Modeling high resolution MRI: Statistical issues with low SNR

dc.bibliographicCitation.seriesTitleWIAS Preprintseng
dc.bibliographicCitation.volume2179
dc.contributor.authorPolzehl, Jörg
dc.contributor.authorTabelow, Karsten
dc.date.accessioned2016-12-13T10:46:52Z
dc.date.available2019-06-28T08:26:26Z
dc.date.issued2015
dc.description.abstractNoise is a common issue for all Magnetic Resonance Imaging (MRI) techniques and obviously leads to variability of the estimates in any model describing the data. A number of special MR sequences as well as increasing spatial resolution in MR experiments further diminish the signal-to-noise ratio (SNR). However, with low SNR the expected signal deviates from its theoretical value. Common modeling approaches therefore lead to a bias in estimated model parameters. Adjustments require an analysis of the data generating process and a characterization of the resulting distribution of the imaging data. We provide an adequate quasi-likelihood approach that employs these characteristics. We elaborate on the effects of typical data preprocessing and analyze the bias effects related to low SNR for the example of the diffusion tensor model in diffusion MRI. We then demonstrate that the problem is relevant even for data from the Human Connectome Project, one of the highest quality diffusion MRI data available so far.eng
dc.description.versionpublishedVersioneng
dc.formatapplication/pdf
dc.identifier.issn2198-5855
dc.identifier.urihttps://doi.org/10.34657/2697
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/3483
dc.language.isoengeng
dc.publisherBerlin : Weierstraß-Institut für Angewandte Analysis und Stochastikeng
dc.relation.issn0946-8633eng
dc.rights.licenseThis document may be downloaded, read, stored and printed for your own use within the limits of § 53 UrhG but it may not be distributed via the internet or passed on to external parties.eng
dc.rights.licenseDieses Dokument darf im Rahmen von § 53 UrhG zum eigenen Gebrauch kostenfrei heruntergeladen, gelesen, gespeichert und ausgedruckt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden.ger
dc.subject.ddc510eng
dc.titleModeling high resolution MRI: Statistical issues with low SNReng
dc.typeReporteng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorWIASeng
wgl.subjectMathematikeng
wgl.typeReport / Forschungsbericht / Arbeitspapiereng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
869244760.pdf
Size:
2.87 MB
Format:
Adobe Portable Document Format
Description: