Search Results

Now showing 1 - 4 of 4
  • Item
    Polarization manipulation of surface acoustic waves by metallization patterns on a piezoelectric substrate
    (Melville, NY : AIP Publishing, 2020) Weser, R.; Darinskii, A.N.; Schmidt, H.
    Surface acoustic waves (SAWs) with large normal (vertical) surface displacement at the surface are commonly utilized in microfluidic actuators in order to provide the desired momentum transfer to the fluid. We present an alternative concept using a SAW with comparatively small vertical displacement. Such a SAW passes underneath the microfluidic vessel walls with minimum losses but it needs to be converted inside the vessel into surface vibrations with large vertical displacements. The principal operability of the above idea is illustrated by experimental and numerical studies of the polarization conversion of a leaky SAW on 64° rotated Y-cut of lithium niobate owing to the partial metallization of the substrate surface. In particular, it is found that vertical displacements on the metallized surface can be up to 3.5 times higher as compared to their values on the free surface. Results of computations agree reasonably well with measurements carried out with a laser Doppler vibrometer and allow the clarification of some specific features of this polarization conversion by means of spatial frequency analysis. © 2020 Author(s).
  • Item
    Cryo-printed microfluidics enable rapid prototyping for optical-cell analysis
    (Heidelberg : Springer, 2022) Garmasukis, Rokas; Hackl, Claudia; Dusny, Christian; Elsner, Christian; Charvat, Ales; Schmid, Andreas; Abel, Bernd
    This paper highlights an innovative, low-cost rapid-prototyping method for generating microfluidic chips with extraordinary short fabrication times of only a few minutes. Microchannels and inlet/outlet ports are created by controlled deposition of aqueous microdroplets on a cooled surface resulting in printed ice microstructures, which are in turn coated with a UV-curable acrylic cover layer. Thawing leaves an inverse imprint as a microchannel structure. For an exemplary case, we applied this technology for creating a microfluidic chip for cell-customized optical-cell analysis. The chip design includes containers for cell cultivation and analysis. Container shape, length, position, and angle relative to the main channel were iteratively optimized to cultivate and analyze different cell types. With the chip, we performed physiological analyses of morphologically distinct prokaryotic Corynebacterium glutamicum DM1919, eukaryotic Hansenula polymorpha RB11 MOX-GFP, and phototrophic Synechocystis sp. PCC 6803 cells via quantitative time-lapse fluorescence microscopy. The technology is not limited to rapid prototyping of complex biocompatible microfluidics. Further exploration may include printing with different materials other than water, printing on other substrates in-situ biofunctionalization, the inclusion of electrodes and many other applications.
  • Item
    Continuous electroosmotic sorting of particles in grooved microchannels
    (London : Royal Soc. of Chemistry, 2017) Dubov, Alexander L.; Molotilin, Taras Y.; Vinogradova, Olga I.
    We propose a novel microfluidic fractionation concept suitable for neutrally buoyant micron-sized particles. This approach takes advantage of the ability of grooved channel walls oriented at an angle to the direction of an external electric field to generate a transverse electroosmotic flow. Using computer simulations, we first demonstrate that the velocity of this secondary transverse flow depends on the distance from the wall, so neutrally buoyant particles, depending on their size and initial location, will experience different lateral displacements. We then optimize the geometry and orientation of the surface texture of the channel walls to maximize the efficiency of particle fractionation. Our method is illustrated in a full scale computer experiment where we mimic the typical microchannel with a bottom grooved wall and a source of polydisperse particles that are carried along the channel by the forward electroosmotic flow. Our simulations show that the particle dispersion can be efficiently separated by size even in a channel that is only a few texture periods long. These results can guide the design of novel microfluidic devices for efficient sorting of microparticles.
  • Item
    The complexity of surface acoustic wave fields used for microfluidic applications
    (Amsterdam [u.a.] : Elsevier, 2020) Weser, R.; Winkler, A.; Weihnacht, M.; Menzel, S.; Schmidt, H.
    Using surface acoustic waves (SAW) for the agitation and manipulation of fluids and immersed particles or cells in lab-on-a-chip systems has been state of the art for several years. Basic tasks comprise fluid mixing, atomization of liquids as well as sorting and separation (or trapping) of particles and cells, e.g. in so-called acoustic tweezers. Even though the fundamental principles governing SAW excitation and propagation on anisotropic, piezoelectric substrates are well-investigated, the complexity of wave field effects including SAW diffraction, refraction and interference cannot be comprehensively simulated at this point of time with sufficient accuracy. However, the design of microfluidic actuators relies on a profound knowledge of SAW propagation, including superposition of multiple SAWs, to achieve the predestined functionality of the devices. Here, we present extensive experimental results of high-resolution analysis of the lateral distribution of the complex displacement amplitude, i.e. the wave field, alongside with the electrical S-parameters of the generating transducers. These measurements were carried out and are compared in setups utilizing travelling SAW (tSAW) excited by single interdigital transducer (IDT), standing SAW generated between two IDTs (1DsSAW, 1D acoustic tweezers) and between two pairs of IDTs (2DsSAW, 2D acoustic tweezers) with different angular alignment in respect to pure Rayleigh mode propagation directions and other practically relevant orientations. For these basic configurations, typically used to drive SAW-based microfluidics, the influence of common SAW phenomena including beam steering, coupling coefficient dispersion and diffraction on the resultant wave field is investigated. The results show how tailoring of the acoustic conditions, based on profound knowledge of the physical effects, can be achieved to finally realize a desired behavior of a SAW-based microacoustic-fluidic system. © 2020 Elsevier B.V.