Search Results

Now showing 1 - 10 of 13
  • Item
    Gratings for synchrotron and FEL beamlines: a project for the manufacture of ultra-precise gratings at Helmholtz Zentrum Berlin
    (Chester : IUCr, 2018) Siewert, F.; Löchel, B.; Buchheim, J.; Eggenstein, F.; Firsov, A.; Gwalt, G.; Kutz, O.; Lemke, St.; Nelles, B.; Rudolph, I.; Schäfers, F.; Seliger, T.; Senf, F.; Sokolov, A.; Waberski, Ch.; Wolf, J.; Zeschke, T.; Zizak, I.; Follath, R.; Arnold, T.; Frost, F.; Pietag, F.; Erko, A.
    Blazed gratings are of dedicated interest for the monochromatization of synchrotron radiation when a high photon flux is required, such as, for example, in resonant inelastic X-ray scattering experiments or when the use of laminar gratings is excluded due to too high flux densities and expected damage, for example at free-electron laser beamlines. Their availability became a bottleneck since the decommissioning of the grating manufacture facility at Carl Zeiss in Oberkochen. To resolve this situation a new technological laboratory was established at the Helmholtz Zentrum Berlin, including instrumentation from Carl Zeiss. Besides the upgraded ZEISS equipment, an advanced grating production line has been developed, including a new ultra-precise ruling machine, ion etching technology as well as laser interference lithography. While the old ZEISS ruling machine GTM-6 allows ruling for a grating length up to 170 mm, the new GTM-24 will have the capacity for 600 mm (24 inch) gratings with groove densities between 50 lines mm−1 and 1200 lines mm−1. A new ion etching machine with a scanning radiofrequency excited ion beam (HF) source allows gratings to be etched into substrates of up to 500 mm length. For a final at-wavelength characterization, a new reflectometer at a new Optics beamline at the BESSY-II storage ring is under operation. This paper reports on the status of the grating fabrication, the measured quality of fabricated items by ex situ and in situ metrology, and future development goals.
  • Item
    XUV double-pulses with femtosecond to 650 ps separation from a multilayer-mirror-based split-and-delay unit at FLASH
    (Chester : IUCr, 2018-8-3) Sauppe, Mario; Rompotis, Dimitrios; Erk, Benjamin; Bari, Sadia; Bischoff, Tobias; Boll, Rebecca; Bomme, Cédric; Bostedt, Christoph; Dörner, Simon; Düsterer, Stefan; Feigl, Torsten; Flückiger, Leonie; Gorkhover, Tais; Kolatzki, Katharina; Langbehn, Bruno; Monserud, Nils; Müller, Erland; Müller, Jan P.; Passow, Christopher; Ramm, Daniel; Rolles, Daniel; Schubert, Kaja; Schwob, Lucas; Senfftleben, Björn; Treusch, Rolf; Ulmer, Anatoli; Weigelt, Holger; Zimbalski, Jannis; Zimmermann, Julian; Möller, Thomas; Rupp, Daniela
    Extreme ultraviolet (XUV) and X-ray free-electron lasers enable new scientific opportunities. Their ultra-intense coherent femtosecond pulses give unprecedented access to the structure of undepositable nanoscale objects and to transient states of highly excited matter. In order to probe the ultrafast complex light-induced dynamics on the relevant time scales, the multi-purpose end-station CAMP at the free-electron laser FLASH has been complemented by the novel multilayer-mirror-based split-and-delay unit DESC (DElay Stage for CAMP) for time-resolved experiments. XUV double-pulses with delays adjustable from zero femtoseconds up to 650 picoseconds are generated by reflecting under near-normal incidence, exceeding the time range accessible with existing XUV split-and-delay units. Procedures to establish temporal and spatial overlap of the two pulses in CAMP are presented, with emphasis on the optimization of the spatial overlap at long time-delays via time-dependent features, for example in ion spectra of atomic clusters.
  • Item
    The 1-Megapixel pnCCD detector for the Small Quantum Systems Instrument at the European XFEL: system and operation aspects
    (Chester : IUCr, 2021) Kuster, Markus; Ahmed, Karim; Ballak, Kai Erik; Danilevski, Cyril; Ekmedžić, Marko; Fernandes, Bruno; Gessler, Patrick; Hartmann, Robert; Hauf, Steffen; Holl, Peter; Meyer, Michael; Montaño, Jacobo; Münnich, Astrid; Ovcharenko, Yevheniy; Rennhack, Nils; Rüter, Tonn; Rupp, Daniela; Schlosser, Dieter; Setoodehnia, Kiana; Schmitt, Rüdiger; Strüder, Lothar; Tanyag, Rico Mayro P.; Ulmer, Anatoli; Yousef, Hazem
    The X-ray free-electron lasers that became available during the last decade, like the European XFEL (EuXFEL), place high demands on their instrumentation. Especially at low photon energies below 1 keV, detectors with high sensitivity, and consequently low noise and high quantum efficiency, are required to enable facility users to fully exploit the scientific potential of the photon source. A 1-Megapixel pnCCD detector with a 1024 × 1024 pixel format has been installed and commissioned for imaging applications at the Nano-Sized Quantum System (NQS) station of the Small Quantum System (SQS) instrument at EuXFEL. The instrument is currently operating in the energy range between 0.5 and 3 keV and the NQS station is designed for investigations of the interaction of intense FEL pulses with clusters, nano-particles and small bio-molecules, by combining photo-ion and photo-electron spectroscopy with coherent diffraction imaging techniques. The core of the imaging detector is a pn-type charge coupled device (pnCCD) with a pixel pitch of 75 µm × 75 µm. Depending on the experimental scenario, the pnCCD enables imaging of single photons thanks to its very low electronic noise of 3 e− and high quantum efficiency. Here an overview on the EuXFEL pnCCD detector and the results from the commissioning and first user operation at the SQS experiment in June 2019 are presented. The detailed descriptions of the detector design and capabilities, its implementation at EuXFEL both mechanically and from the controls side as well as important data correction steps aim to provide useful background for users planning and analyzing experiments at EuXFEL and may serve as a benchmark for comparing and planning future endstations at other FELs.
  • Item
    A new concept for temporal gating of synchrotron X-ray pulses
    (Chester : IUCr, 2021) Schmidt, D.; Bauer, R.; Chung, S.; Novikov, D.; Sander, M.; Pudell, J.E.; Herzog, M.; Pfuetzenreuter, D.; Schwarzkopf, J.; Chernikov, R.; Gaal, P.
    A new concept for temporal gating of synchrotron X-ray pulses based on laser-induced thermal transient gratings is presented. First experimental tests of the concept yield a diffraction efficiency of 0.18%; however, the calculations indicate a theoretical efficiency and contrast of >30% and 10−5, respectively. The full efficiency of the pulse picker has not been reached yet due to a long-range thermal deformation of the sample after absorption of the excitation laser. This method can be implemented in a broad spectral range (100 eV to 20 keV) and is only minimally invasive to an existing setup.
  • Item
    Beam damage of single semiconductor nanowires during X-ray nanobeam diffraction experiments
    (Chester : IUCr, 2020) Al Hassan, Ali; Lähnemann, Jonas; Davtyan, Arman; Al-Humaidi, Mahmoud; Herranz, Jesús; Bahrami, Danial; Anjum, Taseer; Bertram, Florian; Dey, Arka Bikash; Geelhaar, Lutz; Pietsch, Ullrich
    Nanoprobe X-ray diffraction (nXRD) using focused synchrotron radiation is a powerful technique to study the structural properties of individual semiconductor nanowires. However, when performing the experiment under ambient conditions, the required high X-ray dose and prolonged exposure times can lead to radiation damage. To unveil the origin of radiation damage, a comparison is made of nXRD experiments carried out on individual semiconductor nanowires in their as-grown geometry both under ambient conditions and under He atmosphere at the microfocus station of the P08 beamline at the third-generation source PETRA III. Using an incident X-ray beam energy of 9 keV and photon flux of 1010 s-1, the axial lattice parameter and tilt of individual GaAs/In0.2Ga0.8As/GaAs core-shell nanowires were monitored by continuously recording reciprocal-space maps of the 111 Bragg reflection at a fixed spatial position over several hours. In addition, the emission properties of the (In,Ga)As quantum well, the atomic composition of the exposed nanowires and the nanowire morphology were studied by cathodoluminescence spectroscopy, energy-dispersive X-ray spectroscopy and scanning electron microscopy, respectively, both prior to and after nXRD exposure. Nanowires exposed under ambient conditions show severe optical and morphological damage, which was reduced for nanowires exposed under He atmosphere. The observed damage can be largely attributed to an oxidation process from X-ray-induced ozone reactions in air. Due to the lower heat-transfer coefficient compared with GaAs, this oxide shell limits the heat transfer through the nanowire side facets, which is considered as the main channel of heat dissipation for nanowires in the as-grown geometry.
  • Item
    CAMP@FLASH: an end-station for imaging, electron- and ion-spectroscopy, and pump–probe experiments at the FLASH free-electron laser
    (Chester : IUCr, 2018-8-2) Erk, Benjamin; Müller, Jan P.; Bomme, Cédric; Boll, Rebecca; Brenner, Günter; Chapman, Henry N.; Correa, Jonathan; Düsterer, Stefan; Dziarzhytski, Siarhei; Eisebitt, Stefan; Graafsma, Heinz; Grunewald, Sören; Gumprecht, Lars; Hartmann, Robert; Hauser, Günter; Keitel, Barbara; von Korff Schmising, Clemens; Kuhlmann, Marion; Manschwetus, Bastian; Mercadier, Laurent; Müller, Erland; Passow, Christopher; Plönjes, Elke; Ramm, Daniel; Rompotis, Dimitrios; Rudenko, Artem; Rupp, Daniela; Sauppe, Mario; Siewert, Frank; Schlosser, Dieter; Strüder, Lothar; Swiderski, Angad; Techert, Simone; Tiedtke, Kai; Tilp, Thomas; Treusch, Rolf; Schlichting, Ilme; Ullrich, Joachim; Moshammer, Robert; Möller, Thomas; Rolles, Daniel
    The non-monochromatic beamline BL1 at the FLASH free-electron laser facility at DESY was upgraded with new transport and focusing optics, and a new permanent end-station, CAMP, was installed. This multi-purpose instrument is optimized for electron- and ion-spectroscopy, imaging and pump–probe experiments at free-electron lasers. It can be equipped with various electron- and ion-spectrometers, along with large-area single-photon-counting pnCCD X-ray detectors, thus enabling a wide range of experiments from atomic, molecular, and cluster physics to material and energy science, chemistry and biology. Here, an overview of the layout, the beam transport and focusing capabilities, and the experimental possibilities of this new end-station are presented, as well as results from its commissioning.
  • Item
    Sample chamber for synchrotron based in-situ X-ray diffraction experiments under electric fields and temperatures between 100 K and 1250 K
    (Chester : IUCr, 2021) Nentwich, Melanie; Weigel, Tina; Richter, Carsten; Stöcker, Hartmut; Mehner, Erik; Jachalke, Sven; Novikov, Dmitri V.; Zschornak, Matthias; Meyer, Dirk C.
    Many scientific questions require X-ray experiments conducted at varying temperatures, sometimes combined with the application of electric fields. Here, a customized sample chamber developed for beamlines P23 and P24 of PETRA III at DESY to suit these demands is presented. The chamber body consists mainly of standard vacuum parts housing the heater/cooler assembly supplying a temperature range of 100 K to 1250 K and an xyz manipulator holding an electric contact needle for electric measurements at both high voltage and low current. The chamber is closed by an exchangeable hemispherical dome offering all degrees of freedom for single-crystal experiments within one hemisphere of solid angle. The currently available dome materials (PC, PS, PEEK polymers) differ in their absorption and scattering characteristics, with PEEK providing the best overall performance. The article further describes heating and cooling capabilities, electric characteristics, and plans for future upgrades of the chamber. Examples of applications are discussed.
  • Item
    Tetra­carbonyl-2κ4C-[μ-5-methyl-1,1,3-triphenyl-2-(propan-2-yl)-2,4-di­aza-1,3-diphosphahexan-4-ido-1κN4:2κP1,P3](N,N,N′,N′-tetra­methyl­ethane-1,2-di­amine-1κ2N,N′)lithiummolybdenum
    (Chester : IUCr, 2018) Höhne, Martha; Spannenberg, Anke; Müller, Bernd H.; Peulecke, Normen; Rosenthal, Uwe
    The title complex, [LiMo(C6H16N2)(C24H29N2P2)(CO)4], contains a distorted octa­hedrally coordinated molybdenum centre bearing a li­thia­ted P,P′-cis-chelating PNPN ligand, which results in a nearly planar four-membered metallacycle. The Li atom is coordinated by one equivalent tetra­methyl­ethylenedi­amine. In the crystal, mol­ecules are linked via weak C—H...O inter­actions, forming a chain along the b-axis direction.
  • Item
    Tetra­carbon­yl[N-(di­phenyl­phosphanyl-κP)-N,N′-diisoprop­yl-P-phenyl­phospho­rus di­amide-κP]molybdenum(0) with an unknown solvent
    (Chester : IUCr, 2018) Höhne, Martha; Gongoll, Marc; Spannenberg, Anke; Müller, Bernd H.; Peulecke, Normen; Rosenthal, Uwe
    The title complex, [Mo(C24H30N2P2)(CO)4], contains a molybdenum centre bearing a P,P′-cis-chelating Ph2PN(iPr)P(Ph)NH(iPr) and four carbonyl ligands in a distorted octa­hedral coordination geometry. This results in a nearly planar four-membered metallacycle. In the crystal, mol­ecules are linked by N—H...O and C—H...O hydrogen bonds to form layers parallel to the ac plane. For the final refinement, the contributions of disordered solvent mol­ecules were removed from the diffraction data with SQUEEZE in PLATON [Spek (2015). Acta Cryst. C71, 9–18]. The given chemical formula and other crystal data do not take into account the unknown solvent mol­ecule(s).
  • Item
    1-Benzyl-3-methylimidazolium bromide
    (Chester : IUCr, 2020) Peppel, Tim; Wulf, Christoph; Spannenberg, Anke
    [no abstract available]