Search Results

Now showing 1 - 6 of 6
Loading...
Thumbnail Image
Item

Enhanced reliability of drift-diffusion approximation for electrons in fluid models for nonthermal plasmas

2013, Becker, M.M., Loffhagen, D.

Common fluid models used for the description of electron transport in nonthermal discharge plasmas are subject to substantial restrictions if the electron energy transport significantly influences the discharge behaviour. A drift-diffusion approach is presented which is based on a multiterm approximation of the electron velocity distribution function and overcomes some of these restrictions. It is validated using a benchmark model and applied for the analysis of argon discharge plasmas at low and atmospheric pressure. The results are compared to those of common drift-diffusion models as well as to experimental data. It is pointed out that fluid models are able to describe nonlocal phenomena caused by electron energy transport, if the energy transport is consistently described. Numerical difficulties that frequently occur when the conventional drift-diffusion model is consistently applied are avoided by the proposed method.

Loading...
Thumbnail Image
Item

The combination of plasma-processed air (PPA) and plasma-treated water (PTW) causes synergistic inactivation of Candida albicans SC5314

2020, Schnabel, Uta, Yarova, Kateryna, Zessin, Björn, Stachowiak, Jörg, Ehlbeck, Jörg

Microwave-induced plasma was used for the generation of plasma-processed air (PPA) and plasma-treated water (PTW). By this way, the plasma was able to functionalize the compressed air and the used water to antimicrobial effective agents. Their fungicidal effects by single and combined application were investigated on Candida albicans strain SC5314. The monoculture of C. albicans was cultivated on specimens with polymeric surface structures (PE-stripes). The additive as well as the synergistic fungicidal potential of PPA and PTW was investigated by different process windows of plasma exposure time (5-50 s) and sample treatment time with PPA/PTW (1-5 min). For a single PTW or PPA treatment, an increase in the reduction factor with the indicated treatment time was observed (maximum reduction factor of 1.1 and 1.6, respectively). In comparison, the combined application of PTW and then PPA resulted in antagonistic, additive and synergistic effects, depending on the combination. An application of the synergistically acting processes of PTW for cleaning and PPA for drying can be an innovative alternative to the sanitary processes currently used in production plants. © 2020 by the authors.

Loading...
Thumbnail Image
Item

Impact of plasma jet vacuum ultraviolet radiation on reactive oxygen species generation in bio-relevant liquids

2015, Jablonowski, H., Bussiahn, R., Hammer, M.U., Weltmann, K.-D., von Woedtke, T., Reuter, S.

Plasma medicine utilizes the combined interaction of plasma produced reactive components. These are reactive atoms, molecules, ions, metastable species, and radiation. Here, ultraviolet (UV, 100–400 nm) and, in particular, vacuum ultraviolet (VUV, 10–200 nm) radiation generated by an atmospheric pressure argon plasma jet were investigated regarding plasma emission, absorption in a humidified atmosphere and in solutions relevant for plasma medicine. The energy absorption was obtained for simple solutions like distilled water (dH2O) or ultrapure water and sodium chloride (NaCl) solution as well as for more complex ones, for example, Rosewell Park Memorial Institute (RPMI 1640) cell culture media. As moderate stable reactive oxygen species, hydrogen peroxide (H2O2) was studied. Highly reactive oxygen radicals, namely, superoxide anion (O2•−) and hydroxyl radicals (•OH), were investigated by the use of electron paramagnetic resonance spectroscopy. All species amounts were detected for three different treatment cases: Plasma jet generated VUV and UV radiation, plasma jet generated UV radiation without VUV part, and complete plasma jet including all reactive components additionally to VUV and UV radiation. It was found that a considerable amount of radicals are generated by the plasma generated photoemission. From the experiments, estimation on the low hazard potential of plasma generated VUV radiation is discussed.

Loading...
Thumbnail Image
Item

Plasma-treated air and water-assessment of synergistic antimicrobial effects for sanitation of food processing surfaces and environment

2019, Schnabel, Uta, Handorf, Oliver, Yarova, Kateryna, Zessin, Björn, Zechlin, Susann, Sydow, Diana, Zellmer, Elke, Stachowiak, Jörg, Andrasch, Mathias, Below, Harald, Ehlbeck, Jörg

The synergistic antimicrobial effects of plasma-processed air (PPA) and plasma-treated water (PTW), which are indirectly generated by a microwave-induced non-atmospheric pressure plasma, were investigated with the aid of proliferation assays. For this purpose, microorganisms (Listeria monocytogenes, Escherichia coli, Pectobacterium carotovorum, sporulated Bacillus atrophaeus) were cultivated as monocultures on specimens with polymeric surface structures. Both the distinct and synergistic antimicrobial potential of PPA and PTW were governed by the plasma-on time (5–50 s) and the treatment time of the specimens with PPA/PTW (1–5 min). In single PTW treatment of the bacteria, an elevation of the reduction factor with increasing treatment time could be observed (e.g., reduction factor of 2.4 to 3.0 for P. carotovorum). In comparison, the combination of PTW and subsequent PPA treatment leads to synergistic effects that are clearly not induced by longer treatment times. These findings have been valid for all bacteria (L. monocytogenes > P. carotovorum = E. coli). Controversially, the effect is reversed for endospores of B. atrophaeus. With pure PPA treatment, a strong inactivation at 50 s plasma-on time is detectable, whereas single PTW treatment shows no effect even with increasing treatment parameters. The use of synergistic effects of PTW for cleaning and PPA for drying shows a clear alternative for currently used sanitation methods in production plants. Highlights: Non-thermal atmospheric pressure microwave plasma source used indirect in two different modes—gaseous and liquid; Measurement of short and long-living nitrite and nitrate in corrosive gas PPA (plasma-processed air) and complex liquid PTW (plasma-treated water); Application of PTW and PPA in single and combined use for biological decontamination of different microorganisms.

Loading...
Thumbnail Image
Item

Treatment of Candida albicans biofilms with low-temperature plasma induced by dielectric barrier discharge and atmospheric pressure plasma jet

2010, Koban, I., Matthes, R., Hübner, N.-O., Welk, A., Meisel, P., Holtfreter, B., Sietmann, R., Kindel, E., Weltmann, K.-D., Kramer, A., Kocher, T.

Because of some disadvantages of chemical disinfection in dental practice (especially denture cleaning), we investigated the effects of physical methods on Candida albicans biofilms. For this purpose, the antifungal efficacy of three different low-temperature plasma devices (an atmospheric pressure plasma jet and two different dielectric barrier discharges (DBDs)) on Candida albicans biofilms grown on titanium discs in vitro was investigated. As positive treatment controls, we used 0.1% Chlorhexidine digluconate (CHX) and 0.6% sodium hypochlorite (NaOCl). The corresponding gas streams without plasma ignition served as negative treatment controls. The efficacy of the plasma treatment was determined evaluating the number of colony-forming units (CFU) recovered from titanium discs. The plasma treatment reduced the CFU significantly compared to chemical disinfectants. While 10 min CHX or NaOCl exposure led to a CFU log 10 reduction factor of 1.5, the log10 reduction factor of DBD plasma was up to 5. In conclusion, the use of low-temperature plasma is a promising physical alternative to chemical antiseptics for dental practice. © IOP Publishing Ltd and Deutsche Physikalische Gesellschaft.

Loading...
Thumbnail Image
Item

Nitric oxide density distributions in the effluent of an RF argon APPJ: Effect of gas flow rate and substrate

2014, Iseni, S., Zhang, S., Van Gessel, A.F.H., Hofmann, S., Van Ham, B.T.J., Reuter, S., Weltmann, K.-D., Bruggeman, P.J.

The effluent of an RF argon atmospheric pressure plasma jet, the so-called kinpen, is investigated with focus on the nitric-oxide (NO) distribution for laminar and turbulent flow regimes. An additional dry air gas curtain is applied around the plasma effluent to prevent interaction with the ambient humid air. By means of laser-induced fluorescence (LIF) the absolute spatially resolved NO density is measured as well as the rotational temperature and the air concentration. While in the laminar case, the transport of NO is attributed to thermal diffusion; in the turbulent case, turbulent mixing is responsible for air diffusion. Additionally, measurements with a molecular beam mass-spectrometer (MBMS) absolutely calibrated for NO are performed and compared with the LIF measurements. Discrepancies are explained by the contribution of the NO2 and N2O to the MBMS NO signal. Finally, the effect of a conductive substrate in front of the plasma jet on the spatial distribution of NO and air diffusion is also investigated.