Search Results

Now showing 1 - 7 of 7
  • Item
    Melt mixed composites of polypropylene with singlewalled carbon nanotubes for thermoelectric applications: Switching from p- to n-type behavior by additive addition
    (Melville, NY : AIP, 2019) Pötschke; Petra; Krause, Beate; Luo, Jinji
    Composites were prepared with polypropylene (PP) as the matrix and singlewalled CNTs (SWCNTs) of the type TUBALL from OCSiAl Ltd. as the conducting component by melt processing in a small-scale twin-screw compounder. In order to switch the typical p-type behavior of such composites from positive Seebeck coefficients (S) into n-type behavior with negative Seebeck coefficients, a non-ionic surfactant polyoxyethylene 20 cetyl ether (Brij58) was used and compared with a PEG additive, which was shown previously to be able to induce such switching. For PP-2 wt% SWCNT composites Brij58 is shown to result in n-type composites. The negative S values (up to −48.2 µV/K) are not as high as in the case of previous results using PEG (−56.6 µV/K). However, due to the more pronounced effect of Brij58 on the electrical conductivity, the achieved power factors are higher and reach a maximum of 0.144 µW/(m·K2) compared to previous 0.078 µW/(m·K2) with PEG. Dispersion improvement depends on the type of SWCNTs obtained by using varied synthesis/treatment conditions. Solution prepared composites of PEG with SWCNTs also have negative S values, indicating the donation of electrons from PEG to the SWCNTs. However, such composites are brittle and not suitable as thermoelectric materials.
  • Item
    Nonenzymatic post-translational modifications in peptides by cold plasma-derived reactive oxygen and nitrogen species
    (Melville, NY : AIP, 2020) Wenske, Sebastian; Lackmann, Jan-Wilm; Bekeschus, Sander; Weltmann, Klaus-Dieter; Von Woedtke, Thomas; Wende, Kristian
    Cold physical plasmas are emerging tools for wound care and cancer control that deliver reactive oxygen species (ROS) and nitrogen species (RNS). Alongside direct effects on cellular signaling processes, covalent modification of biomolecules may contribute to the observed physiological consequences. The potential of ROS/RNS generated by two different plasma sources (kINPen and COST-Jet) to introduce post-translational modifications (PTMs) in the peptides angiotensin and bradykinin was explored. While the peptide backbone was kept intact, a significant introduction of oxidative PTMs was observed. The modifications cluster at aromatic (tyrosine, histidine, and phenylalanine) and neutral amino acids (isoleucine and proline) with the introduction of one, two, or three oxygen atoms, ring cleavages of histidine and tryptophan, and nitration/nitrosylation predominantly observed. Alkaline and acidic amino acid (arginine and aspartic acid) residues showed a high resilience, indicating that local charges and the chemical environment at large modulate the attack of the electron-rich ROS/RNS. Previously published simulations, which include only OH radicals as ROS, do not match the experimental results in full, suggesting the contribution of other short-lived species, i.e., atomic oxygen, singlet oxygen, and peroxynitrite. The observed PTMs are relevant for the biological activity of peptides and proteins, changing polarity, folding, and function. In conclusion, it can be assumed that an introduction of covalent oxidative modifications at the amino acid chain level occurs during a plasma treatment. The introduced changes, in part, mimic naturally occurring patterns that can be interpreted by the cell, and subsequently, these PTMs allow for prolonged secondary effects on cell physiology. © 2020 Author(s).
  • Item
    Influence of a supplemental filler in twin-screw extruded PP/CNT composites using masterbatch dilution
    (Melville, NY : AIP, 2019) Müller, Michael Thomas; Krause, Beate; Kretzschmar, Bernd; Pötschke, Petra
    In this study commercially available multiwalled carbon nanotubes (2-8 wt.%) were incorporated in polypropylene (PP) by direct powder feeding or by a masterbatch dilution procedure using a twin-screw extruder. The influence of a supplemental, electrical non-conductive talc or electrically conductive carbon black (CB), filler on the resulting composite properties was investigated. In comparison to the direct carbon nanotube (CNT) incorporation the masterbatch dilution step resulted in improved CNT macro dispersion. The use of the supplemental fillers CB or talc does not show a significant influence on the CNT dispersion state. When compared to direct CNT incorporation, the second compounding process involved in masterbatch dilution leads to higher electrical resistivity of injection molded samples. On the other hand, the supplemental fillers talc or CB decreased the electrical resistivity values. With the addition of talc or CB an increase of the Young’s modulus due to the reinforcing effect of the second filler was achieved. However, no synergistic effect between the used supplemental fillers and the CNT on the mechanical properties was obtained.
  • Item
    Epitaxial synthesis of unintentionally doped p-type SnO (001) via suboxide molecular beam epitaxy
    (Melville, NY : AIP, 2023) Egbo, Kingsley; Luna, Esperanza; Lähnemann, Jonas; Hoffmann, Georg; Trampert, Achim; Grümbel, Jona; Kluth, Elias; Feneberg, Martin; Goldhahn, Rüdiger; Bierwagen, Oliver
    By employing a mixed SnO2 + Sn source, we demonstrate suboxide molecular beam epitaxy (S-MBE) growth of phase-pure single-crystalline metastable SnO (001) thin films on Y-stabilized ZrO2 (001) substrates at a growth rate of ∼1.0 nm/min without the need for additional oxygen. These films grow epitaxially across a wide substrate temperature range from 150 to 450 °C. Hence, we present an alternative pathway to overcome the limitations of high Sn or SnO2 cell temperatures and narrow growth windows encountered in previous MBE growth of metastable SnO. In situ laser reflectometry and line-of-sight quadrupole mass spectrometry were used to investigate the rate of SnO desorption as a function of substrate temperature. While SnO ad-molecule desorption at TS = 450 °C was growth-rate limiting, the SnO films did not desorb at this temperature after growth in vacuum. The SnO (001) thin films are transparent and unintentionally p-type doped, with hole concentrations and mobilities in the range of 0.9-6.0 × 1018 cm-3 and 2.0-5.5 cm2 V-1 s-1, respectively. These p-type SnO films obtained at low substrate temperatures are promising for back-end-of-line (BEOL) compatible applications and for integration with n-type oxides in pn heterojunctions and field-effect transistors.
  • Item
    Development of joining methods for highly filled Graphite/PP composite based bipolar plates for fuel cells: Adhesive joining and welding
    (Melville, NY : AIP, 2019) Rzeczkowski, P.; Lucia, M.; Müller, A.; Facklam, M.; Cohnen, A.; Schäfer, P.; Hopmann, C.; Hickmann, T.; Pötschke, Petra; Krause, Beate
    Novel material solutions for bipolar plates in fuel cells require adapted ways of joining and sealing technologies. Safe and life time enduring leak-tight contacts must be achieved by automatic processes using reasonable joint forces. A proper sealing should manage such challenges as good ageing properties, excellent leaktightness, high thermal conductivity and low gas permeability. Hence in this work, adhesive bonding and welding are considered as suitable methods, which can fulfill the requirements mentioned above. Adhesive systems seem to be more easy to apply than conventional sealing (hand layed-up rubber gaskets), e.g. with automatic dispensers. Additionally, the properties of an adhesive joint can be enhanced by a process-specific surface pre-treatment. This work focuses on the characterization of adhesive systems and their joints with highly filled graphite composites. Mechanical properties of the joints were characterized through lap-shear tests. The influence of ageing caused by humidity or acidic solvent at increased temperature on the bond line properties as well as neat adhesive was examined. The thermal conductivities of neat adhesives and through the entire joint were examined. In order to improve above conductivities, roughening, substrate pre-heating, post-curing and various contact pressure weights were applied. Plasma treatment was chosen as surface pre-treatment method for improving substrate's surface energy. An alternative to bonding is plastic welding, which does not require the use of sealants and adhesives. Based on former study of influences of filler content on the welding process using ultrasonic, hot plate or infrared welding, a welding method for joining the graphite compounds was derived.
  • Item
    Improvement of electrical resistivity of highly filled graphite/pp composite based bipolar plates for fuel cells by addition of carbon black
    (Melville, NY : AIP, 2019) Krause, Beate; Pötschke, Petra; Hickmann, Thorsten
    Novel material solutions for polymer based bipolar plates in fuel cells require adapted ways to develop suitable material compositions. The common pathway to develop materials with at the same time high electrical as well as thermal conductivity is the use of conductive graphite as filler with contents up to 80-85 wt.%. However, there is a need to develop recipes with maximized conductive behavior at lowest possible content of conductive filler to enhance the mechanical properties and allow good processability. In this study, composites based on polypropylene (PP) and different filler systems were melt-mixed using a lab scale co-rotating twin-screw extruder and compression molded to bipolar type plates. As fillers synthetic (G) or expanded (EG) graphites were incorporated. At the overall filler content of 60 wt.% or 80 wt% part of the graphite was replaced by highly conductive carbon black (CB, 2.5 wt.%, 5.0 wt.%). It was found that the addition of CB significantly reduced the electrical volume as well as the surface resistivity up to values of 0.12 Ωcm or 4 mΩ/square, respectively. For the values of thermal conductivity the kind and particle size of the selected graphite was important. If expanded graphite was partially replaced by CB, the thermal conductivity of PP/EG+CB composites decreased significantly. Otherwise, the combination of synthetic graphite and CB changed the thermal conductivity of PP composites only marginal at the same overall filler content. For both graphite types the filler with larger particle size resulted in higher thermal conductivity.
  • Item
    Surface cleaning and sample carrier for complementary high-resolution imaging techniques
    (Melville, NY : AIP, 2020) Benettoni, Pietro; Ye, Jia-Yu; Holbrook, Timothy R.; Calabrese, Federica; Wagner, Stephan; Zarejousheghani, Mashaalah; Griebe, Jan; Ullrich, Maria K.; Musat, Niculina; Schmidt, Matthias; Flyunt, Roman; Reemtsma, Thorsten; Richnow, Hans-Hermann; Stryhanyuk, Hryhoriy
    Nowadays, high-resolution imaging techniques are extensively applied in a complementary way to gain insights into complex phenomena. For a truly complementary analytical approach, a common sample carrier is required that is suitable for the different preparation methods necessary for each analytical technique. This sample carrier should be capable of accommodating diverse analytes and maintaining their pristine composition and arrangement during deposition and preparation. In this work, a new type of sample carrier consisting of a silicon wafer with a hydrophilic polymer coating was developed. The robustness of the polymer coating toward solvents was strengthened by cross-linking and stoving. Furthermore, a new method of UV-ozone cleaning was developed that enhances the adhesion of the polymer coating to the wafer and ensures reproducible surface-properties of the resulting sample carrier. The hydrophilicity of the sample carrier was recovered applying the new method of UV-ozone cleaning, while avoiding UV-induced damages to the polymer. Noncontact 3D optical profilometry and contact angle measurements were used to monitor the hydrophilicity of the coating. The hydrophilicity of the polymer coating ensures its spongelike behavior so that upon the deposition of an analyte suspension, the solvent and solutes are separated from the analyte by absorption into the polymer. This feature is essential to limit the coffee-ring effect and preserve the native identity of an analyte upon deposition. The suitability of the sample carrier for various sample types was tested using nanoparticles from suspension, bacterial cells, and tissue sections. To assess the homogeneity of the analyte distribution and preservation of sample integrity, optical and scanning electron microscopy, helium ion microscopy, laser ablation inductively coupled plasma mass spectrometry, and time-of-flight secondary ion mass spectrometry were used. This demonstrates the broad applicability of the newly developed sample carrier and its value for complementary imaging. © 2020 Author(s).