelm; Hannemann, Mario; van Helden, Jean-Pierre H.; Röpcke, Jürgen; Grahn, Holger T.
    We have developed terahertz (THz) quantum-cascade lasers (QCLs) based on GaAs/AlAs heterostructures for application-defined emission frequencies between 3.4 and 5.0 THz. Due to their narrow line width and rather large intrinsic tuning range, these THz QCLs can be used as local oscillators in airborne or satellite-based astronomical instruments or as radiation sources for high-resolution absorption spectroscopy, which is expected to allow for a quantitative determination of the density of atoms and ions in plasma processes. The GaAs/AlAs THz QCLs can be operated in mechanical cryocoolers and even in miniature cryocoolers due to the comparatively high wall-plug efficiency of around 0.2% and typical current densities below 500 A/cm$^2$. These lasers emit output powers of more than 1 mW at operating temperatures up to about 70 K, which is sufficient for most of the abovementioned applications. © 2011-2012 IEEE.
  • Item
    Electric field determination in transient plasmas: in situ & non-invasive methods
    (Bristol : IOP Publ., 2022) Goldberg, Benjamin M.; Hoder, Tomáš; Brandenburg, Ronny
    One of the primary basic plasma parameters within transient nonequilibrium plasmas is the reduced electric field strength, roughly understood as the ratio of the electrical energy given to the charged species between two collisions. While physical probes have historically been used for electric field measurements, recent advances in high intensity lasers and sensitive detection methods have allowed for non-invasive optical electric field determination in nearly any discharge configuration with time-resolution up to the sub-nanosecond range and sub-millimeter spatial resolution. This topical review serves to highlight several non-invasive methods for in situ electric field strength determination in transient plasmas ranging from high vacuum environments to atmospheric pressure and above. We will discuss the advantages and proper implementation of (i) laser induced fluorescence dip spectroscopy for measurements in low pressure RF discharges, (ii) optical emission spectroscopy based methods for nitrogen, helium or hydrogen containing discharges, (iii) electric field induced coherent Raman scattering, and (iv) electric field induced second harmonic generation. The physical mechanism for each method will be described as well as basic implementation and highlighting recent results.