Sources and mixing state of size-resolved elemental carbon particles in a European megacity: Paris

dc.bibliographicCitation.firstPage1681eng
dc.bibliographicCitation.issue4eng
dc.bibliographicCitation.lastPage1700eng
dc.bibliographicCitation.volume12
dc.contributor.authorHealy, R.M.
dc.contributor.authorSciare, J.
dc.contributor.authorPoulain, L.
dc.contributor.authorKamili, K.
dc.contributor.authorMerkel, M.
dc.contributor.authorMüller, T.
dc.contributor.authorWiedensohler, A.
dc.contributor.authorEckhardt, S.
dc.contributor.authorStohl, A.
dc.contributor.authorSarda-Estève, R.
dc.contributor.authorMcGillicuddy, E.
dc.contributor.authorO'Connor, I.P.
dc.contributor.authorSodeau, J.R.
dc.contributor.authorWenger, J.C.
dc.date.accessioned2017-11-17T00:53:15Z
dc.date.available2019-06-26T17:18:08Z
dc.date.issued2012
dc.description.abstractAn Aerosol Time-Of-Flight Mass Spectrometer (ATOFMS) was deployed to investigate the size-resolved chemical composition of single particles at an urban background site in Paris, France, as part of the MEGAPOLI winter campaign in January/February 2010. ATOFMS particle counts were scaled to match coincident Twin Differential Mobility Particle Sizer (TDMPS) data in order to generate hourly size-resolved mass concentrations for the single particle classes observed. The total scaled ATOFMS particle mass concentration in the size range 150–1067 nm was found to agree very well with the sum of concurrent High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS) and Multi-Angle Absorption Photometer (MAAP) mass concentration measurements of organic carbon (OC), inorganic ions and black carbon (BC) (R2 = 0.91). Clustering analysis of the ATOFMS single particle mass spectra allowed the separation of elemental carbon (EC) particles into four classes: (i) EC attributed to biomass burning (ECbiomass), (ii) EC attributed to traffic (ECtraffic), (iii) EC internally mixed with OC and ammonium sulfate (ECOCSOx), and (iv) EC internally mixed with OC and ammonium nitrate (ECOCNOx). Average hourly mass concentrations for EC-containing particles detected by the ATOFMS were found to agree reasonably well with semi-continuous quantitative thermal/optical EC and optical BC measurements (r2 = 0.61 and 0.65–0.68 respectively, n = 552). The EC particle mass assigned to fossil fuel and biomass burning sources also agreed reasonably well with BC mass fractions assigned to the same sources using seven-wavelength aethalometer data (r2 = 0.60 and 0.48, respectively, n = 568). Agreement between the ATOFMS and other instrumentation improved noticeably when a period influenced by significantly aged, internally mixed EC particles was removed from the intercomparison. 88% and 12% of EC particle mass was apportioned to fossil fuel and biomass burning respectively using the ATOFMS data compared with 85% and 15% respectively for BC estimated from the aethalometer model. On average, the mass size distribution for EC particles is bimodal; the smaller mode is attributed to locally emitted, mostly externally mixed EC particles, while the larger mode is dominated by aged, internally mixed ECOCNOx particles associated with continental transport events. Periods of continental influence were identified using the Lagrangian Particle Dispersion Model (LPDM) "FLEXPART". A consistent minimum between the two EC mass size modes was observed at approximately 400 nm for the measurement period. EC particles below this size are attributed to local emissions using chemical mixing state information and contribute 79% of the scaled ATOFMS EC particle mass, while particles above this size are attributed to continental transport events and contribute 21% of the EC particle mass. These results clearly demonstrate the potential benefit of monitoring size-resolved mass concentrations for the separation of local and continental EC emissions. Knowledge of the relative input of these emissions is essential for assessing the effectiveness of local abatement strategies.eng
dc.description.versionpublishedVersioneng
dc.formatapplication/pdf
dc.identifier.urihttps://doi.org/10.34657/1266
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/521
dc.language.isoengeng
dc.publisherMünchen : European Geopyhsical Unioneng
dc.relation.doihttps://doi.org/10.5194/acp-12-1681-2012
dc.relation.ispartofseriesAtmospheric Chemistry and Physics, Volume 12, Issue 4, Page 1681-1700eng
dc.rights.licenseCC BY 3.0 Unportedeng
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/eng
dc.subjectbiomass burningeng
dc.subjectblack carboneng
dc.subjectconcentration (composition)eng
dc.subjectfossil fueleng
dc.subjectmegacityeng
dc.subjectmixingeng
dc.subjectorganic carboneng
dc.subjectparticle sizeeng
dc.subject.ddc550eng
dc.titleSources and mixing state of size-resolved elemental carbon particles in a European megacity: Pariseng
dc.typearticleeng
dc.typeTexteng
dcterms.bibliographicCitation.journalTitleAtmospheric Chemistry and Physicseng
tib.accessRightsopenAccesseng
wgl.contributorTROPOSeng
wgl.subjectGeowissenschafteneng
wgl.typeZeitschriftenartikeleng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
acp-12-1681-2012.pdf
Size:
6.12 MB
Format:
Adobe Portable Document Format
Description: