Search Results

Now showing 1 - 5 of 5
  • Item
    Different types of spin currents in the comprehensive materials database of nonmagnetic spin Hall effect
    (London : Nature Publ. Group, 2021) Zhang, Yang; Xu, Qiunan; Koepernik, Klaus; Rezaev, Roman; Janson, Oleg; Železný, Jakub; Jungwirth, Tomáš; Felser, Claudia; van den Brink, Jeroen; Sun, Yan
    Spin Hall effect (SHE) has its special position in spintronics. To gain new insight into SHE and to identify materials with substantial spin Hall conductivity (SHC), we performed high-precision high-throughput ab initio calculations of the intrinsic SHC for over 20,000 nonmagnetic crystals. The calculations revealed a strong relationship between the magnitude of the SHC and the crystalline symmetry, where a large SHC is typically associated with mirror symmetry-protected nodal line band structures. This database includes 11 materials with an SHC comparable to or even larger than that of Pt. Materials with different types of spin currents were additionally identified. Furthermore, we found that different types of spin current can be obtained by rotating applied electrical fields. This improves our understanding and is expected to facilitate the design of new types of spin-orbitronic devices.
  • Item
    Blood platelet enrichment in mass-producible surface acoustic wave (SAW) driven microfluidic chips
    (Cambridge : RSC, 2019) Richard, Cynthia; Fakhfouri, Armaghan; Colditz, Melanie; Striggow, Friedrich; Kronstein-Wiedemann, Romy; Tonn, Torsten; Medina-Sánchez, Mariana; Schmidt, Oliver G.; Gemming, Thomas; Winkler, Andreas
    The ability to separate specific biological components from cell suspensions is indispensable for liquid biopsies, and for personalized diagnostics and therapy. This paper describes an advanced surface acoustic wave (SAW) based device designed for the enrichment of platelets (PLTs) from a dispersion of PLTs and red blood cells (RBCs) at whole blood concentrations, opening new possibilities for diverse applications involving cell manipulation with high throughput. The device is made of patterned SU-8 photoresist that is lithographically defined on the wafer scale with a new proposed methodology. The blood cells are initially focused and subsequently separated by an acoustic radiation force (ARF) applied through standing SAWs (SSAWs). By means of flow cytometric analysis, the PLT concentration factor was found to be 7.7, and it was proven that the PLTs maintain their initial state. A substantially higher cell throughput and considerably lower applied powers than comparable devices from literature were achieved. In addition, fully coupled 3D numerical simulations based on SAW wave field measurements were carried out to anticipate the coupling of the wave field into the fluid, and to obtain the resulting pressure field. A comparison to the acoustically simpler case of PDMS channel walls is given. The simulated results show an ideal match to the experimental observations and offer the first insights into the acoustic behavior of SU-8 as channel wall material. The proposed device is compatible with current (Lab-on-a-Chip) microfabrication techniques allowing for mass-scale, reproducible chip manufacturing which is crucial to push the technology from lab-based to real-world applications. © The Royal Society of Chemistry.
  • Item
    Magnetofluidic platform for multidimensional magnetic and optical barcoding of droplets
    (Cambridge : RSC, 2014) Lin, Gungun; Makarov, Denys; Medina-Sánchez, Mariana; Guix, Maria; Baraban, Larysa; Cuniberti, Gianaurelio; Schmidt, Oliver G.
    We present a concept of multidimensional magnetic and optical barcoding of droplets based on a magnetofluidic platform. The platform comprises multiple functional areas, such as an encoding area, an encoded droplet pool and a magnetic decoding area with integrated giant magnetoresistive (GMR) sensors. To prove this concept, penicillin functionalized with fluorescent dyes is coencapsulated with magnetic nanoparticles into droplets. While fluorescent dyes are used as conventional optical barcodes which are decoded with an optical decoding setup, an additional dimensionality of barcodes is created by using magnetic nanoparticles as magnetic barcodes for individual droplets and integrated micro-patterned GMR sensors as the corresponding magnetic decoding devices. The strategy of incorporating a magnetic encoding scheme provides a dynamic range of ~40 dB in addition to that of the optical method. When combined with magnetic barcodes, the encoding capacity can be increased by more than 1 order of magnitude compared with using only optical barcodes, that is, the magnetic platform provides more than 10 unique magnetic codes in addition to each optical barcode. Besides being a unique magnetic functional element for droplet microfluidics, the platform is capable of on-demand facile magnetic encoding and real-time decoding of droplets which paves the way for the development of novel non-optical encoding schemes for highly multiplexed droplet-based biological assays.
  • Item
    Electron beam induced dehydrogenation of MgH2 studied by VEELS
    (Cham : Springer International Publishing AG, 2016) Surrey, Alexander; Schultz, Ludwig; Rellinghaus, Bernd
    Nanosized or nanoconfined hydrides are promising materials for solid-state hydrogen storage. Most of these hydrides, however, degrade fast during the structural characterization utilizing transmission electron microscopy (TEM) upon the irradiation with the imaging electron beam due to radiolysis. We use ball-milled MgH2 as a reference material for in-situ TEM experiments under low-dose conditions to study and quantitatively understand the electron beam-induced dehydrogenation. For this, valence electron energy loss spectroscopy (VEELS) measurements are conducted in a monochromated FEI Titan3 80–300 microscope. From observing the plasmonic absorptions it is found that MgH2 successively converts into Mg upon electron irradiation. The temporal evolution of the spectra is analyzed quantitatively to determine the thickness-dependent, characteristic electron doses for electron energies of both 80 and 300 keV. The measured electron doses can be quantitatively explained by the inelastic scattering of the incident high-energy electrons by the MgH2 plasmon. The obtained insights are also relevant for the TEM characterization of other hydrides.
  • Item
    Accuracy and Precision in Electronic Structure Computation: Wien2k and FPLO
    (Basel : MDPI, 2022) Richter, Manuel; Kim, Seo-Jin; Koepernik, Klaus; Rosner, Helge; Möbius, Arnulf
    Electronic structure calculations in the framework of density functional theory are based on complex numerical codes which are used in a multitude of applications. Frequently, existing experimental information is used as a gauge for the reliability of such codes. However, their results depend both on the chosen exchange-correlation energy functional and on the specific numerical implementation of the Kohn-Sham equations. The only way to disentangle these two items is a direct comparison of two or more electronic structure codes. Here, we address the achievable numerical accuracy and numerical precision in the total energy computation of the two all-electron density-functional codes Wien2k and FPLO. Both codes are based on almost independent numerical implementations and largely differ in the representation of the Bloch wave function. Thus, it is a highly encouraging result that the total energy data obtained with both codes agree within less than 10−6. We here relate the term numerical accuracy to the value of the total energy E, while the term numerical precision is related to the numerical noise of E as observed in total energy derivatives. We find that Wien2k achieves a slightly higher accuracy than FPLO at the price of a larger numerical effort. Further, we demonstrate that the FPLO code shows somewhat higher precision, i.e., less numerical noise in E than Wien2k, which is useful for the evaluation of physical properties based on derivatives of E.