  • Item
    The second ACTRIS inter-comparison (2016) for Aerosol Chemical Speciation Monitors (ACSM): Calibration protocols and instrument performance evaluations
    (Philadelphia, Pa.: Taylor & Francis, 2019) Freney, Evelyn; Zhang, Yunjiang; Croteau, Philip; Amodeo, Tanguy; Williams, Leah; Truong, François; Petit, Jean-Eudes; Sciare, Jean; Sarda-Esteve, Roland; Bonnaire, Nicolas; Arumae, Tarvo; Aurela, Minna; Bougiatioti, Aikaterini; Mihalopoulos, Nikolaos; Coz, Esther; Artinano, Begoña; Crenn, Vincent; Elste, Thomas; Heikkinen, Liine; Poulain, Laurent; Wiedensohler, Alfred; Herrmann, Hartmut; Priestman, Max; Alastuey, Andres; Stavroulas, Iasonas; Tobler, Anna; Vasilescu, Jeni; Zanca, Nicola; Canagaratna, Manjula; Carbone, Claudio; Flentje, Harald; Green, David; Maasikmets, Marek; Marmureanu, Luminita; Cruz Minguillon, Maria; Prevot, Andre S.H.; Gros, Valerie; Jayne, John; Favez, Olivier
    This work describes results obtained from the 2016 Aerosol Chemical Speciation Monitor (ACSM) intercomparison exercise performed at the Aerosol Chemical Monitor Calibration Center (ACMCC, France). Fifteen quadrupole ACSMs (Q_ACSM) from the European Research Infrastructure for the observation of Aerosols, Clouds and Trace gases (ACTRIS) network were calibrated using a new procedure that acquires calibration data under the same operating conditions as those used during sampling and hence gets information representative of instrument performance. The new calibration procedure notably resulted in a decrease in the spread of the measured sulfate mass concentrations, improving the reproducibility of inorganic species measurements between ACSMs as well as the consistency with co-located independent instruments. Tested calibration procedures also allowed for the investigation of artifacts in individual instruments, such as the overestimation of m/z 44 from organic aerosol. This effect was quantified by the m/z (mass-to-charge) 44 to nitrate ratio measured during ammonium nitrate calibrations, with values ranging from 0.03 to 0.26, showing that it can be significant for some instruments. The fragmentation table correction previously proposed to account for this artifact was applied to the measurements acquired during this study. For some instruments (those with high artifacts), this fragmentation table adjustment led to an “overcorrection” of the f44 (m/z 44/Org) signal. This correction based on measurements made with pure NH4NO3, assumes that the magnitude of the artifact is independent of chemical composition. Using data acquired at different NH4NO3 mixing ratios (from solutions of NH4NO3 and (NH4)2SO4) we observe that the magnitude of the artifact varies as a function of composition. Here we applied an updated correction, dependent on the ambient NO3 mass fraction, which resulted in an improved agreement in organic signal among instruments. This work illustrates the benefits of integrating new calibration procedures and artifact corrections, but also highlights the benefits of these intercomparison exercises to continue to improve our knowledge of how these instruments operate, and assist us in interpreting atmospheric chemistry. © 2019, © 2019 Author(s). Published with license by Taylor & Francis Group, LLC.
  • Item
    An electron beam profile instrument based on FBGs
    (Basel : MDPI AG, 2014) Sporea, D.; Stǎncǎlie, A.; Becherescu, N.; Becker, M.; Rothhardt, M.
    Along with the dose rate and the total irradiation dose measurements, the knowledge of the beam localization and the beam profile/energy distribution in the beam are parameters of interest for charged particle accelerator installations when they are used in scientific investigations, industrial applications or medical treatments. The transverse profile of the beam, its position, its centroid location, and its focus or flatness depend on the instrument operating conditions or on the beam exit setup. Proof-of-concept of a new type of charged particle beam diagnostics based on fiber Bragg gratings (FBGs) was demonstrated. Its operating principle relies on the measurement of the peak wavelength changes for an array of FBG sensors as function of the temperature following the exposure to an electron beam. Periodically, the sensor irradiation is stopped and the FBG are force cooled to a reference temperature with which the temperature influencing each sensor during beam exposure is compared. Commercially available FBGs, and FBGs written in radiation resistant optical fibers, were tested under electron beam irradiation in order to study their possible use in this application.