Search Results

Now showing 1 - 2 of 2
  • Item
    Investigation on the potential of applying bio-based edible coatings for horticultural products exemplified with cucumbers
    (Amsterdam : Elsevier, 2022) Rux, G.; Labude, C.; Herppich, W.B.; Geyer, M.
    Plastic packaging for fresh horticultural produce has many advantages but generates plastic waste and ecological alternatives are required. Edible coatings can retard many processes related to loss of quality. Hydrophobic lipid-based coatings are preferably applied for fresh fruits and vegetables. The approval of such coatings for products with edible peels in EU is increasingly under discussion. However, investigations on the efficiency of various edible coatings on soft-skinned fruit and vegetables are rare and it is currently unclear whether the consumer will accept them. Therefore, this study investigates (1) important characteristics of a lipid-based coating and (2) its ability to maintain the post-harvest quality of fresh cucumbers. This was evaluated by a comparative storage test under common suboptimal retail conditions (20 °C; 65% RH). The study also evaluates (3) the general perception of consumers about and their acceptance of the application of edible coatings on fresh fruit and vegetables with edible peels. The investigated coating was able to drastically reduce water loss (54–68%) and fruit respiration (approx. 33%) of fresh cucumber. The reduction of tissue stiffness was delayed by 2 days, thus, prolonged shelf life. Majority of consumer (77%) endorse the application of edible coatings as an alternative to plastic packaging, but emphasized important requirements for them.
  • Item
    Determination of the Entire Stent Surface Area by a New Analytical Method
    (Basel : MDPI, 2020) Saqib, Muhammad; Bernhardt, Ricardo; Kästner, Markus; Beshchasna, Natalia; Cuniberti, Gianaurelio; Opitz, Jörg
    Stenting is a widely used treatment procedure for coronary artery disease around the world. Stents have a complex geometry, which makes the characterization of their corrosion difficult due to the absence of a mathematical model to calculate the entire stent surface area (ESSA). Therefore, corrosion experiments with stents are mostly based on qualitative analysis. Additionally, the quantitative analysis of corrosion is conducted with simpler samples made of stent material instead of stents, in most cases. At present, several methods are available to calculate the stent outer surface area (SOSA), whereas no model exists for the calculation of the ESSA. This paper presents a novel mathematical model for the calculation of the ESSA using the SOSA as one of the main parameters. The ESSA of seven magnesium alloy stents (MeKo Laser Material Processing GmbH, Sarstedt, Germany) were calculated using the developed model. The calculated SOSA and ESSA for all stents are 33.34%(±0.26%) and 111.86 mm (±0.85 mm), respectively. The model is validated by micro-computed tomography (micro-CT), with a difference of 12.34% (±0.46%). The value of corrosion rates calculated using the ESSA computed with the developed model will be 12.34% (±0.46%) less than that of using ESSA obtained by micro-CT.