Preventing Catastrophic Failure of Microfibrillar Adhesives in Compliant Systems Based on Statistical Analysis of Adhesive Strength

dc.bibliographicCitation.firstPage19422eng
dc.bibliographicCitation.issue16eng
dc.bibliographicCitation.journalTitleACS Applied Materials and Interfaceseng
dc.bibliographicCitation.lastPage19429eng
dc.bibliographicCitation.volume13eng
dc.contributor.authorHensel, René
dc.contributor.authorThiemecke, Jonathan
dc.contributor.authorBooth, Jamie A.
dc.date.accessioned2021-11-18T13:55:35Z
dc.date.available2021-11-18T13:55:35Z
dc.date.issued2021
dc.description.abstractAdhesives based on fibrillar surface microstructures have shown great potential for handling applications requiring strong, reversible, and switchable adhesion. Recently, the importance of the statistical distribution of adhesive strength of individual fibrils in controlling the overall performance was revealed. Strength variations physically correspond to different interfacial defect sizes, which, among other factors, are related to surface roughness. For analysis of the strength distribution, Weibull's statistical theory of fracture was introduced. In this study, the importance of the statistical properties in controlling the stability of attachment is explored. Considering the compliance of the loading system, we develop a stability criterion based on the Weibull statistical parameters. It is shown that when the distribution in fibril adhesive strength is narrow, the global strength is higher but unstable detachment is more likely. Experimental variation of the loading system compliance for a specimen of differing statistical properties shows a transition to unstable detachment at low system stiffness, in good agreement with the theoretical stability map. This map serves to inform the design of gripper compliance, when coupled with statistical analysis of strength on the target surface of interest. Such a treatment could prevent catastrophic failure by spontaneous detachment of an object from an adhesive gripper. © 2021 The Authors. Published by American Chemical Society.eng
dc.description.versionpublishedVersioneng
dc.identifier.urihttps://oa.tib.eu/renate/handle/123456789/7355
dc.identifier.urihttps://doi.org/10.34657/6402
dc.language.isoengeng
dc.publisherWashington, DC : ACS Publicationseng
dc.relation.doihttps://doi.org/10.1021/acsami.1c00978
dc.relation.essn1944-8252
dc.rights.licenseCC BY-NC-ND 4.0 Unportedeng
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/eng
dc.subject.ddc540eng
dc.subject.ddc600eng
dc.subject.otheradhesioneng
dc.subject.otherattachment stabilityeng
dc.subject.othermicrofibrillar adhesiveseng
dc.subject.othersystem complianceeng
dc.subject.otherWeibull statisticseng
dc.titlePreventing Catastrophic Failure of Microfibrillar Adhesives in Compliant Systems Based on Statistical Analysis of Adhesive Strengtheng
dc.typeArticleeng
dc.typeTexteng
tib.accessRightsopenAccesseng
wgl.contributorINMeng
wgl.subjectChemieeng
wgl.typeZeitschriftenartikeleng
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
acsami.1c00978.pdf
Size:
3.9 MB
Format:
Adobe Portable Document Format
Description:
Collections