Item

Uncertainty in the measurement of indoor temperature and humidity in naturally ventilated dairy buildings as influenced by measurement technique and data variability

2017, Hempel, Sabrina, König, Marcel, Menz, Christoph, Janke, David, Amon, Barbara, Banhazi, Thomas M., Estellés, Fernando, Amon, Thomas

The microclimatic conditions in dairy buildings affect animal welfare and gaseous emissions. Measurements are highly variable due to the inhomogeneous distribution of heat and humidity sources (related to farm management) and the turbulent inflow (associated with meteorologic boundary conditions). The selection of the measurement strategy (number and position of the sensors) and the analysis methodology adds to the uncertainty of the applied measurement technique. To assess the suitability of different sensor positions, in situations where monitoring in the direct vicinity of the animals is not possible, we collected long-term data in two naturally ventilated dairy barns in Germany between March 2015 and April 2016 (horizontal and vertical profiles with 10 to 5 min temporal resolution). Uncertainties related to the measurement setup were assessed by comparing the device outputs under lab conditions after the on-farm experiments. We found out that the uncertainty in measurements of relative humidity is of particular importance when assessing heat stress risk and resulting economic losses in terms of temperature-humidity index. Measurements at a height of approximately 3 m–3.5 m turned out to be a good approximation for the microclimatic conditions in the animal occupied zone (including the air volume close to the emission active zone). However, further investigation along this cross-section is required to reduce uncertainties related to the inhomogeneous distribution of humidity. In addition, a regular sound cleaning (and if possible recalibration after few months) of the measurement devices is crucial to reduce the instrumentation uncertainty in long-term monitoring of relative humidity in dairy barns. © 2017 The Authors

Loading...
Thumbnail Image
Item

Evaluation of surface nuclear magnetic resonance-estimated subsurface water content

2011, Müller-Petke, M., Dlugosch, R., Yaramanci, U.

The technique of nuclear magnetic resonance (NMR) has found widespread use in geophysical applications for determining rock properties (e.g. porosity and permeability) and state variables (e.g. water content) or to distinguish between oil and water. NMR measurements are most commonly made in the laboratory and in boreholes. The technique of surface NMR (or magnetic resonance sounding (MRS)) also takes advantage of the NMR phenomenon, but by measuring subsurface rock properties from the surface using large coils of some tens of meters and reaching depths as much as 150 m. We give here a brief review of the current state of the art of forward modeling and inversion techniques. In laboratory NMR a calibration is used to convert measured signal amplitudes into water content. Surface NMR-measured amplitudes cannot be converted by a simple calibration. The water content is derived by comparing a measured amplitude with an amplitude calculated for a given subsurface water content model as input for a forward modeling that must account for all relevant physics. A convenient option to check whether the measured signals are reliable or the forward modeling accounts for all effects is to make measurements in a well-defined environment. Therefore, measurements on top of a frozen lake were made with the latest-generation surface NMR instruments. We found the measured amplitudes to be in agreement with the calculated amplitudes for a model of 100 % water content. Assuming then both the forward modeling and the measurement to be correct, the uncertainty of the model is calculated with only a few per cent based on the measurement uncertainty.

Loading...
Thumbnail Image
Item

Mobility particle size spectrometers: Calibration procedures and measurement uncertainties

2017, Wiedensohler, A., Wiesner, A., Weinhold, K., Birmili, W., Hermann, M., Merkel, M., Müller, T., Pfeifer, S., Schmidt, A., Tuch, T., Velarde, F., Quincey, P., Seeger, S., Nowak, A.

Mobility particle size spectrometers (MPSS) belong to the essential instruments in aerosol science that determine the particle number size distribution (PNSD) in the submicrometer size range. Following calibration procedures and target uncertainties against standards and reference instruments are suggested for a complete MPSS quality assurance program: (a) calibration of the CPC counting efficiency curve (within 5% for the plateau counting efficiency; within 1 nm for the 50% detection efficiency diameter), (b) sizing calibration of the MPSS, using a certified polystyrene latex (PSL) particle size standard at 203 nm (within 3%), (c) intercomparison of the PNSD of the MPSS (within 10% and 20% of the dN/dlogDP concentration for the particle size range 20–200 and 200–800 nm, respectively), and (d) intercomparison of the integral PNC of the MPSS (within 10%). Furthermore, following measurement uncertainties have been investigated: (a) PSL particle size standards in the range from 100 to 500 nm match within 1% after sizing calibration at 203 nm. (b) Bipolar diffusion chargers based on the radioactive nuclides Kr85, Am241, and Ni63 and a new ionizer based on corona discharge follow the recommended bipolar charge distribution, while soft X-ray-based charges may alter faster than expected. (c) The use of a positive high voltage supply show a 10% better performance than a negative one. (d) The intercomparison of the integral PNC of an MPSS against the total number concentration is still within the target uncertainty at an ambient pressure of approximately 500 hPa. Copyright © 2018 Published with license by American Association for Aerosol Research.

Loading...
Thumbnail Image
Item

Comparison and uncertainty evaluation of two centrifugal separators for microplastic sampling

2021, Hildebrandt, Lars, Zimmermann, Tristan, Primpke, Sebastian, Fischer, Dieter, Gerdts, Gunnar, Pröfrock, Daniel

For commonly applied microplastic sampling approaches based on filtration, high throughput and no size-discrimination are conflicting goals. Therefore, we propose two efficient centrifugal separators for small microplastic sampling, namely the utilization of a hydrocyclone as well as a continuous flow centrifuge. Thorough method optimization was followed by application in an extensive sampling study to investigate the separators' retention behavior for particulate plastics from estuarine waters. Microplastic concentrations ranged from 193 to 2072 particles m-3. The most dominant identified polymer types were polypropylene, acrylates, polyvinyl chloride and polyethylene. More than 95% of particles were < 100 µm. For the first time in microplastic research, an expanded uncertainty was calculated according to the "Guide to the expression of Uncertainty in Measurement" (JCGM 100:2008). Bottom-up uncertainty evaluation revealed the different sampling methods (~ 44%), sample replicates (~ 26%) and the different detection techniques (~ 16%) as the major sources of uncertainty. Depending on the number of particles detected in the samples, the relative expanded uncertainty (Urel (k = 2)) ranged from 24% up to > 200% underpinning tremendous importance of sound uncertainty evaluation. Our results indicate that scientist should rethink many "observed patterns" in the literature due to being insignificant and herewith not real.