Replication and Refinement of an Algorithm for Automated Drusen Segmentation on Optical Coherence Tomography

dc.bibliographicCitation.firstPage7395eng
dc.bibliographicCitation.issue1eng
dc.bibliographicCitation.journalTitleScientific Reportseng
dc.bibliographicCitation.lastPage1268eng
dc.bibliographicCitation.volume10eng
dc.contributor.authorWintergerst, M.W.M.
dc.contributor.authorGorgi Zadeh, S.
dc.contributor.authorWiens, V.
dc.contributor.authorThiele, S.
dc.contributor.authorSchmitz-Valckenberg, S.
dc.contributor.authorHolz, F.G.
dc.contributor.authorFinger, R.P.
dc.contributor.authorSchultz, T.
dc.date.accessioned2020-07-21T09:12:27Z
dc.date.available2020-07-21T09:12:27Z
dc.date.issued2020
dc.description.abstractHere, we investigate the extent to which re-implementing a previously published algorithm for OCT-based drusen quantification permits replicating the reported accuracy on an independent dataset. We refined that algorithm so that its accuracy is increased. Following a systematic literature search, an algorithm was selected based on its reported excellent results. Several steps were added to improve its accuracy. The replicated and refined algorithms were evaluated on an independent dataset with the same metrics as in the original publication. Accuracy of the refined algorithm (overlap ratio 36–52%) was significantly greater than the replicated one (overlap ratio 25–39%). In particular, separation of the retinal pigment epithelium and the ellipsoid zone could be improved by the refinement. However, accuracy was still lower than reported previously on different data (overlap ratio 67–76%). This is the first replication study of an algorithm for OCT image analysis. Its results indicate that current standards for algorithm validation do not provide a reliable estimate of algorithm performance on images that differ with respect to patient selection and image quality. In order to contribute to an improved reproducibility in this field, we publish both our replication and the refinement, as well as an exemplary dataset.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://doi.org/10.34657/3697
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/5068
dc.language.isoengeng
dc.publisherBerlin : Springer Natureeng
dc.relation.doihttps://doi.org/10.1038/s41598-020-63924-6
dc.relation.issn2045-2322
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/eng
dc.subject.ddc500eng
dc.subject.otherOCT-basedeng
dc.subject.otherdrusen quantification permitseng
dc.subject.otherAutomated Drusen Segmentationeng
dc.titleReplication and Refinement of an Algorithm for Automated Drusen Segmentation on Optical Coherence Tomographyeng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorTIBeng
wgl.subjectPhysikeng
wgl.typeZeitschriftenartikeleng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Wintergerst_et_ al2020-Replication_and_Refinement_of_an_Algorithm_for_Automated_Drusen.pdf
Size:
1.52 MB
Format:
Adobe Portable Document Format
Description: